• Title/Summary/Keyword: High Volume

Search Result 6,378, Processing Time 0.037 seconds

Volume Pulse Wave Detection System for Oriental Medicine (한방용 용적맥파 시스템)

  • Kim, H.T.;Han, S.C.;Choi, T.J.;Kim, J.K.;Huh, W.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, we devised volume pulse detection system which can quantitatively represent a artery elasticity for oriental clinic. Volume pulse wave detecter system consist of transducer which has IRLED-photodiode detecter, temperature sensor and filter and preprocessing circuits, data conversion and serial communication parts, and computer system. The high-pass filter are detect volume pulse wave and lowpass filter detect tissue thickness. The detected volume pulse wave are normalized by tissue thickness value with a division process. As the result of experiment, we can detect normalized volume pulse wave with effectively.

  • PDF

Development of Volume Monitoring System Filled in Storage Space (저장공간에 채워진 부피 모니터링 시스템 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.129-133
    • /
    • 2019
  • In this paper, we developed a system to monitor the storage capacity of suction-type device such as vacuum cleaner or crop harvesters. The monitoring system consists of load cells and a differential pressure sensor which simultaneously monitor the weight and volume of the stock. Since weighing objects stored in storage containers alone cannot fully monitor the level of filling, more accurate monitoring can be achieved by monitoring volume and fusion with weight information. The volume was monitored using a phenomenon in which the flow rate of the inhaled air varies depending on the volume of the object filled in the storage container. In this paper, we developed a system to monitor the storage in three stages: low, medium and high.

Does Hospital Volume Really Affect the Surgical and Oncological Outcomes of Gastric Cancer in Korea?

  • Kim, Eun Young;Song, Kyo Young;Lee, Junhyun
    • Journal of Gastric Cancer
    • /
    • v.17 no.3
    • /
    • pp.246-254
    • /
    • 2017
  • Purpose: The significance of hospital volume remains inconsistent and controversial. In particular, few studies have examined whether hospital volume is associated with the outcome of gastrectomy for gastric cancer in East Asia. This study examined the effect of hospital volume on the short-term surgical and long-term oncological outcomes of patients undergoing curative gastrectomy for gastric cancer. Materials and Methods: Between 2009 and 2011, 1,561 patients underwent curative gastrectomy for gastric cancer at Seoul St. Mary's Hospital (n=1,322) and Bucheon St. Mary's Hospital (n=239). We defined Seoul St. Mary's Hospital as a high-volume center and Bucheon St. Mary's Hospital as a low-volume center. Results: The extent of resection, rate of combined resection, tumor stage, operating time, and hospital stay did not differ significantly between the 2 hospitals. In addition, the hospital volume was not significantly associated with the 30-day morbidity and mortality. When the overall and disease-free survival rates of the patients were stratified according to stage, hospital volume was not significantly associated with prognosis at any stage. Conclusions: Hospital volume might not be a decisive factor with respect to the surgical and oncological outcomes of patients if well-trained surgeons perform gastrectomy for gastric cancer.

A Preliminary Mortar Test to Minimize the Paste Volume of Concrete (콘크리트의 페이스트 체적을 최소화하기 위한 예비 모르타르 시험)

  • Choi, Jae-Jin;Choi, Doo-Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.741-744
    • /
    • 2008
  • There are two ways to reduce cement content for a given quality level(strength, workability etc.) in concrete. First, reducing the required paste volume by varying the shape or the grading of aggregates. Secondly, holding the paste volume constant while replacing cement volume with mineral admixtures or mineral fillers. And It will also be proved that the required minimum paste volume is independent of the paste composition, provided the paste composition is in a reasonable range. In this study, therefore, we have an object to determine the required minimum paste volume for a given workability level. For this purpose, we tried the following experiments: vary the paste volume for the three different grading of aggregates and determine the minimum paste volume to achieve a certain level of workability with high-range water reducing admixture.

  • PDF

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

The Estimation of Soil Conversion Factor using Digital Imagery (수치영상을 이용한 토량환산계수 산정)

  • 이종출;차성렬;장호식;김진수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.169-174
    • /
    • 2003
  • Design of a rational earth volume conversion coefficient is required as the earth volume conversion coefficient may give great influence on construction work volume and construction costs in the civil engineering works where large-scaled earth volume is excavated. However, there are a great deal of difficulties in the calculation of the exact spoil surface earth and Insufficient earth volume by adopting the figures presented on the generally used design specifications which are not the results obtained from the selection tests in calculating the earth volume conversion coefficient. In this connection, it would be desirable to calculate the earth volume conversion coefficient by carrying out large-scaled site test adequate for the relevant environment. In consequence, this study aims at calculating the exact earth volume conversion coefficient of cutting and banking areas of weathering rocks in large-scaled construction sites where land is being developed into home lots. For this, we have excavated the respective 20 sites of the cutting and banking areas in the said site and then calculated the volume after the excavation. As a result, the relative exactness degree of the crossing was calculated at 0.5% in average. The relative exactness degree of 0.5% in the volume may be judged as an exact measurement as it corresponds to 0.17% of the relative exactness degree in the length measurement. We have calculated the exact earth volume conversion coefficient by the use of function ratio as per the wet unit weight and the indoor soil quality test as per volume calculated. And then we have found out minor differences as a result of the comparison and analysis with the earth volume conversion coefficient determined by the dry unit weight test as per sand replacement method. This may be judged as a rational design method for the calculation of earth volume conversion coefficient, as well as high reliability of site test as a precision photogrammetry is adopted for volume measurement of the irregular excavating areas.

