• Title/Summary/Keyword: High Thermal Environment

Search Result 944, Processing Time 0.032 seconds

Thermal Stress Analysis on the Solid Oxide Fuel Cell according to Operating Temperature

  • Kwon, Oh-Heon;Kang, Ji-Woong;Jo, Se-Jin
    • International Journal of Safety
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • The fuel cell is one of the green energy receiving a lot of attention. Among the fuel cells, it is generally referred to SOFC(solid oxide fuel cell) which is made up composites of a solid. SOFC has excellent merits in the side of environment and energy. However because of the high operating temperature, it has economic loss by the using of expensive materials and problems of structural instability by thermal stresses. Therefore, this study aims to the effect of analysis by the FEMLAB. The results have deformations and the maximum stresses from the variation of the thickness of vulnerability spots. The deformation shows expansion as 0.82% and the stress ${\sigma}_{xx}$ is 392MPa in electrolyte and -56.31MPa in anode. When increasing or decreasing the thickness to 50% of the reference thickness about the electrolyte which is vulnerable spots.

  • PDF

Comparative Study of Polymerization Environment for Hydrogel Ophthalmic Lens

  • Kim, Duck-Hyun;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.696-701
    • /
    • 2018
  • This study is carried out to evaluate the commercial feasibility of the room temperature and thermal polymerization method as a lens manufacturing method. All samples are found to be transparent after polymerization, thereby indicating that their physical and surface properties are suitable for hydrogel ophthalmic lenses. The optical and physical properties of the lenses are compared. The water content of the samples that are prepared via a room temperature polymerization process decreases with the addition of MMA as compared to the water content of the samples that are prepared via thermal polymerization. When MMA and DMA are used as an additive for improving functionality, the wettability of the lenses increases. By measuring the AFM, the surface roughness is shown to improve more than MMA and DMA. Therefore, it is judged to be an appropriate process for manufacturing hydrogel lenses with high functionality.

Space Business and Applications of Vacuum Technology (우주개발과 진공기술의 응용)

  • Lee, Sang-Hoon;Seo, Hee-Jun;Yoo, Seong-Yeon
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.270-277
    • /
    • 2008
  • Vacuum is any air or gas pressure less than a prevailing pressure in an environmental or, specifically, any pressure lower than the atmospheric pressure and is used by a wide variety of scientists and engineering - including clean environment, thermal insulation, very long mean free path, plasma, space simulation[1]. The space environment is characterized by such a severe condition as high vacuum, and very low and high temperature. Since a satellite will be exposed to such a space environment as soon as it goes into its orbit, space environmental test should be carried out to verify the performance of the satellite on the ground under the space environmental conditions. A general and widely used method to simulate the space environment is using a thermal vacuum chamber which consists of vacuum vessel and thermally controlled shroud. As indicated by name of vacuum chamber, the vacuum technology is applied to design and manufacture of the thermal vacuum chamber. This paper describe the vacuum technology which is applied to space business.

A Study on the Effectiveness of Wind Corridor Construction forImproving Urban Thermal Environment: A Case study of Changwon, South Korea (도시 열환경 개선을 위한 취약지역 선정 및 바람길 조성 방안: 창원시를 대상으로)

  • Kim, Jong-Sung;Kang, Jung-Eun
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.4
    • /
    • pp.187-202
    • /
    • 2021
  • This study examined the effectiveness of wind corridor construction by analyzing the thermal environment, cold air generation, ventilation, and geographical characteristics to improve urban thermal environment and establish the basis for specialized strategy in Changwon-si, Gyeongsangnam-do. Using spatial analysis and remote sensing techniques, surface temperature, land cover and land use, wind field, and slope were measured and through this, a wind corridor analysis model was constructed. As a result of the analysis as of 2020, Changwon-si generally has land cover characteristics that are advantageous for the generation of cold air, but the temperature in most urban areas is the highest, and the temperature in areas such as north Changwon area, Jinbukmyeon, Ung-dong, and Ungcheon-dong are relatively high. There was a typical trend of high average wind speed in mountain regions and low average wind speed in urban areas. Accordingly, the north Changwon area, the former Changwon downtown area, the Hogye-ri and Pyeongseong-ri areas, and the Changpo Bay area are derived as vulnerable areas to thermal environment, and various measures to reduce temperature and improve air quality that the inflow of cold air into the area considering the characteristics of each area and securing wind ventilation between the surrounding mountains, reservoirs, and park areas were proposed.

