• Title/Summary/Keyword: High Thermal Environment

Search Result 944, Processing Time 0.034 seconds

Characteristics of Toluene Destruction by Non-thermal Plasma in Packed with Catalyst Reactor (촉매가 충진된 플라즈마 반응기에서의 Toluene 제거특성)

  • 한소영;송영훈;차민석;김석준;최경일;신동준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2002
  • Destruction process of toluene using a wire-cylindrical BBD (Dielectric Barrier Discharge) reactor packed with catalysts was investigated to characterize the synergetic effects of non-thermal plasma and catalyst process. The catalysts used in the present study were ${\gamma}$-Al$_2$BO$_3$ and Pt/${\gamma}$-Al$_2$O$_3$. Under the numerous test conditions, specific energy density (SED (J/L)) and the conversion of toluene, defined as (1 -[C$_{f}$]/[C$_{i}$]), were measured. The test results showed that toluene decomposition efficiency followed the pseudo-first order in the case of plasma only process. The pseudo-first order process, however, was modified to pseudo-zeroth order reaction in the case of catalyst-assisted plasma process. This modification of the reaction order was verified based on a simple kinetic model proposed in the present study. Owing to the modification of reaction order, which resulted from the catalytic process, the specific energy to achieve the high removal efficiencies, i.e. 80~90%, was reduced significantly.y.y.

Formation Characteristics of Chlorobenzenes and Chlorophenols from TCE (TCE (trichloroethylene)으로부터 클로로벤젠과 클로로페놀의 생성특성)

  • 김은미;심영숙;이우근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.149-159
    • /
    • 2002
  • The objective of this study was to evaluate the formation characteristics of CBs and CPs from TCE, aliphatic compound. The experiment was carried out in a fixed reactor during 30 min under the oxidation condition at the range of temperature, 300~$700^{\circ}C$. MSWI fly ash was used as catalyst in this study. Total amount of CBs formed greater magnitude than that of CPs overall range of reaction temperature. It is proposed that the formation of CPs was caused from hydroxylation of CBs. According to increasing temperature to $600^{\circ}C$, the yield of CBs and CPs increased but significantly decreased at $700^{\circ}C$. It is suggested that decomposition rate was faster than formation rate at the high temperature. In the homologue distribution of CBs, DCBs were major products at 30$0^{\circ}C$ and the amount of higher chlorinated compound increased to $600^{\circ}C$. Because they were formed by chlorination of lower chlorinated compounds. In case of CPs, the amount of DCPs was 90% of total amounts in both thermal formation and catalytic reaction. On the other hand it was clearly observed that the chlorination rate in catalytic reaction was higher than in thermal formation with TCE only.

A study on the variation of skin temperature on the adult male at environment temperature (각 환경기온하에서의 성인남자 피부온에 관한 연구)

  • 심부자
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.71-88
    • /
    • 1996
  • For understanding skin temperature based on clothing design from a viewpoint of comfortable wearing, the skin temperature, physiological reactions(body temperature, blood pressure and pulse) and physilolgical response(thermal sensation, comfort sensation and perceptive sweaty sensation) were measured on condition tha t5 naked healthy male exposed to serveral environmental temperatures,( $20{\pm}1.0^{\circ}C$ ,$28{\pm}1.0^{\circ}C$ and $32{\pm}1.0^{\circ}C$). As the results of this testing, the regional skin temperature was varied for 90min just after expose to those the environment but was generally stabilized for the nest 90min. It was proved the difference of the regional skin temperature at low temperature environmental($20{\pm}1.0^{\circ}C$) was larger than at high temperature environmental($32{\pm}1.0^{\circ}C$) and inder serveral environmental temperature,the degree of the regional skin was not equal. Except in case of the thigh, the front of all regional skin temperature turned out higher than the back of them. According to change of environmental temperature, body temperature and pulse were altered. In the pshycological response, 'thermal sensation-comfort sensation' was felt to 'slightly warm - comfortable' at $28{\pm}1.0^{\circ}C$of the environmental temperature, and 'perceptive sweaty sensation', wneh it was said 'sweat' at only $32{\pm}1.0^{\circ}C$ of it.

  • PDF

Temperature Inversion off Wasaka Bay in the East Sea, June of 1995 and 1996

  • Lee Chung-Il;Cho Kyu-Dae;Yun Jong-Hwui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.55-59
    • /
    • 2004
  • Temperature inversion off Wasaka Bay in the East Sea was studied using data measured on a CREAMS cruise in June of 1995 and 1996. Temperature inversion occurred mainly at the upper layer of the thermocline at a depth of no more than 20 m and around the thermal front between the TWC and the coastal waters of Japan. At some stations. temperature inversion had an influence un density inversion, while, in some other stations, high salinity water prevented density inversion.

