• Title/Summary/Keyword: High efficiency level

Search Result 1,878, Processing Time 0.031 seconds

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

EFFECTS OF CUTTING FREQUENCY AND NITROGEN FERTILIZATION ON DRY MATTER YIELD OF REED CANARYGRASS (Phalaris arundinacea L.) IN UNCULTIVATED RICE PADDY

  • Lee, J.S.;Ahn, J.H.;Jo, I.H.;Kim, D.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.6
    • /
    • pp.737-741
    • /
    • 1996
  • Dry matter yield of reed canarygrass was investigated in uncultivated rice paddy in Korea, and an attempt was made to estimate the most economic and efficient cutting frequency and rates of nitrogen (N) fertilization, for increased production of reed canarygrass. Total dry matter yields of reed canarygrass per year were 7.4-15.7, 8.5-16.1, and 7.5-13.4 tons/ha in 3, 4, and 5 cutting frequencies, respectively, and over the N treatments of 0-120 kg N/ha/cut. When cut 3 or 5 times annually, the 2nd cut produced the highest proportion of total yield at 38.4 and 33.0%, respectively, when cut 4 times the 3rd cut was highest (38.3%). The ranges of economic N level, limiting N level and efficiency of dry matter production were 243.3-293.0, 387.2, and 14.6 kg DM/kg N, respectively. These indicators were particularly low for the 5 cutting frequency possibly because of the unusually high temperature in the summer season. The best cutting frequency for the dry matter production of reed canarygrass in 1994 was 3 per year because of the higher efficiency of dry matter production.

A Study on the Operating Control of a Heat Pump System with Screw Compressors (스크류 열펌프 시스템의 운전제어 방안에 관한 연구)

  • Park, Jun-Tark;Lee, Young-Soo;Kim, Jiyoung;Chae, Kyu-Jung;Yang, Hee-Jung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.168-172
    • /
    • 2013
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump system, which will be used for district heating and cooling. In this study, two issues of the system operating control were investigated. The first issue is the mode switching control from 1-stage to 2-stage. A stable 2-stage heating operation is guaranteed, only if the load-side water inlet temperature is over a certain value, where the 1-stage heating operation should be done first from a cold start. The second issue is oil level control. An oil shortage problem in the low stage compressor, which depends on the degree of suction superheat, was solved by a proper oil level control scheme.

Availability of 2-Dimensional Vector Magnetic Property for High Flux Density Machines

  • Enokizono Masato
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.1-5
    • /
    • 2005
  • The vector magnetic property is defined as the relationship between the magnetic field strength vector H and the magnetic flux density vector B. It is very important for the development of high efficiency and the high-density electric machines. The electrical steel sheet for the machine core shows the remarkable vector behavior by the high magnetic flux density level. In this paper, the magnetic characteristic analysis using E&S2 model is introduced as the useful technology for the design and development.

A Study on the Three-Level Converter using Primary Auxiliary Circuit (1차측 보조회로를 이용한 Three-Level 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Cho, Kyu-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.972-981
    • /
    • 2008
  • A New ZVS(Zero Voltage Switching) and ZVZCS(Zero Voltage and Zero Current Switching) Three-Level Converter is proposed. The proposed converter presented in this paper used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the all switch. A primary auxiliary circuit, which consists of one coupled inductor, is added in the primary to provide ZVZCS conditions to primary switches. Many advantages including simple circuit topology high efficiency, and low cost make this converter attractive for high power applications. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 2kW(27V, 74A) 40 kHz IGBT based experimental circuit.

A study on the Design of a stable Substrate Bias Generator for Low power DRAM's (DRAM 의 저전력 구현을 위한 안정한 기판전압 발생기 설계에 관한 연구)

  • 곽승욱;성양현곽계달
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.703-706
    • /
    • 1998
  • This paper presents an efficient substrate-bias generator(SBG)for low-power, high-density DRAM's The proposed SBG can supply stable voltage with switching the supply voltage of driving circuit, and it can substitude the small capacitance for the large capacitance. The charge pumping circuit of the SBG suffere no VT loss and is to be applicable to low-voltage DRAM's. Also it can reduce the power consumption to make VBB because of it's high pumping efficiency. Using biasing voltage with positive temperature coefficient, VBB level detecting circuit can detect constant value of VBB against temperature variation. VBB level during VBB maintaining period varies 0.19% and the power dissipation during this period is 0.16mw. Charge pumping circuit can make VBB level up to -1.47V using VCC-1.5V, and do charge pumping operation one and half faster than the conventional ones. The temperature dependency of the VBB level detecting circuit is 0.34%. Therefore the proposed SBG is expected to supply a stable VBB with less power consumption when it is used in low power DRAM's.