Thermal Property Test of Natural Sand and Artificial Sand for the Design of Casting Process (주조공정 설계를 위한 자연주물사와 인공주물사의 열물성 시험)

  • Jeong-Ho Nam;Byoung-Jun Lee;Si-Young Kwak
    • Journal of Korea Foundry Society
    • /
    • v.44 no.1
    • /
    • pp.3-8
    • /
    • 2024
  • Reducing industrial waste and improving the atmospheric environment recently have emerged as important tasks for the casting industry. Various types of artificial sand that can replace natural sand have been developed and used to solve problems that arise with the use of conventional foundry sand and to improve the foundry environment. However, only limited physical properties provided by overseas suppliers are known and in-depth comparative analyses with existing natural sand are lacking. For the design of the casting process, a wide range of thermal properties must be secured not only at room temperature but also at high temperatures. In addition, it is important to compare and analyze the differences in thermal properties between existing natural and artificial sand because changes in thermal properties require changes in the design of the casting method. In this study, the thermal behavior of the mold was analyzed through a thermal expansion test of mold blocks for natural and artificial sand., To this end, a thermal property test to evaluate thermal conductivity was performed by determining a temperature range. The results of the experiment, revealed that the thermal conductivity was 5-40% higher in artificial sand than in natural sand, and the coefficient of thermal expansion was about 15% lower for artificial sand. However, there was not a significant difference in specific heat regardless of the composition.

Analyses on Thermal Stability and Structural Integrity of the Improved Disposal Systems for Spent Nuclear Fuels in Korea

  • Lee, Jongyoul;Kim, Hyeona;Kim, Inyoung;Choi, Heuijoo;Cho, Dongkeun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.21-36
    • /
    • 2020
  • With respect to spent nuclear fuels, disposal containers and bentonite buffer blocks in deep geological disposal systems are the primary engineered barrier elements that are required to isolate radioactive toxicity for a long period of time and delay the leakage of radio nuclides such that they do not affect human and natural environments. Therefore, the thermal stability of the bentonite buffer and structural integrity of the disposal container are essential factors for maintaining the safety of a deep geological disposal system. The most important requirement in the design of such a system involves ensuring that the temperature of the buffer does not exceed 100℃ because of the decay heat emitted from high-level wastes loaded in the disposal container. In addition, the disposal containers should maintain structural integrity under loads, such as hydraulic pressure, at an underground depth of 500 m and swelling pressure of the bentonite buffer. In this study, we analyzed the thermal stability and structural integrity in a deep geological disposal environment of the improved deep geological disposal systems for domestic light-water and heavy-water reactor types of spent nuclear fuels, which were considered to be subject to direct disposal. The results of the thermal stability and structural integrity assessments indicated that the improved disposal systems for each type of spent nuclear fuel satisfied the temperature limit requirement (< 100℃) of the disposal system, and the disposal containers were observed to maintain their integrity with a safety ratio of 2.0 or higher in the environment of deep disposal.

Thermal Comfort of the Sports/Leisure Clothing with the Heat Storage/Reflection Function - Wearing Evaluation under the Condition of 0x00B1;1℃ and 50±5% RH - (축열/체열반사기능을 가진 스포츠 레저복의 온열쾌적성 - 0±1℃, 50±5% RH 환경에서의 착의평가 -)

  • Kim, Tae-Gyou;Song, Min Kyu;Lee, Chang Min;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.474-481
    • /
    • 2018
  • For this study, we developed clothing in which textile materials that were excellent weather control function for the cold environment and we performed the human subject test with developed clothing to determine the thermal comfort. We used 2 clothing samples developed (A and B, hollow yarn+moisture absorption/quick drying yarn, 3 layers, high stretchable, heat reflection film and lamination treated) and a control sample (Ctrl.) for the human subject test and 8 adult males were used as a human subjects and environmental conditions of chamber were $0{\pm}1^{\circ}C$. $50{\pm}5%RH$, 0.3m/sec. The results were as follows: The average skin temperature and hand, thigh temperature of B were higher than B and Ctrl. (p<.05). The micro-climates of B were near to thermal comfort range which is $32{\pm}1^{\circ}C$ and $50{\pm}10%\;RH$. The chest temperature of B was significantly higher than others (p<.05). The relative humidity of B was lower than others and kept stable rather than others. The thermal sensation of B was near the "neutral" and was significantly different from Ctrl. (p<.01) and the weight loss of B was lower than Ctrl. (p<.05). The counting task and hand temperature was positively related and the counting task value of B and A is bigger than Ctrl. and that of A was bigger than Ctrl. (p<.05).

