• Title/Summary/Keyword: High Voltage DC Transmission

Search Result 95, Processing Time 0.027 seconds

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Circuit-Level Reliability Simulation and Its Applications (회로 레벨의 신뢰성 시뮬레이션 및 그 응용)

  • 천병식;최창훈;김경호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.1
    • /
    • pp.93-102
    • /
    • 1994
  • This paper, presents SECRET(SEC REliability Tool), which predicts reliability problems related to the hot-carrier and electromigration effects on the submicron MOSFETs and interconnections. To simulate DC and AC lifetime for hot-carrier damaged devices, we have developed an accurate substrate current model with the geometric sensitivity, which has been verified over the wide ranges of transistor geometries. A guideline can be provided to design hot-carrier resistant circuits by the analysis of HOREL(HOT-carrier RFsistant Logic) effect, and circuit degradation with respect to physical parameter degradation such as the threshold voltage and the mobility can also be expected. In SECRET, DC and AC MTTF values of metal lines are calculated based on lossy transmission line analysis, and parasitic resistances, inductances and capacitances of metal lines are accurately considered when they operate in the condition of high speed. Also, circuit-level reliability simulation can be applied to the determination of metal line width and-that of optimal capacitor size in substrate bias generation circuit. Experimental results obtained from the several real circuits show that SECERT is very useful to estimate and analyze reliability problems.

  • PDF

Linearity Optimization of DC CT and a Study on the Application of HVDC System (HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구)

  • Choi, Yong-Kil;Lee, Eun-Jae;Choi, Ho-Seok;Lee, Wook-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

Smart Far-Field Wireless Power Transfer via Time Reversal (시간 역전을 기반으로 한 지능적 원거리 무선전력전송)

  • Park, Hong Soo;Hong, Ha Young;Hong, Sun K.
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.285-289
    • /
    • 2018
  • In this paper, we demonstrate electromagnetic wave focusing and rectification based on time reversal as a smart method for far-field wireless power transfer. Time reversal in a complex propagation environment allows for transmission of high peak power pulses by focusing the electromagnetic waves selectively regardless of the receiver position. We demonstrate wave focusing and radio frequency (RF) to direct current (DC) rectification via numerical simulation of a complex propagation environment. The results reveal that time reversal can ensure peak power up to 12 dB greater compared to a narrowband continuous wave signal, thereby enhancing the rectified DC voltage with better efficiency.

Turn-to-Turn Dielectric Characteristics of Coils for HTSFCL (고온초전도 한류기용 코일의 턴간 절연 특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Nguyen, Van Dung;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.15-18
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

  • PDF

Tracking/Erosion Resistance Analysis of Nano-Al(OH)3 Filled Silicone Rubber Insulating Materials for High Voltage DC Applications

  • Kannan, P.;Sivakumar, M.;Mekala, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.355-363
    • /
    • 2015
  • HVDC technology has become popular as an economic mode of bulk power transmission over very long distances. Polymeric insulators in HVDC power transmission lines are affected by surface tracking and erosion problems due to contamination deposit, which pose a greater challenge in maintaining the reliability of the HVDC system. In addition, polymeric insulators are also naturally affected by aging due to various environmental stresses, which in turn accelerates the surface tracking and erosion problems. Research works towards the improvement of tracking and erosion resistance of polymeric insulators by adding nano-sized fillers in the base material are being carried out worldwide. However, surface tracking and erosion performance of nano-filled aged polymeric insulators for HVDC applications are not well reported. Hence, in the present work, tracking and erosion resistance of the nano $Al(OH)_3$ filled silicone rubber insulation material has been evaluated under DC voltages at different filler concentrations and aged conditions, as per IEC 60587 test procedures. Leakage current and contact angle measurements were carried out to understand the surface hydrophobicity. Moving average technique was used to analyze the trend followed by leakage current. Water aged specimen shows less tracking resistance when compared with thermal aged specimen. It is observed that nano-filler concentration of 5% is even sufficient to get better tracking/erosion resistance under DC voltages.

