• 제목/요약/키워드: High Thermal Environment

검색결과 944건 처리시간 0.034초

Evaluation of Heat Transfer Characteristics of PV Module with Different Backsheet (백시트 종류에 따른 태양전지 모듈의 방열 특성 평가)

  • Bae, Soohyun;Oh, Wonwook;Kang, Yoonmook;Lee, Hae-Seok;Kim, Donghwan
    • Current Photovoltaic Research
    • /
    • 제6권2호
    • /
    • pp.39-42
    • /
    • 2018
  • When the PV module is illuminated in a high temperature region, solar cells are also exposed to the high temperature external environment. The operating temperature of the solar cell inside the module is increased, which causes the power drops. Various efforts have been made to reduce the operating temperature and compensate the power of solar cells according to the outdoor temperature such as installing of a cooling system. Researches have been also reported to lower the operating temperature of solar cells by improving the heat dissipation properties of the backsheet. In this study, we conducted a test to measure the internal temperature of each module components and the external temperature when the light was irradiated according to the surrounding temperature. Backsheets with different thermal conductivities were compared in the test. Finally, in order to explain the temperature difference between the solar cell and the outside of the module, we proposed an evaluation method of the heat transfer characteristics of photovoltaic modules with different backsheet.

Micro to Nano-scale Electrohydrodynamic Nano-Inkjet Printing for Printed Electronics: Fundamentals and Solar Cell Applications

  • Byeon, Do-Yeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.3.2-3.2
    • /
    • 2011
  • In recent years, inkjet printing technology has received significant attention as a micro/nanofabrication technique for flexible printing of electronic circuits and solar cells, as well for biomaterial patterning. It eliminates the need for physical masks, causes fewer environment problems, lowers fabrication costs, and offers good layer-to-layer registration. To fulfill the requirements for use in the above applications, however, the inkjet system must meet certain criteria such as high frequency jetting, uniform droplet size, high density nozzle array, etc. Existing inkjet devices are either based on thermal bubbles or piezoelectric pumping; they have several drawbacks for flexible printing. For instance, thermal bubble jetting has limitations in terms of size and density of the nozzle array as well as the ejection frequency. Piezoelectric based devices suffer from poor pumping energy in addition to inadequate ejection frequency. Recently, an electrohydrodynamic (EHD) printing technique has been suggested and proposed as an alternative to thermal bubble or piezoelectric devices. In EHD jetting, a liquid (ink) is pumped through a nozzle and a strong electric field is applied between the nozzle and an extractor plate, which induce charges at the surfaces of the liquid meniscus. This electric field creates an electric stress that stretches the meniscus in the direction of the electric field. Once the electric field force is larger than the surface tension force, a liquid droplet is formed. An EHD inkjet head can produce droplets smaller than the size of the nozzle that produce them. Furthermore, the EHD nano-inkjet can eject high viscosity liquid through the nozzle forming tiny structures. These unique features distinguish EHD printing from conventional methods for sub-micron resolution printing. In this presentation, I will introduce the recent research results regarding the EHD nano-inkjet and the printing system, which has been applied to solar cell or thin film transistor applications.

  • PDF

Dry Friction Characteristics of Bulk Amorphous Thermal Spray Coating and Amorphous Metallic Matrix Composites (벌크 비정질 용사코팅과 비정질 기지 복합재료의 건조 마찰특성)

  • Jang, Beomtaek;Yi, Seonghoon
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.108-115
    • /
    • 2014
  • The friction behaviors of bulk amorphous thermal spray coating (BAC) and second phase-reinforced composite coatings using a high velocity oxy-fuel spraying process were investigated using a ball-on-disk test rig that slides against a ceramic ball in an atmospheric environment. The surface temperatures were measured using an infrared thermometer installed 50 mm from the contact surface. The crystallinities of the coating layers were determined using X-ray diffraction. The morphologies of the coating layers and worn surfaces were observed using a scanning electron microscope and energy-dispersive spectroscopy. The results show that the friction behavior of the monolithic amorphous coating was sensitive to the testing conditions. Under lower than normal loads, a low and stable friction coefficient of about 0.1 was observed, whereas under a higher relative load, a high and unstable friction coefficient of greater than 0.3 was obtained with an instant temperature increase. For the composite coatings, a sudden increase in friction coefficient did not occur, i.e., the transition region did not exist and during the friction test, a gradual increase occurred only after a significant delay. The BAC morphology observations indicate that viscous plastic flow was generated with low loads, but severe surface damage (i.e., tearing) occurred at high loads. For composite coatings, a relatively smooth surface was observed on the worn surface for all applied loads.

