• 제목/요약/키워드: High energy

검색결과 20,147건 처리시간 0.044초

변압기 손실에 따른 에너지절감 효과 비교 분석 (An Analysis of the Effects of Energy Saving in Connection with Transformer Loss)

  • 최인호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.291-294
    • /
    • 2007
  • Countries in the world are setting up policies to implement anti-global warning measures to actively cope with the Agreement on Climate Change. Rising problems related to energy and environment prompted research and development efforts to highly efficient electric instrument and environmentally friendly products to secure resources and save energy Korea's high dependency on imported energy and its lack in natural resources make it urgently necessary to develop energy efficient instrument and equipment that can save energy. Every household now uses a transformer, which is very important instrument among others. A variety of technologies to manufacture transformers are currently used along with efforts to develop new materials. Development nit of high efficient transformers is called for by the time and has direct economic impact on suppliers and consumers. In addition, it is desirable to install a transformer that is trustworthy, secure, low on loss, anti-incident capable, small, anti-flammable, environmentally friendly, cost-efficient high-frequency resistant and easy for maintenance. To do this, it is necessary to look deeper into a highly efficient transformer that can save energy. This paper will discuss the types and characteristics of various transformers and propose ways to save energy and raise efficiency tv analyzing a environmentally friendly amorphous transformer.

  • PDF

펄스드 $SiH_4-N_2$ 플라즈마를 이용한 SiN 박막의 상온 증착과 굴절률에의 Duty ratio 영향 (Room temperature deposition of SiN thin film using pulsed $SiH_4-N_2$ plasma and the effect of duty ratio on refractive index)

  • 권상희;김병환;우형수;이형구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.25-26
    • /
    • 2009
  • Pulsed-PECVD를 이용하여 상온에서 실리콘 나이트라이드(SiN) 박막을 증착하였다. 본 연구에서는, 60-100%의 duty ratio 변화에 따른 굴절률을 살펴보고, 굴절률에 대한 이온에너지의 영향을 분석했다. RF 소스파워는 900W로 고정하였고 $SiH_4-N_2$를 이용하였다. 이온에너지에 대한 정보는 non-invasive 이온 분석기를 이용하여 수집하였다. 측정된 이온에너지 변수는 high ion energy, low ion energy, high ion energy flux, low ion energy flux이며, 이를 이용해 또 다른 변수인 ion energy flux ratio를 계산하였다. Duty ratio의 감소에 따라 굴절률은 일반적으로 감소하였다. 또한 duty ratio의 감소에 따라 high ion energy는 증가하였다. 한편, 60-80%에서 굴절률은 이온에너지 flux의 비에 강한 의존성을 보였으며, 60%를 제외한 모든 duty ratio 구간에서 굴절률은 Nl에 강하게 영향을 알고 있는 것으로 유추되었다. 굴절률은 1.508와 1.714 사이에서 변화하였다.

  • PDF

휘발성 유기물질의 효율적 열산화를 위한 사이클론 연소시스템 연구 (A Study on Cyclone Combustion System for Efficient Thermal Oxidation of VOC)

  • 현주수;이시훈;임영준;민병무
    • 에너지공학
    • /
    • 제13권2호
    • /
    • pp.112-117
    • /
    • 2004
  • 휘발성 유기물질은 도장공정, 염색, 건조공정 등 화학공정에서 발생하는 저발열량 가스이다 VOCs의 특징은 발열량이 150kcal/㎥ 이하이며 착화를 위한 활성화 에너지가 높고 발생 에너지가 낮다는 것이다. 따라서 연소 안정성은 낮아지고 처리공정은 고에너지 소비공정이 된다. Cyclone연소시스템은 연소기 내에 강한 선회 유동을 만들어서 에너지를 순환시켜 활성화에너지를 낮추어주고 열밀도가 높아 일반적인 swirl 연소 시스템에 비해 고온의 연소온도를 유지할 수 있으며 혼합성을 향상시킨다 본 논문에서는 휘발성 유기물질의 열산화를 위해 최적의 cyclone 연소시스템을 개발하는 것을 목적으로 수행되었으며 특별히 설계된 연소기에서 연소온도와 배가스 조성에 미치는 swirl number의 영향을 정립하였다.

운영실적을 이용한 철도전철화에 따른 에너지 절감효과 분석 (A study on energy saving effectiveness of railway electrification using operation data)

  • 정호성;장동욱;권삼영;한문섭;김진환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.899-904
    • /
    • 2007
  • Improvement projects has been progressed for railway electrification and double track line in the conventional line as well as high speed line for the high speed and large transportation capability of railway. Especially, many variable operation plans are possible such as interaction between high speed line and conventional line and operation of tilting train due to the electrification of the conventional line. Railway electrification is more energy efficient and environmentally-friendly, but it has some problems such as an enormous initial construction and maintenance costs and electrical accidents. Therefore, the more intensive research will be progressed about railway electrification effectiveness for the continuous electrification project. So, we analyzed railway electrification effectiveness about the energy side using annual operation data of electric car and diesel car. The energy side was divided into energy costs and national energy consumption for analyzing electrification effectiveness about entire line and specific line. We verified advantage of energy costs and national energy consumption in this paper and this result will contribute to the progress of the continuous electrification project and the more efficient operation ways in electrification line

  • PDF

원통형 고체산화물 연료전지 스택 제작 및 성능평가 (Fabrication and Performance Evaluation of Tubular Solid Oxide Fuel Cells Stack)

  • 김완제;이승복;송락현;박석주;임탁형;이종원
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.467-471
    • /
    • 2013
  • In present work, optimized the manufacturing process of anode-supported tubular SOFCs cell and stack were studied. For this purpose, we first developed a high performance tubular SOFC cell, and then made electrical connection in series to get high voltage. The gas sealing was established by attaching single cells to alumina jig with ceramic bond. Through these process, we can obtain such high OVP as around 15V, which means that the electrical connection and gas sealing were optimized. Finally we developed a new tubular SOFC stack which shows a maximum power of 65W @ $800^{\circ}C$.

