• Title/Summary/Keyword: High Vibration

Search Result 4,260, Processing Time 0.032 seconds

Development of Speed Increaser for High Speed Machine Pump which Considered the Noise/Vibration (소음/진동을 고려한 고속머신 펌프용 증속기 개발)

  • 이동환;박노길;김병옥;이형우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.363-369
    • /
    • 2004
  • Vibration/noise analysis as well as strength of gear teeth, roller bearing life. joural bearing design are considered in order to develop the high-speed machine centrifugal pump which had a speed increaser. A Campbell diagram, in which the excitation sources caused by the mass unbalance of the rotors and the transmitted errors of the gearing are considered. shows that. at the operating speed. there are not the critical speed. A high-speed machine centrifugal pump was made in order to evaluate developed speed increaser. Also, strict API standard were introduced for reliability evaluation of developed speed increaser, and performance evaluation were carried out. The result that evaluation items about bearing vibration, shaft vibration, noise, and lubrication temperature were selected, and were tested. a high-speed machine centrifugal pump were able to know what were satisfied with API standard all.

Noise and Vibration Reduction of High-speed Cutter (고속절단기의 진동.소음 저감 연구)

  • 기호철;박주표;차원준;최연선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.944-949
    • /
    • 2003
  • A High-speed cutter, a kind of electric tool is studied to reduce its vibration and noise. The experimental modal analysis, the operational deflection shapes(ODS) and the time domain analysis(TDA) are used in the SMS software to analyze the vibration signals from an operating high-speed cutters under steady state operating condition. The second mode and fifth m,)do of the base plate coincide with the driving frequencies of the motor, And the vibration of the wheel cover is caused by the gap between the main wheel cover and the sub wheel cover. The structural modification for the base plate was done to reduce the vibration. The effect of modification is verified through the test.

  • PDF

Measurement of Vibration Signals of a Gun Barrel Type Structure using Mechanical Filter (기계적 필터를 이용한 포신형상 구조물의 진동신호 측정)

  • Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.440-443
    • /
    • 2010
  • This paper deals with the method of vibration measurement of a gun barrel structure using mechanical filter. When a bullet with high speed is moving within a gun barrel type structure with low bending vibration frequencies, it is difficult to measure the bending vibration signals of the structure. For example, noncontact type sensors such as displacement or velocity sensor are not appropriate for the measurement of vibrational signals because of the movement effect of the equipment frame through the moving structures or effect of the ground vibration. One of contact type sensors such as accelerometer is profitable for measurement of vibrational signals because of its wide measurement ranges. In the case of a gun barrel structure including high vibrational signals like shock waves, however, it is necessary to propose vibration measurement method filtering high frequencies. The purpose of the paper is to propose the proper vibrational measurement technique filtering high frequencies of a gun barrel type structure.

HIGH-FREQUENCY AND COMPLEX VIBRATION ULTRASONIC WIRE BONDING SYSTEMS

  • Jiromaru Tsujino;Tetsugi Ueoka;Takahiro Mori;Koichi Hasegawa;Daisuke Kadota
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.824-829
    • /
    • 1994
  • High-frequency and complex vibration ultrasonic wire bonding systems are propsed and their welding characteristic are studied. Ultrasonic wire bonding is used widely for joining thin connecting wire of various electronic devices including IC or LSI. Conventional bonding systems use vibration frequency of 40 or 60 kHz and linear vibration welding tips. Complex vibration welding tip which vibrates in elliptical to circular or rectangular to square in the same or different frequency is effective to join welding specimens in shorter welding time and under smaller vibration amplitude, and furthermore high-frequency systems such as 90, 120, 190 kHz are also significantly effective. High-frequency and complex vibration welding system of 90, 120 and 190 kHz are designed. Welding characteristics of these systems are found very superior than a conventional system. Welding specimens of aluminum wire of 0.1mm diameter are successfully.

  • PDF

Two-time Scale Controller Design for Vibration Reduction of High Speed Cartesian Manipulator (고속 직교 머니풀레이터의 진동 감소를 위한 Two-time scale 제어기 설계)

  • 강봉수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.107-114
    • /
    • 2004
  • This paper presents a two-time scale approach for vibration reduction of a high speed Cartesian manipulator. High speed manipulators would be subject to mechanical vibration due to high inertia forces acting on linkages. To achieve high throughput capability, such motion induced vibration would have to be damped quickly, to reduce settling time of the manipulator end-effector. This paper develops a two-time scale model fer a structurally-flexible Cartesian manipulator. Based on the two-time scale model, a composite controller consisting of a computed torque method for the slow time-scale rigid body subsystem, and a linear quadratic state-feedback regulator for the fast time-scale flexible subsystem, is designed. Simulation results show that the proposed two time-scale controller yields good performance in attenuating structural vibration arising due to excitation from inertial forces.

