• 제목/요약/키워드: High Volume Operation

검색결과 332건 처리시간 0.069초

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교 (Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2)

  • 이건희;김상복;박인용;홍기정;이예완;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

국내 경수로형 원자로 냉각재 중의 $^{14}C$ 거동 특성 평가 (Evaluation of $^{14}C$ Behavior Characteristic in Reactor Coolant from Korean PWR NPP's)

  • 강덕원;양양희;박경록
    • 방사성폐기물학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 본 논문은 국내에서 가동되고 있는 3개 로형의 원자로 냉각재로부터 유기 및 무기 $^{14}C$의 특성을 평가하는데 초점을 맞추었다. 주목적은 국내 원전 부지에서 환경으로 방출되는 $^{14}C$에 대한 신뢰할 만 한 특성을 평가하는데 있다. $^{14}C$는 방사성핵종 인벤토리 중 가장 중요한 핵종중의 하나로서 처분장에서의 방출 시나리오에서 가장 중요한 선량 기여 핵종중의 하나이다. $^{14}C$는 반감기가 5,730 년인 순수 베타방출체로써 환경으로의 이동성이 높을 뿐 아니라 생물학적인 유용성이 높다. 최근의 연구결과에 의하면, 유기화합물 형태의 $^{14}C$는 환원환경 하에서 원자로 냉각재내에서 주종을 이루고 있는 것으로 밝혀졌으며 그 외의 유기화합물인 formaldehyde, formic acid 및 acetate도 함께 형성되는 것으로 알려졌다. 그러나 정지화학 처 리 기간인 산성 산화환경 하에서는 산화성 탄소형태로 바뀌면서 $^{14}CO_2$$H^{14}CO_3^-$형으로 바뀌어 지는 것으로 나타났다. 본 연구에서는 원자력발전소의 다양한 처리계통의 시료에 대해 유기 및 무기화학형의 $^{14}C$ 농도를 측정, 평가하였다 원자로 계통 내에서의 $^{14}C$ 인벤토리는 약 3.1 GBq/kg로 나타났으며 냉각재 계통 내에서는 주로 유기화학형 이 주종을 이루고 있었으며 무기화학형은 10% 이내인 것으로 나타났다 용액중의 $^{14}C$ 측정은 기상과 액상으로 분리하여 분석하였다. 정상 운전 중에는 유기화학형의 $^{14}C$가 주종을 이루고 있지만 발전소의 배기구를 통해 방출되는 $^{14}C$의 화학형은 온도, pH, 체적제어탱크의 방출 및 정지화학 처리에 따라 화학형이 달라지고 있는 것으로 나타났다.

  • PDF

측후방융합술을 시행한 요추관협착증 환자의 Critical Pathway 적용효과 (Effects of a Critical Pathway of Posterolateral Fusion in Patients with Lumbar Spinal Stenosis)

