Preparation of high-performance nanofiltration membrane with antioxidant properties

  • Yu, Feiyue;Zhang, Qinglei;Pei, Zhiqiang;Li, Xi;Yang, Xuexuan;Lu, Yanbin
    • Membrane and Water Treatment
    • /
    • 제13권4호
    • /
    • pp.191-199
    • /
    • 2022
  • In industrial production, the development of traditional polyamide nanofiltration (NF) membrane was limited due to its poor oxidation resistance, complex preparation process and high cost. In this study, a composite NF membrane with high flux, high separation performance, high oxidation resistance and simple process preparation was prepared by the method of dilute solution dip coating. And the sulfonated polysulfone was used for dip coating. The results indicated that the concentration of glycerin, the pore size of the based membrane, the composition of the coating solution, and the post-treatment process had important effects on the structure and performance of the composite NF membrane. The composite NF membrane prepared without glycerol protecting based membrane had a low flux, when the concentration of glycerin increased from 5% to 15%, the pure water flux of the composite NF membrane increased from 46.4 LMH to 108.2 LMH, and the salt rejection rate did not change much. By optimizing the coating system, the rejection rate of Na2SO4 and PEG1000 was higher than 90%, the pure water flux was higher than 40 LMH (60psi), and it can withstand 20,000 ppm.h NaClO solution cleaning. When the post treatment processes was adjusted, the salt rejection rate of NaCl solution (250 ppm) reached 45.5%, and the flux reached 62.2 LMH.

Treatment of high-salinity wastewater after the resin regeneration using VMD

  • Gao, Junyu;Wang, Manxiang;Yun, Yanbin
    • Membrane and Water Treatment
    • /
    • 제9권1호
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, vacuum membrane distillation (VMD) was used to treat high-salinity wastewater (concentration about 17%) discharged by chlor-alkali plant after resin regeneration. The feasibility of VMD for the treatment of real saline wastewater by using Polyvinylidene fluoride (PVDF) microporous plate membrane with a pore diameter of $0.2{\mu}m$ was investigated. The effects of critical operating parameters such as feed temperature, velocity, vacuum degree and concentration on the permeate water flux were analyzed. Numerical simulation was used to predict the flux and the obtained results were in good agreement with the experimental data. The results showed that an increase in the operating conditions could greatly promote the permeate water flux which in turn decreased with an increase in the concentration. When the concentration varied from 17 to 25%, the permeate water flux dropped marginally with time indicating that the concentration was not sensitive to the decrease in permeate water flux. The permeate water flux decreased sharply until zero due to the membrane fouling resistance as the concentration varied from 25 to 26%. However, the conductivity of the produced water was well maintained and the average value was measured to be $4.98{\mu}s/cm$. Furthermore, a salt rejection of more than 99.99% was achieved. Overall, the outcome of this investigation clearly indicates that VMD has the potential for treating high-salinity wastewater.

Membrane Filtration Technology for Drinking Water Treatment & Night Soil Treatment

  • Kato, Yasuhiko
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.155-170
    • /
    • 1998
  • 1. The flux for hydrophilic CA membrane is higher than that for hydrophobic PES membrane at any operating conditions. The difference in bpth fluxes becomes greater as the water recovery is lower. 2. Backwash pressure should be more than twice as high as filtration pressure in order to maintain the higher flux. Backwash frequency is independent of the flux when the UF is operated under the same water recovery. 3. The relatively lower crossflow velocity of around 0.1 m/s would be appropriate because of the lower energy consumption per treated water. 4. The membrane fouling occurring at high turbidity and high concentration of organic compounds in raw water can reduce the flux and increase the removal of the organic compounds. 5. It is confirmed by the pilot plant testing that the UF by using the CA membrane module was well applicable to the drinking water treatment.

  • PDF

Hydrophilic Modification of Polypropylene Hollow Fiber Membrane by Dip Coating, UV Irradiation and Plasma Treatment

  • Kim Hyun-Il;Kim Jin Ho;Kim Sung Soo
    • Korean Membrane Journal
    • /
    • 제7권1호
    • /
    • pp.19-27
    • /
    • 2005
  • PP hollow fiber membrane was hydrophilized by EVOH dip coating followed by low temperature plasma treatment and UV irradiation. EVOH coating attained high water flux without any prewetting but its stability did not guaranteed at high water permeation rate. At high water permeation rate, water flux declined gradually due to swelling and delamination of the EVOH coating layer causing pore blocking effect. However, plasma treatment reduces the swelling, which suppress delamination of the EVOH coating layer from PP support result in relieving the flux decline. Also, UV irradiation helped the crosslinking of the EVOH coating layer to enhance the performance at low water permeation rate. FT-IR and ESCA analyses reveal that EVOH dip coating performed homogeneously through not only membrane surface but also matrix. Thermogram of EVOH film modified plasma treatment and W irradiation show that crosslinking density of EVOH layer increased. Chemical modification by plasma treatment and UV irradiation stabilized the hydrophilic coating layer to increase the critical flux of the submerged membrane.