An Analysis on Micro-climate Characteristic of Apartments in Beijing, China Using ENVI-met Simulation (ENVI-met를 이용한 중국 베이징 아파트 하절기 미기후 특성 분석)

  • Wu, Jin-Dong;Lee, Jun-Hoo;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.169-176
    • /
    • 2019
  • The purpose of this study was to analyze outdoor thermal comfort of apartments planning characteristic of pedestrian height in Beijing, China. Selecting 322 apartment complexes with more than 1000 households and more than 10 buildings(including 10 buildings), mainly in Chaoyang District and Tongzhou District to select 32 basic layout types and then 12 typical layout types were select in 32 basic layout types. Finally, the simulation was conducted for the 12 typical layout types using the micro-climate model ENVI-met to evaluate the wind environment, the thermal environment and the comfort. The results of this study as follows: In the parallel arrangement, it has the best outdoor thermal comfort of Slab-East-Parallel(S/E/P). Next is Slab-South-Parallel(S/S/P), Tower-South-Parallel(T/S/P) in turn. In the stagger arrangement, Mixture-South-North and South Stagger-1(M/S/NSS-1) has the best outdoor thermal comfort and Slab-South-North and South Stagger(S/S/NSS), Tower-South-North and South Stagger(T/S/NSS), Mixture-South-North and South Stagger-3(M/S/NSS-3), Mixture-South-North and South Stagger-4(M/S/NSS-4), Mixture-South-North and South Stagger-2(M/S/NSS-2) in turn. In the cluster arrangement, Mixture-Mixture-Cluster-2(M/M/C-2) has the best outdoor thermal comfort and Mixture-Mixture-Cluster-3(M/M/C-3), Mixture-Mixture-Cluster-1(M/M/C-1) in turn. Due to the low wind speed and high air temperature, it is necessary to consider the layout types that can form the wind road at first, such as Mixture-South-North and South Stagger-1(M/S/NSS-1), Slab-South-North and South Stagger(S/S/NSS) and so on.

Axisymmetric vibration analysis of a sandwich porous plate in thermal environment rested on Kerr foundation

  • Zhang, Zhe;Yang, Qijian;Jin, Cong
    • Steel and Composite Structures
    • /
    • v.43 no.5
    • /
    • pp.581-601
    • /
    • 2022
  • The main objective of this research work is to investigate the free vibration behavior of annular sandwich plates resting on the Kerr foundation at thermal conditions. This sandwich configuration is composed of two FGM face sheets as coating layer and a porous GPLRC (GPL reinforced composite) core. It is supposed that the GPL nanofillers and the porosity coefficient vary continuously along the core thickness direction. To model closed-cell FG porous material reinforced with GPLs, Halpin-Tsai micromechanical modeling in conjunction with Gaussian-Random field scheme is used, while the Poisson's ratio and density are computed by the rule of mixtures. Besides, the material properties of two FGM face sheets change continuously through the thickness according to the power-law distribution. To capture fundamental frequencies of the annular sandwich plate resting on the Kerr foundation in a thermal environment, the analysis procedure is with the aid of Reddy's shear-deformation plate theory based high-order shear deformation plate theory (HSDT) to derive and solve the equations of motion and boundary conditions. The governing equations together with related boundary conditions are discretized using the generalized differential quadrature (GDQ) method in the spatial domain. Numerical results are compared with those published in the literature to examine the accuracy and validity of the present approach. A parametric solution for temperature variation across the thickness of the sandwich plate is employed taking into account the thermal conductivity, the inhomogeneity parameter, and the sandwich schemes. The numerical results indicate the influence of volume fraction index, GPLs volume fraction, porosity coefficient, three independent coefficients of Kerr elastic foundation, and temperature difference on the free vibration behavior of annular sandwich plate. This study provides essential information to engineers seeking innovative ways to promote composite structures in a practical way.

Evaluation of Thermal Conductivity of Porous TiO2-SiO2-Base Thermal Insulation (다공성 TiO2-SiO2 복합 단열재의 열전도율 평가)

  • Choi, Byugchul;Kim, Jon-Ho;Kim, Jon Beom;Jung, Woonam;Lee, Sang-Hyun
    • Journal of Institute of Convergence Technology
    • /
    • v.8 no.1
    • /
    • pp.21-25
    • /
    • 2018
  • We developed nano-porous $TiO_2-SiO_2$ composites (commercial name : PTI, porous titania insulator) with low thermal conductivity as thermal insulating material as well as function of photocatalyst. The objectives of this paper are, firstly, to evaluate of the thermal conductivity of the PTI powder in the temperature range from -160 to $250^{\circ}C$, secondly to evaluate of thermal conductivities of insulation materials that is applied PTI powder. The structure of the PTI powder that has the pores size of 20-30 nm and the particle diameter of 2-10 nm. The PTI had a high surface area of $400m^2/g$ and a mean pore size of $45{\AA}$, which was fairly uniform. The thermal conductivity was measured by GHP(guarded hot plate) method and HFM(heat flux method). The PTI structure is a three-dimensional network nano-structures composed by a pearl-necklace that involved a precious stone in the center of the necklace. The thermal conductivities of PTI-PX powder by the GHP and HFM were 0.0366 W/m.K, 0.0314 W/m.K at $20^{\circ}C$, respectively. This is similar to values that are proportional to the square of the absolute temperature of the thermal conductivity of static air. The thermal conductivities of insulating sheets coated with PTI powder were similar results with that of the PTI powder.