  • 박혜옥
    • 간호행정학회지
    • /
    • 제7권2호
    • /
    • pp.265-284
    • /
    • 2001
  • The case management has been applied to improve the quality of care and the cost-effectiveness in the most health care institutions. In a way of case management, the critical pathway(CP) has been executed in many acute care settings, focused on the diagnoses with high cost, high volume, and high risk. This study was conducted to develop a case management program using CP as an intervention of patients with lumbar spinal stenosis for the surgery of posterolateral fusion, and to find out the effects of the critical pathway on the quality of nursing care, patient satisfaction as an outcome of care, length of stay and medical charge, and nurses' job satisfaction. At the same time, patients' functional states were checked with the Oswestry Low Back Pain Index, to show that the CP would not decrease the patients' function compared to the control group. The subjects were 25 control patients with a usual operation of lumbar fusion and 25 experimental patients with CP. They were all female, aged $50s{\sim}70s$, admitted in the Orthopedic surgery ward of a university hospital. Also nurses on the floor using CP were asked to respond to measurement tool of job satisfaction before and after the application of CP, and compared with other nurses on the different wards. Data were analyzed with t-test for continuous variables and chi-square for non-parametric variables in addition to the reliability test of the measurement tools. The results of this study were as followings: 1. Patients' functional states The differences in Oswestry scores of the experimental and control groups assessed at preoperation and at discharge were not statistically significant. The change in scores of the experimental group measured at preoperation and at discharge was larger than that of the control group, however the difference was not statistically significant. The results indicate that the CP did not decrease the patients' functional status. 2. The quality of nursing care The total of quality of nursing care given to the experimental group was better than that of the control group(P=.000). In addition, the experimental group showed better scores of quality of every item of care than the control group(P=.000 -.004). 3. Patient satisfaction Patients of the experimental group were not more satisfied with general care than the control group. But they were more satisfied with discharge care of 'explanation about medication, body posture, and brace application' and 'explanation about the adjustment of daily living and exercise during recovery'(P= .047, P=.028). 4. Nurses' job satisfaction Nurses working with the CP showed more job satisfaction than before the CP introduction(P=.048). But the control group of nurses on a different floor showed no change in job satisfaction at the same period of time. 5. Length of stay and medical charge The mean length of stay of the experimental group was shorter than that of the control group without statistical significance. The charge of medication and treatment of the experimental group were smaller than that of the control group(P=.011, P=.000). The results of the study support that the case management using critical pathway enables to improve the quality of care and job satisfaction, to reduce the medical charge, and consequently to increase satisfaction with care. However, the case management should be instituted focusing on the quality improvement of nursing and the client satisfaction, not just for the purpose of cost-effectiveness of health care facilities.

  • PDF

고농도 질소폐수로부터 암모니아 회수를 위한 다단수직형 암모니아스트리핑조 개발(I) (Development of a Vertical Multi-stage Ammonia Stripping Reactor for Recovering Ammonia from wastewater with High Nitrogen Concentrations(I))

  • 이재명;최홍복
    • 유기물자원화
    • /
    • 제25권2호
    • /
    • pp.41-48
    • /
    • 2017
  • 기존 혐기성 및 호기성 처리에서 우수성이 입증된 E-PFR을 적용한 다단수직형 암모니아 스트리핑조를 개발하고 랩스케일 실험을 수행하였다. 다단수직형 암모니아스트리핑조의 단수별 암모니아성 질소 제거 실험(pH 10, 온도 $35^{\circ}C$, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 단이 없는 반응기는 약 52.5%의 제거율을 나타났으며, 5단 반응기에서는 약 62.6%의 제거율이 나타나 약 10%의 효율 차이가 있는 것으로 확인하였다. pH 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, 온도 $35^{\circ}C$, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 pH 9는 약 42.6%의 제거율을 나타났으며, pH 11에서 약 74.4%의 제거율이 나타났다. 온도 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, pH 10, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 $25^{\circ}C$에서 약 51%의 제거율을 나타났으며, $45^{\circ}C$에서 약 87.2%의 제거율이 나타났다. 공기주입량 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, pH 10, 온도 $35^{\circ}C$의 동일 조건)에서 8시간 경과 후 기액비 $2min^{-1}$에서 약 45.8%의 제거율을 나타났으며, 기액비 $4min^{-1}$에서 약 75%의 제거율이 나타났다. 이러한 결과를 바탕으로 추후 연속 운전 평가를 통해 실증플랜트 설계를 위한 인자 도출에 활용하고자 한다.

