• Title/Summary/Keyword: High Temperature Superconducting Generator

Search Result 33, Processing Time 0.027 seconds

Comparison of superconducting generator with 2G HTS and MgB2 wires

  • Park, S.I.;Kim, J.H.;Le, T.D.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.48-52
    • /
    • 2013
  • This paper compares the features of second generation (2G) High Temperature Superconducting (HTS) field coil with those of magnesium diboride ($MgB_2$) field coil for a 10 MW class superconducting generator. Both coils can function effectively in their respective magnetic flux density range: 10-12 T for 2G HTS field coil, 2 T for $MgB_2$ superconducting field coil. Even though some leading researchers have been developing 10 MW class superconducting generator with 2G HTS field coil, other research groups have begun to focus on $MgB_2$ wire, which is more economical and suitable for mass production. However 2G HTS wire is still appealing in functions such as in-field property and critical temperature, it shows higher in-field property and critical temperature than $MgB_2$ wire.

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

  • Chae, Yoon Seok;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.1-6
    • /
    • 2020
  • This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 W HTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

AC Loss Analysis of 10 MW Class Fully High Temperature Superconducting Synchronous Generators with Dual Field Windings (이중계자를 갖는 10 MW급 전초전도 동기 발전기의 교류손실 해석)

  • Park, Sang Ho;Lee, Myeonghee;Lee, Seyeon;Yang, Hyung Suk;Kim, Woo-Seok;Lee, Ji-Kwang;Choi, Kyeongdal
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.467-472
    • /
    • 2020
  • The superconducting synchronous generator is one of the breakthrough elements for direct-drive wind turbines because it is light and small. Normally the superconducting one has copper armature windings in the stator and superconducting field windings on the rotor. The high resistance of the armature can make large copper losses, comparing with the conventional generators with a gear box. One of the solutions for the large copper losses could be a fully superconducting generator. But the high magnetic fields from the superconducting field windings on the rotor also make high perpendicular magnetic fields on the superconducting tapes in the armature windings. We have proposed a fully superconducting synchronous generator with dual field windings. It could immensely decrease the circumferential component of the magnetic field from the field windings at the armature windings. In this paper, we conceptually designed 3 types of superconducting synchronous generators. The first one is the fully superconducting one with conventional structure, which has superconducting armature windings in the stator and superconducting field windings on the rotor. The second one is the one with dual superconducting field windings and superconducting armature windings between them. The last one is the same as the third one except the structure of the armature. If the concentrated armature windings are superconducting ones with cryostats, then they cannot be installed within the span of 2 poles. So, we adopted 3 phases windings within 4 poles system. It makes more AC losses but can be manufactured really.

Electromagnetic design of 10 MW class superconducting wind turbine using 2G HTS wire

  • Kim, J.H.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.29-34
    • /
    • 2013
  • This paper introduces design processes of 10 MW class superconducting generator for wind Turbine. Superconducting generator can produce 5 times stronger magnetic field than permanent magnet at least, which enables large scale wind turbine to function as a lighter, smaller and more highly efficient system. These processes are targeted for higher efficiency and shorter high temperature superconductor (HTS) wires to fabricate 10 MW class superconducting generator. Three different approaches will be described in these design processes. First design process focuses on the number of rotor poles. Secondly, 270 and 360 A operating current of superconducting field coil can be adapted as a design parameter in this process. Lastly, 3 and 6 kV line to line voltage of stator coil will be used to design 10 MW class superconducting generator.

Optimal Design of a MW Class SCSG for a Tidal Current Power Generation System

  • Go, Byeong-Soo;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2271-2276
    • /
    • 2015
  • A superconducting synchronous generator (SCSG) can be expected to decrease the size and weight compared to conventional tidal current generators. This paper proposes an optimal design of a 2 MW class SCSG for a tidal current power generation system. The proposed optimal design of the SCSG will reduce the length of the high-temperature superconducting wire as well as the weight and volume of the SCSG. The 3D finite element method is used to analyze the magnetic field distribution. The optimized 2 MW SCSG is compared with a 2 MW conventional generator. As the optimized SCSG is more compact and lighter than a conventional generator, it will be efficiently applied to practical tidal power systems.