Conceptual design and analysis of rotor for a 1-kW-Class HTS rotating machine

  • Kim, J.H.;Hyeon, C.J.;Quach, H.L.;Chae, Y.S.;Moon, J.H.;Boo, C.J.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제19권4호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents a conceptual design and analysis for a 1-kW-class high-temperature superconducting rotating machine (HTSRM) rotor. The designed prototype is a small-scale integration system of a HTSRM and a HTS contactless rotary excitation device (CRED). Technically, CRED and HTSRM are connected in the same shaft, and it effectively charges the HTS coils of the rotor field winding by pumping fluxes via a non-contact method. HTS coils in rotor pole body and toroidal HTS wire in CRED rotor are cooled and operated by liquid nitrogen in cryogen tank located in inner-most of rotor. Therefore, it is crucial to securely maintain the thermal stability of cryogenic environment inside rotor. Especially, we critically consider not only on mechanical characteristics of the rotor but also on cryogenic thermal characteristics. In this paper, we conduct two main tasks covering optimizing a conceptual design and performing operational characteristics. First, rotor parameters are conceptually designed by analytical design codes. These parameters consider to mechanical and thermal performances such as mechanical strength, mechanical rigidity, and thermal heat losses of the rotor. Second, mechanical and thermal characteristics of rotor for 1-kW-class HTSRM are analyzed to verify the feasible operation conditions. Hence, three-dimensional finite element analysis (3D-FEA) method is used to perform these analyses in ANSYS-Workbench platform.

The Study on Structural Strength Test Technique for Cylindrical Supersonic Vehicle Subjected to Severe Heating Environment (원통형 초음속 비행체 내열구조시험 기법 연구)

  • Lee, Kyung-Yong;Kim, Jong-Hwan;Lee, Kee-Bhum;Jung, Jae-Kwon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제33권6호
    • /
    • pp.83-91
    • /
    • 2005
  • This paper describes the structural strength test technique and the results for cylindrical supersonic vehicle subjected to both aerodynamic load and thermal load. The special positioning system using spring links was designed to float, support and restrain the test airframe during the test and the down-time. The hydraulic system and the electric heating system were utilized to apply the aerodynamic load and the thermal load to the test airframe together. Particularly, several hundreds of infrared quartz lamps were used for the heating system, and the thermal test conditions were successfully simulated. The test results showed that this kind of high temperature test is adequate to verify the structure integrity and produce useful engineering data which is necessary for the possible structural modification under thermal environments.

Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations (파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가)

  • Lee, Seokjae;Oh, Kwanggeun;Han, Shin-in;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

Numerical Study on the Air Cooling Effect due to Increased Albedo in Urban Area (알베도 증가에 따른 도시 기온 하강 효과에 관한 수치연구)

  • Lee, Hyun-Ju;Lee, Kwi-Ok;Lee, Soon-Hwan;Lee, Hwa-Woon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권4호
    • /
    • pp.383-392
    • /
    • 2008
  • In order to clarify the influence of the change of urban surface albedo on mesoscale meteorological factors during the summertime, numerical experiments with various albedo of urban surface were carried out. Numerical model used in this study is PSU/NCAR MM5 V3.6. As a result of the numerical simulation intended of Busan assumed the increase of albedo of roofs, buildings, or roads, the increase of albedo can make decrease radiation effect of surface, so that it caused drops in ambient air temperature from $0.5^{\circ}C$ to $1^{\circ}C$ on the average, and the downtown of Busan formed along the trough presented a substantial drop in ambient air temperature about $1.5^{\circ}C$. Modeling studies suggest the increased surface albedo in urban area can reduce surface and air temperatures near the ground and affect related meteorological parameters such as winds and the depth of the mixed boundary layer.