모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발 (Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste)

  • 최종서;유영환;박승철;최석모;황태원;신상운
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.110-120
    • /
    • 2005
  • ${\cdot}$저준위 고체폐기물의 유리고화처리 적용연구를 위하여, 현대모비스는 원자력환경기술원 및 프랑스 SGN사와 공동으로 99년 10월에 유리화 실증설비를 건설한 바 있다. 실증설비를 활용하여 모의핵종(Co, Cs)을 포함한 비방사성 이온교환수지, 잡고체 등에 대한 70여 회 이상의 실증시험 수행을 통하여, 대상폐기물을 안전하고 효과적으로 처리할 수 있음을 확인하였다. 그러나 처리공정 중 고온세라믹필터계통(High Temperature Filter : HTF)에서 발생하는 분진의 처리가 문제점으로 도출되었다. 또한 저온용융로(Cold Crucible Melter : CCM)와 HTF를 연결하는 냉각파이프는 장기간 운전시 CCM으로부터 발생한 분진이 침적되어 배관막힘의 우려가 있다. 이와 관련, 기 개발한 유리화공정에 추가하여 HTF에서 발생한 분진을 재순환하는 장치와 냉각파이프 내 침적분진을 제거하는 장치를 개발하였다. 유리화공정 중 HTF에서 발생하는 분진의 처리는 유리화설비의 감용비, 처분비용 및 유리용탕의 조절 측면에서 특히 중요하다. 분진재순환장치(Dust Recycling System : DRS)의 개념은, HTF 하단부에서 발생분진을 수거, 물과 섞어 슬러리 형태로 제조, 이송하여 CCM 내로 다시 투입함으로써 분진을 처리할 수 있도록 하였다. DRS의 주 기능은 분진 내의 모의핵종 및 주요 유리성분을 다시 CCM으로 재순환 처리하는 것이며, 이에 따라 유리용탕의 성분을 일정하게 유지하고 또한 유리배출을 용이하게 하는 데 기여한다. 또한 시멘트 고화설비 등과 같은 별도의 분진처리설비를 고려할 필요가 없다. 제진장치는 주기적으로 운전 중 가동할 경우, 냉각파이프 내의 분진침적에 의한 막힘 방지와 함께 배관 내 침적된 분진을 CCM 내로 다시 처리하는 효과를 기대할 수 있다. 유리화실증시험을 통하여 DRS와 제진장치에 대한 전체적인 성능평가를 성공적으로 수행하였으며, 운전결과 및 경험은 향후 상용설비를 위한 기본자료로 활용할 것이다.

  • PDF

슬러지 유중 건조에 대한 전산 해석 및 실험적 연구 (A Numerical and Experimental Study for Fry-drying of Various Sludge)

  • 신미수;김혜숙;김병갑;황민정;장동순;엄태인
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.341-348
    • /
    • 2010
  • 유중 건조 공정의 기본 원리는 수분과 비열차이가 있는 오일을 가열할 때 온도 차이에 따라 형성되는 슬러지 내부의 급격한 압력 변화를 이용한다. 즉 슬러지 내부에 발생하는 급격한 압력 상승이 이루어질 때 슬러지 공극을 통하여 수분이 빠르게 배출하도록 하는 것이다. 본 연구의 목적은 유중 건조공정 중 다양한 운전 변수가 건조효율에 미치는 영향을 구체적으로 규명하기 위한 것이다. 변수 연구를 위하여 일련의 건조 실험과 수치해석을 시도하였으며 그 결과 건조온도, 건조시간, 폐오일종류, 슬러지 종류 등 중요 실험변수에 따른 건조곡선이 얻어졌다. 건조 온도 변화에 따른 연구 결과는 폐오일의 종류에 관계없이 $140^{\circ}C$ 이상으로 운전하는 것이 건조효율에 유리한 것으로 나타났으며 이 결과는 수치 해석적 결과로도 확인되었다. 그리고 슬러지 직경의 경우 직경이 감소할수록 효율적으로 건조되는 경향으로 보였으며 이는 비표면적의 증가에 기인하는 것으로 판단되었다. 오일 종류나 물성의 변화에 대한 연구에서는 오일의 점도가 가시적인 영향을 주는 것으로 나타났다. 특히 점도가 높은 오일의 경우 건조 초반에 수분 증발이 현저히 지체되는 현상이 나타났다. 그러나 건조온도 $140^{\circ}C$ 이상에서는 이러한 지체 현상이 감소하는 결과를 나타내었다. 슬러지 종류에 따른 연구에서는 전체적으로 큰 차이를 나타내지는 않았으나 하수슬러지가 다른 종류의 슬러지에 비하여 좀 더 가시적으로 양호한 수분제거 양상을 나타내었다. 수치 해석적 연구는 실험적 연구에 대한 상호보완적인 연구로서 가능성을 보였으나 복잡한 세부모델에 대한 경험적인 모델개발의 필요성이 제기되었다.