원수의 물리.화학적 특성에 따른 막 분리 공정의 전처리 공정 적용성 평가 (Effect of Pretreatment Process on Hybrid Membrane Filtration Performance)

  • 정철우;손희종;배상대
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.613-619
    • /
    • 2006
  • [ $MIEX^{(R)}$ ]와 응집에 의한 분자량 크기별 제거특성에서는 10 kDa 미만의 유기물질에 대해서는 $MIEX^{(R)}$ 처리가 우수한 제거능을 나타내었으나, 10 kDa 이상의 유기물질은 응집 공정에서 높은 제거능을 가지는 것으로 나타났다. 막의 공극 크기에 대한 투과 flux 실험결과 UF 공정에 비하여 MF 공정에서의 투과 flux 감소율이 낮게 나타나고 있으며, MF 공정에 적용된 전처리 공정중 $MIEX^{(R)}+MF$ 공정의 경우 응집+MF 공정에 비하여 투과 flux 감소율이 낮게 나타나고 있다. $MIEX^{(R)}+UF$ 공정의 경우 입자상 물질의 존재 유무에 상관없이 flux 감소율은 거의 유사하게 나타났으나, 응집+UF 공정의 경우에는 용존성 유기물질만이 존재하는 시수에 비하여 입자상 물질이 존재하는 경우 투과 flux 감소율은 작게 나타났다. 응집 공정의 적용 후 다양한 입도분포 변화가 발생하였으며, pH 7에서 $MIEX^{(R)}$ 입자의 제타전위 측정결과 $MIEX^{(R)}$ 입자의 전하는 평균 -2.3 mV로 나타나 전기화학적으로 입자상 물질의 흡착이 가능하며 $MIEX^{(R)}$가 침전됨에 따라 입자상 물질이 sweep되어 입도분포 변화를 보였다.

하수의 고도처리를 위한 저비용 저에너지의 대체 막을 조합한 생물반응기의 개발 (Advanced Wastewater Treatment using Bioreactor Combined with Alternative Membrane)

  • 김동하
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.25-30
    • /
    • 2005
  • In order to decrease the high costs of membrane process, we have tried to develop two alternatives to membrane; a cartridge type filter and a metal membrane were tested for the high permeation flux with low cost and low energy. This research mainly focused on three points; 1) operation with high permeation flux by using of a cartridge type filter and a metal membrane, 2) removals of the filterable organic materials (FOC) by pretreatments for the membrane fouling control, and 3) advanced wastewater treatment by SMBR process with intermittent aeration and high MLSS. An Intermittently aerated membrane bioreactor using a submerged micro filter (cartridge type) was applied in laboratory scale for the advanced wastewater treatment. To minimize membrane fouling, intermittent aeration was applied inside of the filter with $3.0kg_f/cm^2$. The experiments was conducted for 6 months with three different HRTs (8, 10, 12 hr) and high MLSS of 6,000 and 10,000mg/L. The filtration process could be operated up to 50 days with permeation flux of 500LMH. Regardless of the operating conditions, more than 95% of COD, BOD and SS were removed. Fast and complete nitrification was accomplished, and denitrification was appeared to be the rate-limiting step. More than 75% T-N could be removed due to the endogenous denitrification. T-P removal efficiency was increased to 80% under the condition of MLSS 10,000mg/L.

Optimization of chemical cleaning of discarded reverse osmosis membranes for reuse

  • Jung, Minsu;Yaqub, Muhammad;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2021
  • This study optimized the chemical cleaning process of discarded RO membranes for reuse in less demanding separation processes. The effect of physicochemical parameters, including the temperature, cleaning time, pH of the cleaning solution, and addition of additives, on the cleaning process was investigated. The membrane performance was evaluated by testing the flux recovery rate and salt rejection before and after the cleaning process. High temperatures (45-50 ℃) resulted in a better flux recovery rate of 71% with more than 80% salt rejection. Equal time for acid and base cleaning 3-3 h presented a 72.43% flux recovery rate with salt rejection above 85%. During acid and base cleaning, the best results were achieved at pH values of 3.0 and 12.0, respectively. Moreover, 0.05% concentration of ethylenediaminetetraacetic acid presented 72.3% flux recovery, while 69.2% flux was achieved using sodium dodecyl sulfate with a concentration of 0.5%; both showed >80% salt rejection, indicating no damage to the active layer of the membrane. Conversely, 0.5% concentration of sodium percarbonate showed 83.1% flux recovery and 0.005% concentration of sodium hypochlorite presented 85.2% flux recovery, while a high concentration of these chemicals resulted in oxidation of the membrane that caused a reduction in salt rejection.