건물에너지효율등급향상을 위한 고효율 건물외피 성능 연구 (Study on High Performance Building Envelope for raising Building Energy Rating)

  • 현종훈;홍성희;박효순;최무혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.801-806
    • /
    • 2008
  • The best plan is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. New insulation materials, which have the high performance and are above insulation standard, have been developed steadily. Because there are not studies on the building energy rating system and economic evaluation considering new insulation materials, these matters should be studied. In result alternatives, which applied 6 high performance material each, influence, reduce the annual heating energy and raise the building energy rating. Applying the vacuum insulation material(Case1,2) and vacuum or triple glazing can retrieves the investment with $120 and $$140{\sim}150$ per barrel each.

  • PDF

분리판의 채널 높이에 따른 1 kWe 급 고체산화물 연료전지 스택 수치 해석 (Numerical Analysis in a 1 kWe SOFC Stack for Variation of the Channel Height in Separators)

  • 윤호원;김영진;이근우;김현진;윤경식;유지행
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.550-556
    • /
    • 2022
  • In this study, the flow uniformity was analyzed by performing numerical analysis on the 1 kWe internal manifold type solid oxide fuel cell stack according to the channel height of the separator. Also, it was examined by varying the fuel utilization rate and oxygen utilization rate. From the calculation results, we found that as the channel height of the separator decreased, the pressure drop increased exponentially. In addition, it was found that as the channel height of the separator decreased, the gas flow resistance inside the unit cell increased, and the flow resistance increased the pressure drop, thereby improving the flow uniformity inside the stack. Finally, the calculation results showed that as the fuel and oxygen utilization increased, the flow uniformity also improved.

1 kWe 급 고체산화물 연료전지 스택에서의 유동 해석 (Numerical Analysis in a 1 kWe SOFC Stack for the Flow Phenomena)

  • 이근우;김영진;윤호원;김현진;윤경식;유지행
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.196-204
    • /
    • 2023
  • This study performed the numerical analysis of the internal flow phenomena of 1 kWe-class solid oxide fuel cell (SOFC) stacks with internal manifold type and planar cells using commercial computational fluid dynamics (CFD) software, Star-CCM+. In particular, the locations where the turbulent phenomena occur inside the SOFC stack were investigated. In addition, the laminar flow model and the standard k-ε turbulent model were used to calculate the SOFC stack, separately. And, the calculation results of both laminar and turbulent models were compared. The calculation results showed that turbulent phenomena occurred mainly in the cathode flow. Especially, the turbulent phenomena were found in the cathode inlet/outlet region, and local turbulence occurred in the end plate near the inlet pipe.

고온 .senter dot. 고습환경이 CFRP 적층 원통부재의 압궤특성에 미치는 영향 (Effects of high temperatures and hygrothermals on the collapse characteristics of CFRP thin-walled laminates)

  • 곽훈이;김정호;양인영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.650-654
    • /
    • 1995
  • In this study, in order to measure energy-absorbing charactistics in collapse test of CFRP thin-walled laminates and interpretate the cause of decreasing age when collapse test is carried out under the environments of high temperatures and hygrothermals, the moisture absorbing behavior according to the variety of orientation angel is observed and collapse characteristics is compared with the influence of high temperatures and hygrothermals. Especially, we supposed to clearly understand reationship between collapse characteristics in proportion to the variety of orientation angel and moisture absorbing. The value of the maximum loading, mean loading,rate of energy absorption energy per unit volume and mass in CFRP thin-walled laminates on the high temperatures and hygrothermals is measured lower than under no moisture absorbing. The maximum collapse loading in dynamic impact test is taken measurement lower than in static collapse test regarding compared with collapse characteristics conformity with the variety of the CFRP circular laminates in high temperatures and hygrothermals. But the absorbed energy per unit mass and volume is almost same and the biggest amount of energy is shown in the CFRP circular laminates with orientation angel of 15 .deg.. Therefore, in the case of use to CFRP circular laminates with axisymmetric mode, CFRP thin-walled structal members with orientation angel of 10 .deg. , 15 . deg. are generally useful.

  • PDF

Monte Carlo shielding evaluation of a CSNS Multi-Physics instrument

  • Liang, Tairan;Shen, Fei;Yin, Wen;Xu, Juping;Yu, Quanzhi;Liang, Tianjiao
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1998-2004
    • /
    • 2019
  • The Multi-Physics (MP) instrument is one of 20 neutron spectrometers planned in the China Spallation Neutron Source (CSNS). This paper presents a shielding calculation for the MP instrument using Monte Carlo codes MCNPX and FLUKA. First, the neutrons that escape from the CSNS decoupled water moderator and are delivered to the beam line of the MP instrument are calculated to use as the source term of the shielding calculation. Then, to validate the calculation method based on multiple variance reduction techniques, a cross check between MCNPX and FLUKA codes is performed by comparing the calculation results of the dose rate distribution on a simplified beam line model. Finally, a complete geometry model of the MP instrument is set up, and the primary parameters for the shielding design are obtained according to the calculated dose rate map considering different worst-case scenarios.