  • PDF

A Basic Study on Noodle Making and Cooking with Cheong-song Mineral Water (청송약수를 이용한 면 제조 및 조리에 관한 기초연구)

  • Lee, Sung-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.4
    • /
    • pp.820-826
    • /
    • 2012
  • This is a basic study of Cheong-song mineral water, which has high contents of Ca and Mg for making noodles as well as for general cooking. The test results of the noodles manufactured and cooked with mineral water were compared to those manufactured and cooked with distilled water and tap water. Noodles manufactured with mineral water showed higher values than others in the cooked weight, volume, water absorption ability, turbidity, lightness (L) and redness (a) on the minus scale. This means that we can manufacture cooked noodles that have high weight, high volume, high water absorption ability and high lightness (L) along with a slight green color with Cheong-song mineral water. Cooked noodles manufactured with mineral water showed significant differences in the cooked weight and volume compared to those manufactured with distilled water. Also, cooked noodles manufactured with mineral water showed significant differences in moisture absorption, turbidity, lightness (L), redness (a) and yellowness (b) compared to those manufactured with distilled water and tap water. Commercial noodles cooked in mineral water showed significant differences in the cooked weight and redness (a) compared to those cooked in distilled water and tap water. Further, commercial noodles cooked in mineral water showed significant differences in weight, volume and brightness (L) compared to those cooked in distilled water.

Experiment of Flexural Behavior of Reinforced Concrete Beams with High Volume Fly Ash (하이 볼륨 플라이애쉬 철근콘크리트 보의 휨거동 실험)

  • Yoo, Sung-Won;Lee, Hyung-Jib
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.323-329
    • /
    • 2014
  • It is known that the best way to recycle fly ash is to use in concrete. It is impossible to bury in the ground this fly ash recently, so it is trying to use high volume fly ash concrete. Nevertheless, recent main research topics are focused in the part of material only, however, it is necessary to perform the researches about elasticity modulus, stress-strain relationship and structural behavior. Therefore, in this paper, 18 test members were manufactured with 3 test variables, namely fly ash replacement ratio 0, 35, 50%, concrete compressive strength 20, 40, 60 MPa and 2 tensile steel ratio. 18 test members were tested for flexural behavior. From the test results, there were no differences between 35, 50% high volume fly ash cement concrete and ordinary concrete without fly ash(FA=0%).

An Empirical Analysis about the Effect on Performance of Firm's Patent Competency : Focusing on the High Performance Venture Firms in Korea (기업의 특허 역량이 성과에 미치는 영향에 관한 실증 분석 : 우수 벤처기업을 중심으로)

  • Ahn, Yeon S.
    • Knowledge Management Research
    • /
    • v.11 no.1
    • /
    • pp.83-96
    • /
    • 2010
  • In this study, the effect of firm's patent competency on the their management performance was analysed. The number of patents granted to Korean firms, patent grade score as of the firm's patent competence were considered in the perspectives of patent volume and patent value respectively. Specially the analysis were implemented focusing on the high performance venture ranked 200th in Korea. The patent source data were from the Korean Intellectual Property Office, Korean Credit Evaluation Information Company, and the Patent Evaluation System of KIPO and KIPA. And the year sales and net profit volume as of the firm's management performance data from the KIS. Management performance data are consisted of the mean sales, net profit and ROI during the 4 years from FY2005 to FY2008. Major results are as follows. The regression model were proved significantly that the year sales volume and net profit are effected by the number of patents and patent grade score. But the model including the ROI were shown not significantly. So it can be concluded that patent volume and patent value are the important factors on firm's financial performance as of the year sales volume and net profit. Also the regression model including the control variables, firm's number of employee and business year, the number of patents and patent grade score are the significant factors on firms performance. And regression coefficients of patent value model were higher than these of patent volume model. So it can be recognized that patent value of firms' patent competency are more important factor than the patent volume.

  • PDF

Development of a High Energy Ignition System Using Corona Discharge (코로나 방전을 이용한 고에너지 점화 시스템 개발)

  • Park, Kyongseok;Choi, Duwon;Kang, Hyehyun;Lee, Jonghwa;Park, Jinil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.6
    • /
    • pp.650-655
    • /
    • 2015
  • A high energy ignition system is essential for lean burn or high EGR gasoline engine, which is getting more and more interest to improve fuel economy. The high energy ignition systems comprise plasma jet, laser beam, corona discharge and so on. In this study, a high energy ignition system using corona discharge is developed and tested in a constant volume combustion chamber. The developed system shows extension of lean limit of propane-air mixture and enhencement of combustion speed. Various shape of corona discharge plugs are also tested and compared in this study.