표면개질 알루미나막의 증기투과에 의한 알코올의 분리 (Separation of Alcohol/water Mixtures with Surface-modified Alumina Membrane in Vapor Permeation)

  • 이상인;오한기;이광래
    • 멤브레인
    • /
    • 제10권3호
    • /
    • pp.121-129
    • /
    • 2000
  • 높은 선택도와 투과도를 가진 분리막이 요구되지만 선택도가 높은 막은 투과도가 낮은 것이 일반적이다. 본 연구에서는 적절한 선택도를 유지하면서 높은 투과도를 갖는 분리막을 제조하기 위하여 다공성 알루미나막을 실란커플링제로 코팅하였다. 코팅된막에 대한 물의 접촉각은 90$^{\circ}$ 이상이었으며, 큰 소수성을 가짐을 의미하기 때문에 에탄올, 이소프로판올, 부탄을 수용액의 농축을 위한 증기투과실험을 수행하였다. 공급액중의 알코을 농도가 증가함에 따라 투과도가 증가하였으며, 이는 물에 비하여 코팅된 막에 대한 에탄올, 이소프로판올, 부탄올의 친화도가 크기 때문으로 판단된다. 코팅된 알루미나막의 투과도는 고분자막의 투과도에 비하여 20~1000배로 크게 나타났다.

  • PDF

Recent progress in supported liquid membrane technology: stabilization and feasible applications

  • Molinari, Raffaele;Argurio, Pietro
    • Membrane and Water Treatment
    • /
    • 제2권4호
    • /
    • pp.207-223
    • /
    • 2011
  • Supported Liquid Membranes (SLMs) have been widely studied as feasible alternative to traditional processes for separation and purification of various chemicals both from aqueous and organic matrices. This technique offers various advantages like active transport, possibility to use expensive extractants, high selectivity, low energy requirements and minimization of chemical additives. SLMs are not yet used at large scale in industrial applications, because of the low stability. In the present paper, after a brief overview of the state of the art of SLM technology the facilitated transport mechanisms of SLM based separation is described, also introducing the small and the big carrousel models, which are employed for transport modeling. The main operating parameters (selectivity, flux and permeability) are introduced. The problems related to system stabilization are also discussed, giving particular attention to the influence of membrane materials (solid membrane support and organic liquid membrane (LM) phase). Various approaches proposed in literature to enhance SLM stability are also reviewed. Modification of the solid membrane support, creating an additional layer on membrane surface, which acts as a barrier to LM phase loss, increases system stability, but the membrane permeability, and then the flux, decrease. Stagnant Sandwich Liquid Membrane (SSwLM), an implementation of the SLM system, results in both high flux and stability compared to SLM. Finally, possible large scale applications of SLMs are also reviewed, evidencing that if the LM separation process is opportunely carried out (no production of byproducts), it can be considered as a green process.

고 플럭스 MF막의 정수처리 실용화에 관한 연구 (Application of water control by high fiux MF membrane)

  • 황상용
    • 환경위생공학
    • /
    • 제23권2호
    • /
    • pp.55-63
    • /
    • 2008
  • All over the world, the existing process of water purification needs more flocculants and chlorine due to a gradual decline in the quality of source water. Therefore, the problem of the remaining aluminium and DBPs in purified water is on the rise. To solve this problem, the process of membrane filter has recently come into the spotight. This study reaches the following conclusions concerning TMP variation in order to solve the dropping of flux throgh a membrane filter when operating a membrane filter system in the process of water purification. 1. In case that a cohesion-precipitation process was introduced to pre-treatment of a membrane filter, initial TMP was very satisfactory(0.27kg/cm) in producing the constantly safe quality of water, $0.04{\sim}0.1$(mean 0.05) NTU by pouring 2mg/l of PACI(10% $Al_2O_3$) used for the existing process of water purification in high-density turbidity at a dry or flood season and at occurrence of high algae. 2. As flux increased at 0.5m/day.m, TMP increased 0.05 kgf/cm. 3. As filtering, operation mode of PVDF MF membrane filtering was 48 minutes and 1 cycle of back washing was 42 minutes, flux was increased 1.5m/day.m and TMP increased $0.25{\sim}0.27kgf/cm$. Without back washing, TMP increased 0.03 kgf/cm per a cycle.