Operating Characteristics of Internal Heat Exchanger for $CO_2$ Geothermal Heat Pump in the Heating Mode (난방모드 시 $CO_2$ 지열히트펌프의 내부열교환기에 대한 운전특성)

  • Kim, Jae-Duck;Lee, Sang-Jae;Kim, Seon-Chang;Kim, Young-Lyoul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1226-1231
    • /
    • 2009
  • This paper presents operating characteristics of internal heat exchanger(IHX) for $CO_2$ geothermal heat pump in the heating mode. Mass flow rate of $CO_2$, inlet temperatures of $CO_2$ at high and low pressure side were selected as main effect factors by using fractional factorial DOE(Design of Experiments). And RSM(Response Surface Method) was used in optimization phase. The results show that heat transfer rate of IHX increases when either inlet temperature of low pressure side decreases or inlet temperature of high pressure side increases. Effectiveness of IHX increases with increasing of inlet temperature of either high pressure side or low pressure side. Finally, performance contour map was provided over the operation ranges of the main design factors.

  • PDF

Characteristics Analysis of the Heat Exchange Rate according to Soil Temperature and Grout Material using Numerical Simulation

  • Oh, Jin Hwan;Nam, Yu Jin
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.29-36
    • /
    • 2014
  • The ground source heat pump (GSHP) system has attracted much of attention, because of its stability of heat production and the high efficiency of the system. Performance of the heat exchanger is dependent on the soil temperature, the ground thermal conductivity, the operation schedule, the pipe placement and the design temperature. However, in spite of the many variables of these systems, there have been few research on the effect of the systems on system performance. In this study, analysis of the heat exchange rate according to soil temperature and grout material was conducted by numerical simulation. Furthermore, the heat distribution around the ground heat exchanger was presented on the different conditions of grout and underground temperature by the simulation.

Computer Simulation of a Super-Heat Pump System (고효율 수퍼히트펌프에 관한 전산 해석)

  • Kim, H.J.;Jung, D.S.;Kim, C.B.;Ha, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

Numerical Study of the Performance Characteristics of a Cascade Heat Pump Water Heater at Low Ambient Temperatures (저온 외기조건에서 케스케이드 급탕열펌프의 성능특성에 관한 해석적 연구)

  • Song, Jaehyun;Jung, Haewon;Park, JaeWoo;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.225-232
    • /
    • 2013
  • Heat pump systems have been widely adopted in buildings for cooling and heating, due to their higher energy efficiency. Recently, the demand for hot water supply from the heat pump system has been increasing. To increase the water supply temperature with higher system efficiency and reliability, a heat pump water heater adopting cascade cycle was investigated in this study. The cascade heat pump water heater consisted of a low-stage cycle using R410A, and a high-stage cycle using R134a. A simulation program for the cascade heat pump water heater was developed, and verified by comparison with experimental data. The performance of the cascade heat pump water heater was optimized, by varying the compressor rotating speeds of the low- and high-stage cycles. At low ambient temperatures, the performance of the cascade cycle was compared with that of the single-stage cycle. The system efficiency of the cascade cycle was higher than that of the single-stage cycle, showing a lower compression ratio and compressor discharge temperature.

A Study on the Dehumidification effect of Adsorbent at low Temperature (저온에서 흡착제의 제습효과에 대한 연구)

  • Lee, Min-Seok;Jeong, Yun-Ho;Lim, So-Min;Heo, Jae-Woo;Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.177-182
    • /
    • 2020
  • Interest in heat pumps is increasing as an eco-friendly and energy-saving heating method. In particular, in order to develop a heat pump capable of heating in a low-temperature area, research to prevent frost on the surface of the outdoor unit is increasing. In other words, when heating through a heat pump in a low-temperature area, a frost layer is formed on the surface of the outdoor unit, which lowers the heat transfer performance, thereby reducing the heating capacity. Therefore, in this study, an adsorption-type dehumidification system is attached to remove the moisture vapor of the air into the outdoor unit of the heat pump. It is believed that this study can suggest the most effective dehumidification method in low temperature regions. In addition, it is expected that a heat pump with high energy efficiency can be developed by attaching an adsorption dehumidifying system to the front of the outdoor unit of the heat pump.