CSOs처리를 위한 응집침전시스템에서 슬러지 반송에 의한 고형물 처리효율평가 (An Evaluation of Solid Removal Efficiency in Coagulation System for Treating Combined Sewer Overflows by Return Sludge)

  • 하성룡;이승철
    • 대한환경공학회지
    • /
    • 제35권3호
    • /
    • pp.171-178
    • /
    • 2013
  • 본 연구는 CSOs의 처리를 위해 개발된 응집침전시스템의 운전초기에 발생하는 침전슬러지를 응집반응조에 반송하였다. 슬러지 반송을 통해 생성되는 플록의 형성특성 및 침전특성을 분석하고, CSOs 유입초기의 고농도 입자성 물질이 가중응집제로 활용될 수 있는지 그 가능성을 평가하고자 하였다. 그 결과, CSOs는 유입초기 고농도의 오염물질을 포함하며, 특히 20 ${\mu}m$ 이상의 입자성 물질이 다량 유입되었다. 응집침전시스템을 통해 처리된 유출수는 고농도의 오염물질이 유입되는 시기에는 처리수질이 낮아졌으나, 이후 유입오염물질의 농도가 감소되는 시점에서는 처리수질이 증가하는 현상을 보였다. 슬러지반송 운전에서 생성되는 플록은 마이크로샌드를 주입한 플록에 비해 크기는 비슷하고, 침강속도는 55.1 cm/min에서 21.5 cm/min으로 감소하였다. 반송에 사용되는 침전조 하부에 축적된 슬러지의 SVI값은 72로 침강성이 양호하였으며, 침전된 슬러지가 압밀침전으로 인해 부피가 급격히 감소하는데 걸리는 시간은 10분 정도로 분석되었다. 반송슬러지는 인발 0.3%에 반송 0.1%의 조건에서 지속적인 슬러지 발생에 따른 침전과 인발의 균형이 형성되는 것으로 분석되었으며, 이때, 응집반응조의 평균 TS농도는 100~200 mg/L, VS농도는 50~100 mg/L 정도를 유지하도록 슬러지를 반송하는 것이 적절한 것으로 분석되었다. CSOs의 입자성물질을 함유한 슬러지의 반송은 유입수질의 변화에 대응하여 안정적인 처리수의 수질을 확보할 수 있고, 약품주입량의 감소와 함께 슬러지 발생량의 감소효과를 기대할 수 있다.

『청음록(晴陰錄)』으로 본 (사(社))유도회(儒道會) 약사(略史) (Outline History of Corporation Yudohoi(儒道會) via 『Cheongeumrok(晴陰錄)』 by Hong Chan-Yu: "Volume of Materials")