3D electromagnetic design and electrical characteristics analysis of a 10-MW-class high-temperature superconducting synchronous generator for wind power

  • Kim, J.H.;Park, S.I.;Le, T.D.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.47-53
    • /
    • 2014
  • In this paper, the general electromagnetic design process of a 10-MW-class high-temperature superconducting (HTS) synchronous generator that is intended to be utilized for large scale offshore wind generator is discussed. This paper presents three-dimensional (3D) electromagnetic design proposal and electrical characteristic analysis results of a 10-MW-class HTS synchronous generator for wind power. For more detailed design by reducing the errors of a two-dimensional (2D) design owing to leakage flux in air-gap, we redesign and analyze the 2D conceptual electromagnetic design model of the HTS synchronous generator using 3D finite element analysis (FEA) software. Then electrical characteristics which include the no-load and full-load voltage of generator, harmonic contents of these two load conditions, voltage regulation and losses of generator are analyzed by commercial 3D FEA software.

Design and Electromagnetic Analysis of a 15 MW Class Superconducting Wind Power Generator (15 MW급 초전도 풍력 발전기의 설계 및 전자기 해석)

  • Jung, Ga-Eun;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.39-44
    • /
    • 2019
  • A high-temperature superconducting(HTS) generators have been actively studied because of its advantages of weight, size, and efficiency. A large-scale superconducting wind power generator becomes a very low-speed high-torque rotating machine. In these machines, high electromagnetic force and torque are important issued. Two generators connected in series on one shaft design are one of the solution to overcome the high torque problem. In this paper, the authors design and analyze a 15 MW class HTS generator. The 15 MW HTS generator is confirmed in terms of magnetic field distribution and torque performance using a 3D finite element method. As a result, the designed generators generates less torque than a conventional generator. The designed 15 MW superconducting generator will be effectively utilized in the construction of the large-scale wind power generation system.

Analysis of Magnetic Field of Superconducting Winding According to the Changed Damper Thickness and Material (댐퍼의 두께와 재질 변화에 따른 초전도 선재에 미치는 자장특성 분석)

  • Jeong, Jae-Sik;Lee, Sang-Ho;Hong, Jung-Pyo;Jo, Young-Sik
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.5-8
    • /
    • 2012
  • Superconducting windings of synchronous machine have to be operated in below the critical temperature, critical current density and critical magnetic field. If one of these characteristics does not satisfied, then the quench occurred in superconducting winding. Especially the armature current dramatically increased as the superconducting generator is short-circuited at the rated load condition and magnetic field in field winding increased due to the armature current. Therefore, damper is required to reduce the magnetic field of field winding which increases reliability of the superconducting generator. Damper dimension can be decided by time constant[1-2]. In this paper the basic model is high-power and low-speed superconducting generator. Damper time constant was calculated from the changed damper thickness and material. Magnetic flux of field coil at the basic model and changed damper time constant model is analyzed.

Fault characteristic analysis of a modularized HTS field coil-based 12 MW class SCSG (모듈화된 계자코일을 가지는 12 MW급 초전도 발전기의 고장 특성 분석)

  • Go, Byeong-Soo;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1108-1109
    • /
    • 2015
  • In general, when a high-temperature superconducting (HTS) field coil breaks down, the overall field coils of a superconducting synchronous generator (SCSG) are also stopped working, because of the HTS field coils are connected in series. Therefore, the HTS field coils have to be modularized. The modularized HTS field coil is operated individually. Therefore, even if the HTS field coils are broken-down, the generator still operates under the fault conditions. But the output power and torque of the generator will be affected. This paper deals with the fault characteristics analysis of a 12 MW class SCSG with the modularized HTS field coils when the coils were broken-down. The steady-state and transient state characteristics of the modularized 12 MW class SCSG were analyzed and compared. The fault characteristics analysis results of the 12 MW class superconducting generator for the wind turbines were discussed in detail.

  • PDF

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.