Performance Evaluation of a $CO_2$ Heat Pump System for Fuel Cell Vehicles (연료전지 자동차용 이산화탄소 열펌프 시스템의 성능평가)

  • Kim, Sung-Chul;Park, Jong-Chul;Kim, Min-Soo;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • The global warming potential (GWP) of $CO_2$ refrigerant is 1/1300 times lower than that of R134a. Furthermore, the size and weight of the automotive heat pump system can decrease because $CO_2$ operates at high pressure with significantly higher discharge temperature and larger temperature change. The presented $CO_2$ heat pump system was designed for both cooling and heating in fuel cell vehicles. In this study, the performance characteristics of the heat pump system were analyzed for heating, and results for performance were provided for operating conditions when using recovered heat from the stack coolant. The performance of the heat pump system with heater core was compared with that of the conventional heating system with heater core and that of the heat pump system without heater core, and thus the heat pump system with heater core showed the best performance among the selected heating systems. On the other hand, the heating performance of two different types of coolant/air heat pump systems with heater core was compared each other at various coolant inlet temperatures. Furthermore, to use exhausted thermal energy through the radiator, experiments were carried out by changing the arrangement of a radiator and an outdoor evaporator, and quantified the heating effectiveness.

An Experimental Study on the Performance of a Heat Pump for the Cold Climate (한랭지용 열펌프의 저온난방 성능에 관한 실험적 연구)

  • Ju Jeong-Dong;Bae Kyung-Su;Hwang Young-Kyu;Lee Yun-Yong;Jeong Gyoo-Ha;Oh Sang-Kyong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.39-46
    • /
    • 2005
  • The present study concerns an experimental study of a R-22 heat pump system consisted of liquid and liquid heat exchangers. The test was performed for various systems of a single-, tandem-, and two stage-cycle at the same environmental conditions of temperature. Various experiments of the heat pump system were peformed to compare the heating capacity and COP, when the outdoor temperature is near $-15^{\circ}C$ and the indoor temperature is $20^{\circ}C.$ As the results of the present study, the system of Tandem(parallel) cycle showed the best heating performance, while the discharge temperature of refrigerant was too high. In case of the system of two stage cycle, the performance characteristics were significantly improved by employing the inter cooler.

The Study of Validity on the High Temperature Heat Pump System using Dyeing Wastewater (염색폐수를 이용한 고온수 히트펌프 시스템 타당성 연구)

  • Kim, Jeong-Yeol;Chung, Dong-Yeol;Park, Shung-Sang;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.996-1001
    • /
    • 2009
  • The purposes of this work were suggested and validated the methods of heat recovery from dyeing wastewater exhausted in Sihwa and Banwol dyeing industrial park. We analyzed the present conditions of heat supplies and demands. So it was made a selection of the system combined heat exchanger for waste heat recovery and the high temperature heat pump. We decided the specifications of the heat recovery facilities. After this, economical assessment is performed to this system. The payback periods are within 4 years, 20 years and 5 years in case of K company, S company and A company. In addition, when they are produced the heat of same capacity, quantities of pollutants from used fuels were calculated.

  • PDF

Effects of Grouts and Temperature Change on Microorganisms in Geothermal Heat Pump (지열시스템의 그라우트 및 수온변화가 미생물에 미치는 영향 실험)

  • Jo, Yun-Ju;Lee, Jin-Yong;Kim, Chang-Gyun;Han, Ji-Sun
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.10-14
    • /
    • 2009
  • Objective of this study was to examine the effects of grouts and temperature change on microorganisms in geothermal heat pump. Groundwater samples were obtained from wells in the heat pump system during installation (Oriental medicine hospital) and in the heat pump system under operation (Business incubation center). Grouts are the volclay sodium bentonite. Real-time PCR was used to evaluate total bacterial number and 16S rDNA. The results showed that total bacterial number of groundwater in the heat pump operation was greater than that of non-operation case, which indicates a temperature effect on the bacterial culture. In addition, high concentration of grout showed an elevated bacteria number. In the mean time, a long-term field monitoring is essentially required to confirm the effects of the grouts and the temperature changes.

A Study on the Performance Evaluation of Combined Heat Pump System according to the Ratio of Ground Heat Source and Water Heat Source (지열원 및 수열원 비율에 따른 복합열원 히트펌프시스템 성능 평가 연구)

  • Park, Sihun;Ko, Yujin;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.11-19
    • /
    • 2021
  • In this study, combined heat source heat pump system was implemented with 4 single heat source heat pumps each applied with a geothermal source and a water source. Five cases (Case1~Case5) were configured to conduct a performance comparison and analysis of the combined heat source heat pump system. First of all, as a result of analyzing the heat source, the case when 4 ground heat sources were applied (Case1) showed a uniform EST(Entering Source Temperature) distribution throughout the year since it is less affected by outside air compared to the case when 4 water heat sources were applied (Case5). In both winter and summer, the ground heat source maintained higher EST than the water heat source. Therefore, the system with high ratio of geothermal sources is advantageous for heating, and with high ratio of water heat sources is advantageous for cooling.