  • PDF

A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range (차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터)

  • 송인호;유상봉;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

Interface of EDI System and VPN with IPSec and L2TP (IPSec과 L2TP를 이용한 VPN과 EDI 시스템의 연동)

  • Choe Byeong-Hun;Lee Geon-Ho;Jeong Byeong-Hui
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.357-360
    • /
    • 2004
  • Electronic Data Interchange (EDI) between a number of companies goes on increasing on the internet. Although a conventional EDI system reduces business process efforts, time, resources, etc., important information is easily and frequently exposed by well trained hackers and crackers, which inflict a severe loss on the company and even put the company under a crisis. This study integrates the conventional EDI system and Virtual Private Net (VPN) to maximize an overall efficiency of speed and security in data transaction by the level of importance. The EDI system properly interfaced to IPSec and L2TP of VPN allows us to select two modes: the one focuses on a high speed with a low or a medium level security or the other does on a high level security with a low or a medium level speed. Both the company and the end users get a lot of tangible and intangible advantages by integrating the EDI system and VPN.

  • PDF

High Gain and High Efficiency Class-E Power Amplifier Using Controlling Drain Bias for WPT (드레인 조절회로를 이용한 무선전력전송용 고이득 고효율 Class-E 전력증폭기 설계)

  • Kim, Sanghwan;Seo, Chulhun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.41-45
    • /
    • 2014
  • In this paper, a high-efficiency power amplifier is implemented by using a drain bias control circuit operated at low input power for WPT(Wireless Power Transfer). Adaptive bias control circuit was added to high-efficiency class-E amplifier. It was possible to obtain the overall improvement in efficiency by adjusting the drain bias at low input power. The proposed adaptive class-E amplifier is implemented by using the input and output matching network and serial resonant circuit for improvement in efficiency. Drain bias control circuit consists of a directional coupler, power detector, and operational amplifier for adjusting the drain bias according to the input power. The measured results show that output powers of 41.83 dBm were obtained at 13.56 MHz. At this frequency, we have obtained the power added efficiency(PAE) of 85.67 %. It was confirmed increase of PAE of an average of 8 % than the fixed bias from the low input power level of 0 dBm ~ 6 dBm.

A Study of the Work Efficiency in the High Altitude according to Climatic Elements (지역별 기후에 따른 고소작업가능률 산정 - 서울, 인천, 부산 지역을 중심으로 -)

  • Lee, Hyun-Soo;Cho, Sung-Jun;Park, Moon-Seo;Hwang, Sung-Joo;Kim, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.3
    • /
    • pp.67-77
    • /
    • 2012
  • O Having a highly reliable plan for the process and estimating an accurate construction period during the early stages of a construction project can prevent falsifying the plan and reduce the occurrence of construction delays. Moreover, it allows a succession of swift and accurate decisions to happen. The difficulty in obtaining an accurate estimate of the construction period is especially prominent in high-rise building projects because the works involved are very complicated and costly. As such, it is important that research is done to find out the impacts a reliable plan and good estimate of the construction period can bring with regards to the monthly work efficiency and success of a high-rise building project. However, due to the difference in climatic conditions at high altitude and surface level, the current way of calculating work efficiency in a typical project is inaccurate for a high-rise building project. With that, this paper aims to compute the work efficiency with height, taking into consideration the change in climatic elements at different working heights. A comparison of the results according to the climatic features of each city can also be done in this paper. According to the results calculated in work altitudes, the work efficiency in Busan falls the most. On the other hands, the work efficiency in Seoul falls the least. The reason these results are shown is the influence of wind speed at high altitude. The estimation of work efficiency at high altitude would be used for estimating construction period, feasibility studies, and selecting a city of high-rise building projects.