  • PDF

The sound insulation performance of eco-friendly loess brick wall (친환경 황토벽체의 차음성능 평가에 관한 연구)

  • Lee, Tai-Gang;Kim, Yul;Song, Kook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

Case for Detection and Prevention of Inflow Section for Contaminant through Annular Space in Borehole, Jeju Island (제주도 관정 공벽 내 오염물질 유입 구간 탐지 및 차단 사례)

  • Song, Sung-Ho;Hwangbo, Dongjun;Kim, Jin-Sung;Yang, Won-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2022
  • Most wells developed in Jeju island before the enactment of the Groundwater Management Ordinance in 2002 are vulnerable to aquifer contamination due to inflow of upper groundwater having the high concentration of nitrate nitrogen, likely due to incomplete grouting in upper section of the wells. Although these wells require entire reinstallation, it is often necessary to rehabilitate the existing wells due to various constraints. Therefore, to identified the inflow section of contaminants, the thermal level sensor (TLS) technique was firstly applied for three wells, which enables to monitor temperature variations in every 50 cm depth. Then, the grouting material was injected to the upper section to prevent the inflow of upper contaminated groundwater into the entire aquifer. By applying TLS technique, it was found that the temperature deviations in the upper groundwater inflow section decreased sharply. Moreover, both the change in the concentration of nitrate nitrogen in the rainy/dry seasons and the average concentrations were found to decrease rapidly after grouting material injection. Consequently, the application of TLS proposed in the study turned out to be appropriate to prevent aquifer contamination.

Dynamics of High Turbid Water Caused by Heavy Rain of Monsoon and Typhoon in a Large Korean Reservoir (Andong Reservoir) (인공호에서 몬순과 태풍 강우에 의한 고탁수층의 이동과 소멸특성)

  • Park, Jung-Won;Shin, Jae-Ki;Lee, Hee-Moo;Park, Jae-Chung
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.1 s.110
    • /
    • pp.105-117
    • /
    • 2005
  • During the period of heavy rain from 2002 to 2004, the characteristics of the inflow, temporal and spatial fluctuations of high turbid water according to thermal stratification were studied on the Andong Reservoir which is the largest artificial lake in the Nakdong River basin, Korea. Thermal stratification was formed in June. Its structure determined to the pathway of inflowing turbid water and has affected by the transportation of high turbid water. Regardless of the time and amount of inflow, the high turbid water showed the shape of underflow at the riverine zone, separated from the bottom at the transition zone and moved to the lacustrine zone with the shape of density current. The plunging point depended on the time and amount of inflow. The distributions of thermal stratification and DO concentrations were changed by inflowing discharge. Two thermoclines and minimum DO layers were found out existing at metalimnion in a specific time, respectively. The layer of high turbid water which formed with the thickness of 20 m at the maximum below the depth of 15 m moved toward dam. Not settled to the bottom, the newly formed layer was discharged through the intake-outlet and dispersed into all layers by the circulation in the fall.

A study on the Distance and Frequency Variable Characteristics of Flat Plate Induction Heating Element (평판 유도발열체의 거리·주파수 가변특성에 관한 연구)

  • Woo, Hyoung-Gyun;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.68-74
    • /
    • 2013
  • Induction-heated system is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. This technique is used high frequency inverter. By using high frequency inverter high frequency in the range of kHz can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed analysis of characteristics according to the each frequency and produced Flat plate induction heating system using 1.5kW-class half-bridge resonant inverter. In addition, operating characteristics of the system to changes in the distance between the coil and the heater, applications of system are also discussed.

The Electrical Properties of Fluorocarbon Polymer Composites with High Voltage Arc Resistance (초고압 내아크용 불소수지 복합재료의 전기적 특성)

  • 박효열;안명상;강동필
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.216-219
    • /
    • 1996
  • Polytetrafluoroethylene is very suitable for insulation materials because of it's high thermal and chemical stability, high electrical resistance and low loss factor. But almost all kinds of pure fluoroplastic cannot endure long time in the high temperature arc environment breaking high voltage and current In this study, inorganic materials such as BN, TiO$_2$ and Al$_2$O$_3$ were filled in the polytetrafluoroethylene to improve arc resistance. The electrical properties, arc resistant properties and light reflectance of the composites were investigated.

  • PDF

Highly Reliable White LEDs Using Nitride Phosphors

  • Xie, Rong-Jun;Hirosaki, Naoto;Takeda, Takashi
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.4
    • /
    • pp.375-379
    • /
    • 2012
  • Nitride phosphors are now attracting significant attention of material scientists and phosphor engineers, because they promise red-shifted photoluminescence spectra, small Stokes shift, high quantum efficiency and low thermal degradation. A number of interesting nitride phosphors have been developed and practiced for producing white light with LED chips. In this paper, the applications of nitride phosphors in highly reliable wLEDs will be overviewed.