• 제목/요약/키워드: High Temperature Measurement

검색결과 1,525건 처리시간 0.03초

Effect of High-Temperature Spinning and PVP Additive on the Properties of PVDF Hollow Fiber Membranes for Microfiltration

  • Cha, Bong-Jun;Yang, Jung-Mok
    • Macromolecular Research
    • /
    • 제14권6호
    • /
    • pp.596-602
    • /
    • 2006
  • The effect of high-temperature spinning and poly(vinyl pyrrolidone) (PVP) additive on poly(vinylidene fluoride) (PVDF) hollow fiber membranes was investigated using differential scanning calorimetry, X-ray diffraction measurement, and scanning electron microscopy, together with the corresponding microfiltration performances such as water flux, rejection rate, and elongational strength. Using high-temperature spinning, porous hollow fiber membranes with particulate morphology were prepared through PVDF crystallization. The particulate structure of the membranes was further modified by the addition of miscible PVP with PVDF. Due to these effects, the rejection rate and strength of the fibers were increased at the expense of reduced water flux and mean pore size, which indicates that high-temperature spinning and PVP addition are vary effective to control the morphology of PVDF hollow fiber membranes for microfiltration.

분압용 세라믹 적층 소자를 이용하 정밀 고전압 계측 시스템 (Precise High Voltage Measurement System Using Ceramic Stack Element for Voltage Divider)

  • 윤광희;류주현;박창엽;정영호;하복남
    • 한국전기전자재료학회논문지
    • /
    • 제13권5호
    • /
    • pp.396-401
    • /
    • 2000
  • In order to accurately measure the high voltage of 22.9[kV] power distribution lines we investigated the temperature dependence of measuring voltage on the number of stack layers in the voltage measurement system made from single and stack voltage divider capacitors (22, 44, 66 layers, respectively). Temperature coefficient of dielectric constant(TC$\varepsilon_{{\gamma}}$/)of voltage divider capacitors which were fabricated by BaTi $O_3$system ceramics showed the variations from -2.28% to +1.69% in the range of -25[$^{\circ}C$] ~50[$^{\circ}C$]) was decreased with increasing of stack number and the stack element of 66 layers showed the least error of $\pm$0.87%or of $\pm$0.87%.

  • PDF

지중 전력케이블용 반도전재료의 이온성 불순물에 따른 흡습 및 열적특성 (Absorption and Thermal Properties According to Ionic Impurities of Semiconductive Materials for Underground Power Cable)

  • 이경용;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.133-137
    • /
    • 2004
  • In this paper, we investigated impurities content, absorption properties, and thermal properties showing by changing the content of carbon black which is semiconductive materials for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Impurities content of specimens and absorption properties were measured by ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometer) and Karl Fisher. And high temperature, heat degradation initiation temperature, and heat weight loss were measured by TGA (Thermogravimetric Analysis). The dimension of measurement temperature was 0$[^{\circ}]$ to 800$[^{\circ}]$, and rising temperature was 10$[^{\circ}/min]$. Impurities content was highly measured according to increasing the content of carbon black from this experimental result also absorption amount was increased according to these properties. Specially, impurities content values of the A1 and A2 of existing resins were measured more than 4000[ppm]. Heat degradation initiation temperature from the TGA results was decreased according to increasing the content of carbon black. All over, heat stabilities were EEA>EBA>pEVA. That is, heat stabilities of EVA containing the weak VA(vinyl acetate) against heat was measured the lowest.

  • PDF

유동층습도계와 아스만습도계의 비교 연구 (Comparative Study of Fluidized Bed-type and Assmann Psychrometer)

  • 강희찬;강민철
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

적외선 카메라를 이용한 압축성 고속 충돌 제트에서의 단열 벽면 온도 특성 연구 (Measurement of Adiabatic Wall Temperature in Compressible High Speed Impinging jets using Infra-red Camera)

  • 김범석;신상우;유만선;조형희;이장우;배주찬
    • 한국항공우주학회지
    • /
    • 제35권8호
    • /
    • pp.714-719
    • /
    • 2007
  • 본 연구에서는 적외선(Infra-Red) 카메라를 이용하여 원형 노즐을 통한 고속 제트 분사 시 수직 충돌 벽면에서 나타나는 정상상태(steady state)의 단열 벽면 온도를 2차원적으로 측정하였다. 출구 노즐 직경으로 표현된, Reynolds 수 187,000에서 노즐-평판간 거리 변화의 영향을 살펴보았으며, 측정된 단열 벽 온도는 회복 계수로 무차원화 하였다. 한편 열전대를 이용하여 측정한 단열 벽면 온도를 적외선 카메라를 이용한 측정 결과와 비교하여 검증하였다.

인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구 (Development of Radiation Thermometer using InSb Photo-detector)

  • 황병옥;이원식;장경영
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용 (Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating)

  • 박철규;유호선
    • 플랜트 저널
    • /
    • 제17권1호
    • /
    • pp.50-57
    • /
    • 2021
  • 수력학적 효율측정 방법만으로는 펌프시스템 부속장치들의 개별효율 및 펌프 자체효율을 명확하게 산출해내기 매우 어렵다. 이에 본 연구에서는 국내 최초로 지역난방 중온수용 펌프시스템에 최신 열역학적 펌프 효율측정방법을 도입, 수력학적 방법과의 효율 병행측정 결과를 검토하였고, 그 결과 기존 수력학적 펌프효율 측정방법만으로는 데이터 불확실성이 높은 반면, 열역학적 및 수력학적 방법 병행측정 데이터를 적용한 펌프 및 유체커플링 효율값은 상호보완적 역할수행에 의해 펌프성능 측정방법의 신뢰성 및 적정성이 검증되는 의미 있는 결과를 도출할 수 있었다. 또한, 지역난방시스템에 열역학적 펌프효율 측정방법을 적용한 결과, 최대 120 ℃ 고온 환경에도 불구, 매우 안정적인 데이터 측정 및 측정장비의 내구성이 검증되는 등 열역학적 측정방법의 신뢰성을 검증할 수 있었다.

크랙에 의한 고온 초전도체 테이프의 임계전류 특성변화 (The variation of critical current by the formation of crack in a high-temperature superconducting tape)

  • 박을주;설승윤
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.73-77
    • /
    • 2002
  • The variation of critical current by the formation of crack in a high temperature super-conducting tape was studied by experimental and numerical analyses. The current-voltage relation of HTS tape is measured by the four-point measurement method. Numerical analyses are used to solve two dimensional heat conduction equation, considering the temperature distribution. By comparing current-voltage relation of experimental and numerical results, the validity of numerical method is verified.

공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정 (Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures.)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF