• Title/Summary/Keyword: High background radiation area

Search Result 32, Processing Time 0.02 seconds

Incidence of Micronuclei in Lymphocytes of Cattle in the High Background Radiation Area (자연방사선 고준위 지역 사육 소의 림프구 미소핵 발생 평가)

  • Lee, Hae-June;Kang, Chang-Mo;Kim, Se-Ra;Moon, Chang-Jong;Kim, Jong-Choon;Kim, Ill-Hwa;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.417-422
    • /
    • 2006
  • Cytogenetic and hematological analysis was performed in peripheral blood obtained from cattle bred in the high background radiation areas (HBRA, Goesan-gun, Cheongwon-gun, Boeun-gun) and a control area. The frequencies of gamma-ray induced micronuclei (MN) in the cytokinesis-blocked (CB) lymphocytes at several doses were measured in 3 cattle. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the bovine lymphocytes exposed in vitro to radiation over the range from 0 mGy to 1,969 mGy. The measurements performed after irradiation showed dose-related increases in the MN frequency in each donors. The results were analyzed using a linear-quadratic model with a line of best fit of $y=(0.0583{\pm}0.0137)D+(0.0366{\pm}0.0081)D^2+(0.0093{\pm}0.0015)$ (y=number of MN/CB cells and D=irradiation dose in Gy). MN rates per 1,000 CB lymphocytes of cattle from the Goesan-gun, Cheongwon-gun, Boeun-gun and the control area were $6.50{\pm}2.72,\;9.00{\pm}4.50,\;10.89{\pm}4.23\;and\;9.60{\pm}4.70$, respectively. The MN frequencies of CB lymphocytes from cattle bred in 4 areas mean that the values are within the background variation in this experiment. The MN frequencies and hematological values were similar regardless of whether the cattle were bred in the HBRA or the control area.

Incidence of micronuclei in lymphocytes of pig in the high background radiation area (Cheongwon-gun and Boeun-gun) (국내 자연 방사선 고준위 지역(청원군, 보은군) 사육 돼지의 림프구 미소핵 발생 평가)

  • Lee, Hae-June;Kang, Chang-Mo;Kim, Se-Ra;Lee, Jin-Hee;Kim, Joong-Sun;Kim, Jong-Choon;Kim, Ill-Hwa;Kim, Tae-Hwan;Ryu, Si-Yun;Jo, Sung-Kee;Choi, Soo-Yong;Kim, Sung-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.469-475
    • /
    • 2005
  • Cytogenetic and hematological analysis was performed in peripheral blood obtained from pigs bred in the high background radiation areas (HBRA) (Cheongwon-gun and Boeun-gun) and a control area. The frequencies of gamma-ray induced micronuclei (MN) in the cytokinesis-blocked (CB) lymphocytes at several doses were measured in three pigs. An estimated dose of radiation was calculated by a best fitting linear-quadratic model based on the radiation-induced MN formation from the swine lymphocytes exposed in vitro to radiation over the range from 0 mGy to 1,969 mGy. The measurements performed after irradiation showed dose-related increases in the MN frequency in each donors. The results were analyzed using a linear-quadratic model with a line of best fit of $y=0.0005404D^2+0.04237D+0.00833$ [y = number of MN/cytokinesis-blocked (CB) cells and D = irradiation dose in Gy]. MN rates per 1,000 CB lymphocytes of pig from the HBRA (Cheongwon-gun, Boeun-gun) and the control area were $6.70{\pm}2.36$, $9.00{\pm}3.50$ and $11.00{\pm}2.98$, respectively. The MN frequencies of CB lymphocytes from pigs bred in three areas means that the values are within the background variation in this experiment. The MN frequencies and hematological values were similar regardless of whether the pigs were bred in the HBRA or the control area.

Relationship between Hospital Safety Symbol Shapes and Memory (병원 안전 심볼의 형태와 기억과의 관계)

  • Seok-Hwan Bae;Myung-Chul Park;Jae-Sang You;Yong-Gwon Kim;Cheul-Ho Ryoo;Dong-Hyun Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.115-122
    • /
    • 2023
  • The purpose of this study was to examine the association between the shapes and colors of emergency exit symbols, magnetic field warning symbols, and radiation zone symbols used in hospitals for staff and patient safety and their effects on cognitive memory. The hippocampal region's signal intensity(SI) was analyzed using fMRI. The Symbol 2 (1.75±0.54) with a green background had the highest signal intensity (SI) for emergency exits, according to the findings. The black symbol 2 (1.60±0.51) with a yellow background had the highest signal intensity (SI) for the magnetic field warning symbol, followed by the black symbol 1 (1.59±0.65) with an orange background. The black symbol 2 (1.59±0.59) with a yellow background and the black symbol 3 (1.58±0.52) with an orange background had the low signal intensity with slight differences as for the radiation zone symbols. In conclusion, it was determined that the signal intensity of the black symbol with a yellow background was the highest in the magnetic field area and radiation area. This implies that symbols with a high signal intensity (SI) must be utilized intensively. To ensure that the correct meaning of the symbols is communicated in the future, they must also be utilized regularly and continually in disaster safety education.

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.

