• Title/Summary/Keyword: High efficiency removal

Search Result 1,364, Processing Time 0.03 seconds

Prediction of Coagulation/Flocculation Treatment Efficiency of Dissolved Organic Matter (DOM) Using Multiple DOM Characteristics (다중 유기물 특성 지표를 활용한 용존 유기물질 응집/침전 제거효율 예측)

  • Bo Young Kim;Ka-Young Jung;Jin Hur
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.465-474
    • /
    • 2023
  • The chemical composition and molecular weight characteristics of dissolved organic matter (DOM) exert a profound influence on the efficiency of organic matter removal in water treatment systems, acting as efficiency predictive indicators. This research evaluated the primary chemical and molecular weight properties of DOM derived from diverse sources, including rivers, lakes, and biomasses, and assessed their relationship with the efficiency of coagulation/flocculation treatments. Dissolved organic carbon (DOC) removal efficiency through coagulation/flocculation exhibited significant correlations with DOM's hydrophobic distribution, the ratio of humic-like to protein-like fluorescence, and the molecular weight associated with humic substances (HS). These findings suggest that the DOC removal rate in coagulation/flocculation processes is enhanced by a higher presence of HS in DOM, an increased influence of externally sourced DOM, and more presence of high molecular weight compounds. The results of this study further posit that the efficacy of water treatment processes can be more accurately predicted when considering multiple DOM characteristics rather than relying on a singular trait. Based on major results from this study, a predictive model for DOC removal efficiency by coagulation/flocculation was formulated as: 24.3 - 7.83 × (fluorescence index) + 0.089 × (hydrophilic distribution) + 0.102 × (HS molecular weight). This proposed model, coupled with supplementary monitoring of influent organic matter, has the potential to enhance the design and predictive accuracy for coagulation/flocculation treatments targeting DOC removal in future applications.

Removal of Geosmin by Combined Treatment of PAC and Intermediate Chlorination in the Conventional WTP (표준정수처리공정에서 분말활성탄과 중간염소를 이용한 지오스민 저감방안)

  • Kim, Tae Kyun;Choi, Jae Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • In this study, the effective treatment reducing geosmin and dosage of PAC was suggested when taste & odor compounds flow in. The removal efficiency of geosmin was evaluated with types of chlorination. In case of low geosmin concentration below 25 ng/L, removal efficiency of geosmin was estimated at 46% by combined treatment of pre and intermediate-chlorination. But, in the exclusive intermediate-chlorination treatment, removal efficiency of geosmin was increased to 57%. In the medium geosmin concentration (25~79 ng/L), removal efficiency of geosmin was estimated at 59% by combined treatment. But, in the exclusive intermediate-chlorination treatment, removal efficiency of geosmin was increased to 87%. When high geosmin concentration above 80 ng/L flows in, removal efficiency of geosmin was estimated at 69% by combined treatment. However, in the exclusive intermediate-chlorination treatment, removal efficiency of geosmin was increased to 95%. Then, the exclusive intermediate-chlorination has an important effect on removal of geosmin. After correlation of geosmin concentration and dosage of PAC was analyzed, the coefficient of determination was estimated at 0.96. And, the proper PAC dosage chart was proposed. Also, at a initial occurrence of geosmin, when the combined treatment by intermediate-chlorination and PAC was applied, particle-bound geosmin should be removed continuously. Finally, it is proved that the combined treatment was effective to remove the geosmin by threshold levels as well as to reduce the dosage of PAC.

Electrokinetic Soil Flushing with Nonionic Surfactant for Removal of Phenanthrene

  • 이유진;박지연;김상준;기대정;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.356-359
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are representative hydrophobic organic carbons (HOCs). Surfactant-enhanced electrokinetic (EK) remediation is an innovative in-situ technology that can effectively remove HOCs from low-permeability soils. In this study, the electrokinetic remediation using Tergitol 15-S-12, a nonionic surfactant, was conducted for the removal of phenanthrene from kaolinite. Tergitol 15-S-12 was used at concentrations of 1.5, 2.0, 2.5 and 7.5 g/L to enhance the solubility of phenanthrene. When the surfactant solution was applied to EK system, high electrical potential gradient was maintained and the amount of electroosmotic flow decreased. Removal efficiency of phenanthrene was proportional to the concentration of Tergitol 15-S-12 because the solubility and mobility of phenanthrene was enhanced by surfactant micelle. Therefore, the suitable concentration of nonionic surfactant Tergitol 15-S-12 is expected to improve the removal efficiency of PAHs in EK remediation.