  • 정후수
    • 동양고전연구
    • /
    • 제55호
    • /
    • pp.265-291
    • /
    • 2014
  • "청음록(晴陰錄)"은 권우 홍찬유(1915-2005) 선생의 일기(1969년 1월 9일~1982년 1월 14일)이다. 선생은 사단법인 유도회의 창립부터 모든 운영에 직접관여하였으므로 유도회의 역사를 가장 잘 알고 있는 분이다. 따라서 이 "청음록"은 유도회 역사를 정리하는데 적합한 자료로서 충분한 가치가 있다고 본다. "청음록"은 모두 19권으로 구성되었으며, 총 분량은 200자 원고지 3,300매 정도이다. 일기 작성은 한문으로 되어있으며, 한문 문장으로 썼으되 한글 문장 어순을 따르기도 하였다. 그리고 원문의 많은 부분이 초서(草書)로 씌어있고, 또 중간 중간에 많은 한시(漢詩)가 삽입되어 있다. 이 원고는 일기 중에서 사단법인 유도회에 관련된 주요사항만을 발췌한 것이다. 1. 사단법인은 1968년 11월 창립 발기인대회를 열고 이듬해 1969년 1월에 문공부로부터 인가를 받아 설립되었다(문화부장관 허가번호 제다-2-3호(종무 1732.5). 2. 사무실은 처음 서울 종로구 원남도 133-1 원남빌딩 3층(현 서울대병원 앞 대학약국 자리)에서, 종로구 관수동 경보빌딩 2층, 다시 종로구 예지동 4번지 광장회사 388호실(흥산친목회(興産親睦會) 사무실)로 이전, 이후 경운동 건국빌딩 3층으로 이전하였다. 3. 운영비 조달은 성종호 이사장의 장남 성상영의 지원, 후에는 차기 이사장인 김원태, 권태훈이 담당하였으며, 1979년부터는 홍찬유 이사가 부담하였다. 3. 유림 활동으로는, 성균관 석전제(釋奠祭) 참가를 비롯하여, 파리장서비건립(巴里長書碑建立) 및 건립 기념시집 발간, 유림독립운동사 열전편찬(미완), 가정의례준칙 제정에 실천위원으로 참가하였다. 4. 성균관과의 분쟁이 있었으나, 1975년 7월 고법, 1976년 2월 대법에서 패소하였다. 5. 성균관 유도회와 통합에 관한 의논이 있기는 하였으나 거의 진척이 없었다. 6. 1979년부터 본격적인 유교 경서 및 한문 강좌를 홍찬유 이사가 주도하여 현재까지 지속되고 있다. 현재 일반 시민 강좌를 비롯하여, 장학생 강좌가 30년을 맞이하고 있으며, 수료생이 220명에 달하고 있다.

뇌졸중 환자에 적용한 핫라인 전화상담 프로그램의 효과 (Effects of Telephone Hotline Counseling Program on Stroke Care)

  • 김백균;강동완;김도연;박정현;우지석;김영희;김현숙;문민주;이정윤;국형석;김낙훈;최상원;안하규;양성규;김준엽;강지훈;한문구;배희준;김범준
    • 보건행정학회지
    • /
    • 제33권2호
    • /
    • pp.185-193
    • /
    • 2023
  • Background: This study focuses on the establishment and operation of a stroke patient hotline program to help patients and their caregivers determine when acute neurological changes require emergency attention. Method: The stroke hotline was established at the Gyeonggi Regional Cerebrovascular Center, Seoul National University Bundang Hospital, in June 2016. Patients diagnosed with stroke during admission or in outpatient clinics were registered and provided with stroke education. Consulting nurses managed hotline calls and made decisions about outpatient schedules or emergency room referrals, consulting physicians when necessary. The study analyzed consultation records from June 2016 to December 2020, assessing consultation volumes and types. Outcomes and hotline satisfaction were also evaluated. Results: Over this period, 6,851 patients were registered, with 1,173 patients (18%) undergoing 3,356 hotline consultations. The average monthly consultation volume increased from 29.2 cases in 2016 to 92.3 cases in 2020. Common consultation types included stroke symptoms (22.3%), blood pressure/glucose inquiries (12.8%), and surgery/procedure questions (12.6%). Unexpected outpatient visits decreased from 103 cases before the hotline to 81 cases after. Among the 2,244 consultations between January 2019 and December 2020, 9.6% were recommended hospital visits, with two cases requiring intra-arterial thrombectomy. Patient satisfaction ratings of 9-10 points increased from 64% in 2019 to 69% in 2020. Conclusion: The stroke hotline program effectively reduced unexpected outpatient visits and achieved high patient satisfaction. Expanding the program could enhance the management of stroke-related neurological symptoms and minimize unnecessary healthcare resource utilization.