A Basic Study of Thermal-Fluid Flow Analysis Using Grid Computing (그리드 컴퓨팅을 이용한 열유동 해석 기법에 관한 기초 연구)

  • Hong, Seung-Do;Ha, Yeong-Man;Cho, Kum-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제28권5호
    • /
    • pp.604-611
    • /
    • 2004
  • Simulation of three-dimensional turbulent flow with LES and DNS lakes much time and expense with currently available computing resources and requires big computing resources especially for high Reynolds number. The emerging alternative to provide the required computing power and working environment is the Grid computing technology. We developed the CFD code which carries out the parallel computing under the Grid environment. We constructed the Grid environment by connecting different PC-cluster systems located at two different institutes of Pusan National University in Busan and KISTI in Daejeon. The specification of PC-cluster located at two different institutes is not uniform. We run our parallelized computer code under the Grid environment and compared its performance with that obtained using the homogeneous computing environment. When we run our code under the Grid environment, the communication time between different computer nodes takes much larger time than the real computation time. Thus the Grid computing requires the highly fast network speed.

Effect of Body Fat on Thermophysiological Responses at a Hot Environment (체지방률이 서열환경하의 온열생리에반응에 미치는 효과)

  • Kim, Hee-Eun;Kim, Seong-Suk
    • Fashion & Textile Research Journal
    • /
    • 제6권4호
    • /
    • pp.515-521
    • /
    • 2004
  • The Purpose of this study was to investigate the effect of body fat on thermophysiological responses and subjective sensations under hot environment. Fifteen female college students volunteered as subjects. Subjects were organized into three groups - low body fat group(L group : less than 20% of body fat), medium body fat group(M group : 20%~30% of body fat) and high body fat group(H group : More than 30% of Body fat). The experiment was carried out in a climate chamber of $32^{\circ}C$, 60%RH with the repeat of having 'Exercise' and 'Rest' period. The results of this study are as follows ; Rectal temperature maintained higher in M group and L group than in H group in the period of exercise 1. High body fat was so effective in keeping the core temperature, it seems that as was usually the case in cold environment. The mean skin temperature was the lowest value in H group but the ratio of mean skin temperature change was clearly high value in H group. The above facts indicated that thermophysiological response occurs rapidly in H group. Blood pressure, pulse rate and metabolic rate of H group showed the highest values and those of L group showed the lowest value in all period of experiment. Effective of sweating rate was higher in H group than other groups. In subjective sensations, The H group felt more pleasant and comfortable than M group. With these results in mind, people of H group responses more actively for thermal regulation in a hot environment, and these leads H group to feel more pleasant and comfortable.

Effect of glass powder on the behaviour of high performance concrete at elevated temperatures

  • Kadik, Abdenour;Cherrak, Messaouda;Bali, Abderrahim;Boutchicha, Djilali;Hannawi, Kinda
    • Advances in concrete construction
    • /
    • 제10권5호
    • /
    • pp.443-454
    • /
    • 2020
  • In recent years, many studies have been done on the performance of concrete containing glass powder (GP). For the purpose of widespread use of GP in concrete mixes, a knowledge of the performance of such a mixture after a fire is essential for the perspective of structural use. This research work was carried out to evaluate the performance of High Performance Concrete (HPC) made with GP after being exposed to elevated temperature. The studied mixtures include partial replacement of cement by GP with up to 30%. The mechanical performance and structural alterations were assessed after high temperature treatment from 200℃ to 800℃. The mechanical performance was evaluated by testing the specimens to the compressive and tensile strength. In addition, the mass loss and the porosity were measured to notice the structural alterations. Changes in microstructure due to temperature was also investigated by the X-ray diffraction (XRD) and thermal gravimetric analyses (TGA) as well as porosity adsorption tests. The results of the concrete strength tests showed a slight difference in compressive strength and the same tensile strength performance when replacing a part of the cement by GP. However, after high temperature exposition, concrete with GP showed better performance than the reference concrete for temperature below 600℃. But, after heating at 800℃, the strength of the concrete with GP drop slightly more than reference concrete. This is accompanied by an important increase in mass loss and water porosity. After the microstructure analysis, no important changes happened differently for concrete with GP at high temperature except a new calcium silica form appears after the 800℃ heating.