  • PDF

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.3
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF

Pollutant Removal Efficiency in Oxidation Pond with Filamentous Algae Mat (사상성 조류매트 산화지의 수질정화효율)

  • Choi, Sun-Hwa;Jang, Jeong-Ryeol;Ahn, Yeul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.655-660
    • /
    • 2005
  • This study was carried out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat(FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow. The removal efficiencies of COD, SS, T-N and T-P in Oxidation Pond with Filamentous Algae Mat were -2.5%, 84.7%, 63.9% and 89.2%, respectively. The removal efficiencies of T-N and T-P which are nutrients index were high. Results of this study would help us to determine the possibility of using the water treatment on the contaminated small rural streams.

  • PDF

An Improved Treatment of Animal Wastewater

  • Oh, I.H.;Kim, B.S.;Lee, S.R.;W.J.Maeng
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1379-1394
    • /
    • 1993
  • The purpose of this study is to examine the purification efficiency of the septic tank method which has been applied by the most of Korean livestock farms, in terms of anaerobic and aerobic treatment. Except several days in summer, BOD of effluent shows 1,500 -3,000 ppm by anaerobic process. In most cases , it exceeds according to the seasons show an increase by decrease of temperature. The removal effect on T-N is hardly found. The suspended solids contents of effluent are reduced to the level of 50-90%. Although BOD contents of effluent are kept high in the beginning, the removal rate of BOD shows 80 percent in the latter half by the aerobic treatment . The removal efficiency of total nitrogen does not appear through the experimental period, but the contents of T-N are not increased in the aerobic process unlike in the anaerobic process. The total phosphorous contents in effluent keep a constant level of 14 mg/L in average. The removal rate of phosphorous shows 91 percent i the last stage.

  • PDF

A Study on the Treatment of Paper Mill Wastewater with the Addition of High Thermal Microbial Inoculants (고온성 종균제를 이용한 제지폐수 처리)

  • 이성호;임택준;조준형
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.54-60
    • /
    • 2002
  • The Wastewater of toilet paper mill recycling recovered milk carton was used as a raw material for this study. According to the actual mill conditions, hydraulic retention time was adjusted to 12 hours and F/M (Food/Micro-organism) ratio was adjusted to 0.23. Temperature of aeration basin was varied from 2$0^{\circ}C$ to 5$0^{\circ}C$. The change of Micro-organisms and removal efficiency of pollutant were investigated at the varied temperature of basin. Aeration basin using high thermal microbial inoculants showed more removal efficiency of SS, COD than aeration basin using conventional microbial inoculants at high temperature. Floc consolidation of aeration basin using high thermal microbial inoculants added sludge was better than that of sludge from aeration basin using conventional microbial inoculants.

Treatment of Polyester Weight Loss Wastewater Using Strains Degrading Ethylene Glycol and Terephthalic Acid (Ethylene Glycol과 Terephthalic Acid 분해균주를 이용한 감량가공폐수처리)

  • 서승교
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.43-48
    • /
    • 2001
  • Terephthalic acid and ethylene glycol resulting form the weight-reduction process of polyester make trouble in the operation of activated sludge process. Also, polyester weight loss wastewater shows high pH, high organic strength and wide variation of organic loading. Therefore, this study was conducted in order to improve treatment efficiency by activated sludge process with Pseudomonas sp degrading components of polyester weight loss wastewater. The CO $D_{Mn}$ and BO $S_{5}$ of the waste wastewater were 560~3,000 mg/$\ell$ and 8000~3,000 mg/$\ell$, respectively. pH was 11.8~12.3. COD removal efficiency by activated sludge-coagulation process with Pseudomonas sp was 94.1~95.8% for 35 hr of hydraulic retention time. Total organic carbon removal efficiency was 97.1%. Ethylene glycol and terephthalic acid in the wastewater were completely degraded during 32 hr of hydraulic retention time.e.

  • PDF

A Study on Anaerobic Sewage Treatment Using a Fluidized Bed Reactor (유동상 반응조를 이용한 하수의 혐기성 처리에 관한 연구)

  • Ye, Hyoung-Young;Lee, Eun-Young;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • Anaerobic sewage treatment is drawing attentions due to high energy consumptions and sludge production associated with aerobic treatment. This study evaluates the treatment characteristics and energy balance of a fluidized bed reactor (FBR) for treating domestic sewage at $20^{\circ}C{\sim}25^{\circ}C$ for 245 days. Sewage fed to the FBR was a primary clarifier effluent of a domestic sewage treatment plant with COD of 99-301 mg/L and $BOD_{5}$ of 37-149 mg/L. Effluent $SBOD_{5}$ and its removal efficiency at HRT of 1~3 h were 6~15 mg/L and 73.4~85.5%, respectively, achieving high removal efficiency for soluble organic substances even at short HRTs. COD removal efficiency and its effluent concentration were 53.8~75.9% and 51~83 mg/L, respectively. The energy production potential from gaseous methane was 0.009-0.028 kWh/$m^{3}$, which satisfies the energy required for the FBR operation.

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.