Recent Trend of Occupational Exposure to Ionizing Radiation in Korea, 2015-2019

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.213-217
    • /
    • 2021
  • Background: Radiation exposure can occur as a result of occupational activities utilizing sources of radiation. The average level of occupational exposure is generally similar to the global average, but some workers receive more than this. In this study, the occupational exposure data for workers in Korea to check the recent trend of radiation exposure. Materials and Methods: The data collection and analysis are carried out by two separate periods based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) survey. One is the year 2003 to 2014 for a recent survey, and the other is 2015 to 2019. All available data were collected by annual reports from radiation dose registry organizations. Results and Discussion: The annual dose over the record level to the total workers did not change much compared with the total increasing number of workers in this period. The dose to the nuclear fuel cycle field has a tendency to decrease. It resulted from the efforts of radiation dose reduction with high technology introduced to this area. Also, it is important result that the radiation dose to the workers in radiography is remarkably reduced. Conclusion: The number of radiation workers and average doses were analyzed for occupational categories in Korea. It still needs cooperative efforts between the dose registry organizations for the efficient dose management of Korean radiation workers.

An inquiry into dental personnel's Knowledge, attitude and behavior about the defense against dental radiation (치과 의료기관 종사자의 방사선 방어에 대한 지식, 태도 및 행위)

  • Kim, Sun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.15-29
    • /
    • 2004
  • The purpose of this study was to understand the relationship among knowledge, attitude, and behavior of dental personnel about the defense against dental radiation according to general features, and help them recognize the importance of defense against dental radiation. A questionnaire survey of 187 dental personnel who were working in 121 medical institutions such as university hospitals, general hospitals, hospitals, clinics, and public health centers in Seoul area was conducted from December 2002 to January 2003. Study findings are as follows: 1. The average knowledge score for the defense of radiation was 9.51(full score=14): By the demographic features, the know level for the defense of radiation was appeared to be different with the occupational category, age, academic background, workplace, year of working, and whether having the education of radiation or not. By questionnaire items, the knowledge for the defense of radiation was high in general, but for the item. 'the average amount of being bombed with radiation according occupations cannot be over 20mSv in a year for prescribed 5 years'. it was 18.7%: and for the item. 'the longer the length between focus and film. the less the amount of skin exposure', it was 40.6%. showing less knowledge for these two items. 2. The average attitude score for the defense of radiation was 64.24 (full score=75): By the demographic features, the attitude score was higher with respondents who were 31-35 years old. 11-15 years of working. and having radiation education. The attitude score by questionnaire items was generally high for all the items. 3. The average behavior score for the defense of radiation was 45.43: (a) By the demographic features, the behavior score for the defense of radiation was appeared to be higher with respondents who were dentists for occupational category, the aged for age, holding higher diploma for academic background, working in the university hospitals for workplace, and having longer occupational career for the year of working. (b) The behavior score for the defense of radiation by questionnaire items was lower than that of the attitude score for all the items. For the item, 'the amount of X-ray radiation is adjusted according to such conditions as patients' age, radiating areas, and kind of films', the score was 4.03; and for the item, 'Must receive the education of safety management of radiation periodically', the score was 1.73 and it was the lowest one. 4. As for the correlation among the knowledge, attitude, and behavior for the defense of radiation, the higher the level of knowledge and attitude, the higher the level of behavior.

  • PDF

The Effects of Safety Training Involving Non-Destructive Testing Among Students at Specialized Vocational High Schools

  • Lim, YoungKhi;Han, Eun Ok;Choi, YoonSeok
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.98-105
    • /
    • 2017
  • Background: By examining the safety issues involved in on-site training sessions conducted at specialized vocational high schools, and by analyzing the effects of non-destructive testing (NDT) safety training, this study aims to contribute to ensuring the general safety of high school students. Materials and Methods: Students who expressed an interest in participation were surveyed regarding current NDT training practices, as well as NDT safety training. A total of 361 students from 4 schools participated in this study; 37.7% (136 students) were from the Seoul metropolitan area and 62.3% (225 students) were from other areas. Results and Discussion: Of the respondents, 2.2% (8 students) reported having engaged in NDT. As a result of safety training, statistically significant improvements were observed in most areas, except for individuals with previous NDT experience. The areas of improvement included safety awareness, acquisition of knowledge, subjective knowledge levels, objective knowledge levels, and adjustments to existing personal attitudes. Conclusion: Even at absolutely necessary observation-only training sessions, it is crucial that sufficient safety training and additional safety measures be adequately provided.

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

One-Year Continuous Measurement of Outdoor Radon Progeny Concentration in Beijing Area

  • Zhang, Lei;Wang, Yunxiang;Guo, Qiuju
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.95-100
    • /
    • 2020
  • Background: Compared with reported data of radon concentration, data of radon progeny concentration is limited in general, especially in outdoor environment. Materials and Methods: To know both the level and the variation of radon progeny concentration in outdoor environment in Beijing area, one-year continuous measurement with a cycle of 60 minutes was carried out by a step-advanced filter (SAF) monitor for radon progeny measurement. The observation site was located in a park in Eastern Beijing area, and the observation period was from October 17, 2018 to September 29, 2019. Results and Discussion: The equivalent equilibrium concentration (EEC) of radon progeny varies from 0.7 to 19.1 Bq·m-3, with an annual average of 4.9 ± 2.7 Bq·m-3. A clear diurnal variation of EEC, higher in the early morning and lower in the late afternoon, is observed due to the high sensitivity of the SAF monitor. Conclusion: Vertical convection of atmospheric boundary layer is thought to be the main reason of this phenomenon. For annual variation, the lowest monthly average EEC appeared in April, while the highest appeared in November, which might attribute to the atmospheric stability in different seasons.