Effect of Thermal Aging on Electrical Properties of Low Density Polyethylene

  • Wang, Can;Xie, Yaoheng;Pan, Hua;Wang, Youyuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2412-2420
    • /
    • 2018
  • The thermal degradation of low density polyethylene (LDPE) will accelerate the production of carbonyl groups (C=O), which can act as the induced dipoles under high voltage. In this paper, we researched the dielectric properties and space charge behavior of LDPE after thermal aging, which can help us to understand the correlation between carbonyl groups (C=O) and electrical properties of LDPE. The spectra results show that LDPE exhibit obvious thermooxidative reactions when the aging time is 35 days and the productions mainly contain carboxylic acid, carboxylic eater and carboxylic anhydride, whose amount increase with the increasing of aging time. The dielectric properties show that the real permittivity of LDPE is inversely proportional to temperature before aging and subsequently become proportional to temperature after thermal aging. Furthermore, both the real and imaginary permittivity increase sharply with the increasing of aging time. The fitting results of imaginary permittivity show that DC conductivity become more sensitive about temperature after thermal aging. On this basis, the active energies of materials calculated from DC conductivity increase first and then decrease with the increasing of aging time. In addition, the space charge results show that the heterocharges accumulated near electrodes in LDPE change to the homocharges after thermal aging and the mean volume charge density increase with the increasing of aging time. It is considered that the overlaps caused by electrical potential area is the main reason for the increase of DC conductivity.

Development of Optical Video Device for HD-SDI Video Signal Transmission (HD-SDI 비디오 신호 전송을 위한 광 비디오 전송 장치 개발)

  • Lee, Dong-Real
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.245-250
    • /
    • 2015
  • We have developed an optical video transmission device for HD-SDI signal transmission. The optical transmitter/receiver unit operates at DC 5 volt and small enough to be attaced near surveillance camera. They have internal voltage regulating circuits to supply 3.3V to other circuits inside the unit. The optical transmitter is composed of cable driver, laser diode driver, and laser diode. The optical receiver is composed of photodiode, limiting amp, and cable equalizer. The wavelength of the trasmitter was 1.3 um, and optical power was -5dBm, and the speed was 1.485Gbps. The receiver sensitivity was -23 dBm. We confirmed that the optical device can transmit HD-SDI video through 30 km optical fiber without any interruption.

Design and Implementation of a Universal System Control Strategy Applicable to VSC-HVDC Systems

  • Zhao, Yue;Shi, Li-bao;Ni, Yi-xin;Xu, Zheng;Yao, Liang-zhong
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.225-233
    • /
    • 2018
  • This paper proposes a universal system control strategy for voltage source converter (VSC) based high voltage direct current (HVDC) systems. The framework of the designed control strategy consists of five layer structures considering the topology and control characteristics of the VSC-HVDC system. The control commands sent from the topmost layer can be transmitted to the next layer based on the existing communication system. When the commands are sent to each substation, the following transmission of commands between the four lower layers are realized using the internal communication system while ignoring the communication delay. This hierarchical control strategy can be easily applied to any VSC-HVDC system with any topology. Furthermore, an integrated controller for each converter is designed and implemented considering all of the possible operating states. The modular-designed integrated controller makes it quite easy to extend its operating states if necessary, and it is available for any kind of VSC. A detailed model of a VSC-HVDC system containing a DC hub is built in the PSCAD/EMTDC environment. Simulation results based on three operating conditions (the start-up process, the voltage margin control method and the master-slave control method) demonstrate the flexibility and validity of the proposed control strategy.

A Fault Location Algorithm for a Transmission Line Using Travelling Waves (진행파를 이용한 송전선로의 고장점 표정 알고리즘)

  • Kang Sang-Hee;Kim Jin-Han
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.10
    • /
    • pp.542-549
    • /
    • 2004
  • The conventional fault location algorithms based on the travelling waves have an inherent problem. In cases of the close-up faults occurring near the relaying point and of the faults having zero degree inception angle of voltage signals, the conventional algorithms can not estimate an accurate fault distance. It is because the shapes of travelling waves are near sinusoidal in those cases. A new method solving this problem is presented in this paper. An FIR(Finite Impulse response) filter which makes high frequency components prominent and makes the power frequency component and dc-offset attenuated is used. With this method, the cross-correlation peak is to be very clear when a close-up fault or a fault having near zero-degree inception angle occurs. The cross-correlation peaks can be clearly distinguished and accurate fault location is practically possible consequently. A series of simulation studies using EMTP(Electromagnetic Transients Program) show that the proposed algorithm can calculate an accurate fault distance having maximum 2% or less error.