Vibration Reduction of Pump And Pipe System (배관계와 조합된 대형 수직펌프의 유체진동 저감)

  • 배춘희;김성휘;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.263-266
    • /
    • 2004
  • In this paper, Firstly, it is shown that the high vibration source of piping and pump system is the Resonanse of pump and piping system. Secondly, in order to decrese the high vibration of pump and piping system, some practical Friction damper with high damping have been developed and its effectiveness is investigated as installing it at piping system practically.

  • PDF

High Vibration Phenomena due to Cylinder Explosion Pressure of Low-speed Diesel Engine with 7 Cylinders installed on Land (육상에 설치된 저속 7실린더 디젤엔진의 폭발 기진력 및 고진동 현상)

  • Kim, Yeon-Wahn;Bae, Yong-Chae;Bae, Chun-Hee;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.826-834
    • /
    • 2007
  • A 7K60MC-S low speed diesel engine in a power plant has frequently experienced high vibration since the unit completed construction works. Up to date, no fundamental vibration solutions were reached. Hence, several vibration tests and analyses were conducted to identify the root cause of this high vibration and to suggest the optimal countermeasures for diesel engine. The 9.25 Hz and 25.4 Hz vibrations have been observed on main body during operation. The magnitude of engine upper structural vibration is generally similar in horizontal transverse direction. However, differences in the 'Fore' and 'After' vibration magnitude with the same vibration phase angle at 9.25 Hz occur due to the explosion pulsations of 7 cylinders and the Inertia momentum added by the SCR (selective catalytic reduction) duct system. It was analyzed that the excess structural vibration occurred when the natural frequency of engine body is affected by the exciting sources due to the explosion pressure and the discharge pulsation of the seven cylinders in resonance range.

The Diagnosis of Cooling Tower System (Cooling Tower System 진동 진단)

  • Lee, Sun-Hwi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1090-1094
    • /
    • 2007
  • The aim of this study is to estimate the cause of Cooling Tower vibration and eliminate the faults of fan with high vibration in spite of overhaul. The cause of high vibration was that the natural frequency of fan blade coincide with second blade pass frequency. To achieve reduction of Cooling Tower vibration, change motor speed from 1784rpm to 1714rpm, and then the vibration has reduced conspicuously.

  • PDF

Dynamic Characteristics of the Vibration Isolation System for High Precision Processing Machinery (정밀가공장비용 면진시스템의 동특성)

  • 김영중;김병현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1115-1121
    • /
    • 2003
  • The vibration isolation table system for the high precision Processing machinery has been developed. The system uses air spring as its isolation elements. An investigation of the model and the test results showed that the diaphragm has a role in the mathematical model. The vibration levels at various floors in the laboratory were investigated during operating the large shaking table for the selection of optimum installation location. The vibration test on the designed system showed good isolation performances.

  • PDF

A study on the Vibration Reduction of the Commercial High-speed Train (운영 중인 고속열차의 진동저감에 관한 연구)

  • Jeon, Chang-Sung;Choi, Sunghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.697-704
    • /
    • 2017
  • This study was carried out to investigate and alleviate the vibration problem of commercial high-speed trains. First, the measurement of the carbody vibration was performed, in order to determine the vibration level of the high-speed train. The measurement result showed that the vibration level of the driver cab was higher than that of the passenger car and that the vibration became bigger toward the trailing end of the train. The vertical vibration of the driver cab and passenger car was larger than the transverse vibration, and the maximum value of the vibration in the ballast section was larger than that in the concrete section. A dynamic analysis was carried out to improve the vibration of the KTX-Sancheon train. The results of the analysis showed that it is necessary to reduce the vibration of the driver cab and both ends of the passenger cars. To reduce the vibration of the driver cab, it was recommended that the stiffness of the secondary coil spring be reduced and the damping coefficient of the secondary vertical damper be increased. It was found that the failure of the suspension system could be the origin of the vibration problem of the high-speed train. The proper management of wheel wear plays an important role in the improvement of the operation efficiency and reduction of the carbody vibration of high-speed trains, and research is underway to change the present wheel profile to increase the mileage between wheel turning.