• Title/Summary/Keyword: High Temperature Heat Pump

Search Result 172, Processing Time 0.028 seconds

A Study on the Production of Hydrogen by 2-Propanol Dehydrogenation (2-프로파놀의 탈수소화에 의한 수소제조 연구)

  • Sim, Kyu-Sung;Kim, Jong-Won;Kim, Youn-Soon;Park, Ki-Bae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.1
    • /
    • pp.11-16
    • /
    • 1995
  • Chemical heat pump is one of the energy conversion technologies, which enables to use waste heat as a source of high grade heat. In 2-propanol/acetone system, the dehydrogenation of 2-propanol is an endothermic(heat absorption) reaction, and can be used to generate hydrogen because 2-propanol can be converted to acetone and hydrogen at low temperature(about $8^{\circ}C$) using catalyst. For the dehydrogenation of 2-propanol 5% Ru catalyst based on activated carbon is the best one at the reaction temparature of $83^{\circ}C$.

  • PDF

Heating and Cooling System for Utilization of Surplus Air Thermal Energy in Greenhouse and its Control Logic

  • Yang, Seung-Hwan;Lee, Chun-Gu;Lee, Won-Kyu;Ashtiani, Alireza Araghi;Kim, Joon-Yong;Lee, Sang-Deok;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • Purpose: Utilizing air thermal energy during over-heated time in the greenhouse is a necessary component to save greenhouse heating costs for nighttime. However, there is no practical way to implement the related principles. Methods: In this study, a heating and cooling system which utilizes the surplus air thermal energy in a greenhouse was developed. Available air thermal energy and heating load for this experimental glasshouse were estimated based on temperature conditions of the plant growth and weather data. Results: Estimated values were 400 MJ/day for maximum surplus air thermal energy and 340 MJ/day for maximum heating energy which were target values of the design as well. The system consists of a heat pump, fan-coil units and heat storage tanks which are divided into low and high temperature tanks. Moreover, a new control logic was developed for surplus air thermal energy utilization. Conclusions: This paper explains the details of conceptual design process of the system. Results of test operations showed that the developed system performed the recovery and supply of the thermal energy according to design purposes.

Study on the performance analysis of SCW geothermal system by simulation and monitoring (모니터링 및 시뮬레이션을 통한 SCW형 지열 시스템의 성능인자 분석에 관한 연구)

  • Lee, SangJun;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.8-15
    • /
    • 2013
  • Recently, an interest in the use of renewable energy has been growing up due to the rise of raw material price, international oil price and depletion of fossil energy. Ground source heat pump system has a high efficiency by using the constant temperature of underground and various types of the systems have been installed and utilized in the building. there are few studies on the system performance factors in the SCW system. Furthermore, even though the performance of the system depends on the temperature of heat source, the research on their relationship is rare. In this research, in order to analyze the performance factor for the open-loop system the monitoring of the real building with the standing column well systems and the simulation with building model were conducted.

Water-Cooling System of HVDC System (HVDC 시스템의 수냉식 냉각 시스템)

  • 김찬기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.257-267
    • /
    • 1999
  • This paper deals with the water cooling system of HVDC(High Voltage Direct CUlTentJ. It is generally accepted that water is a veη effective medium to remove heat losses from any type of equipment. Because of this benefits the water cooling method is used in HVDC. The water cooling system consists of a heat exchanger, circulation pump and a connecting pipe. According to thYI1stor temperature level. thyristor junction temperature is controlled by controlling the f fan of exchanger. In this paper. the water cooling system of HVDC system is analyzed and estimated.

  • PDF

FEASIBILITY OF AN INTEGRATED STEAM GENERATOR SYSTEM IN A SODIUM-COOLED FAST REACTOR SUBJECTED TO ELEVATED TEMPERATURE SERVICES

  • Koo, Gyeong-Hoi;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1115-1126
    • /
    • 2009
  • As one of the ways to enhance the economical features in sodium-cooled fast reactor development, the concept of an integrated steam generator and pump system (ISGPS) is proposed from a structural point of view. And the related intermediate heat transfer system (IHTS) piping layout compatible with the ISGPS is described in detail. To assure the creep design lifetime of 60 years, the structural integrity is investigated through high temperature structural evaluation procedures by the SIE ASME-NH computer code, which implements the ASME-NH design rules. From the results of this study, it is found that the proposed ISGPS concept is feasible and applicable to a commercial SFR design.

Combustion Characteristics of High Pressure Gas Generator for Liquid Rocket Engine (액체로켓엔진용 가스발생기의 고압연소특성)

  • Han Yeoung-Min;Lee Kwang-Jin;Moon Il-Yoon;Seo Seong-Hyeon;Choi Hwan-Seok;Lee Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.341-345
    • /
    • 2005
  • This paper is for the combustion characteristics of gas generator which drive 1.5MW-class turbo pump and runs in fuel-rich combustion regime with LOx/kerosene as propellant. The outline of development procedure of real scale high pressure gas generator is introduced and the relation between O/F ratio and outlet temperature and the molecular weight and specific heat ratio of combustion gas are described. The relation between O/F ratio and temperature is newly obtained at higher pressure and the molecular weight and specific heat ratio is modified and their validity is confirmed by the mass relation equation.

  • PDF

Prediction model of 4.5 K sorption cooler for integrating with adiabatic demagnetization refrigerator (ADR)

  • Kwon, Dohoon;Kim, Jinwook;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2022
  • A sorption cooler, which utilizes helium-4 as a working fluid, was previously developed and tested in KAIST. The cooler consists of a sorption pump and a thermosyphon. The developed sorption cooler aims to pre-cool a certain amount of the magnetic refrigerant of an adiabatic demagnetization refrigerator (ADR) from 4.5 K to 2.5 K. To simulate the high heat capacitance of the magnetic refrigerant, liquid helium was utilized not only as a refrigerant for the sorption cooling but also as a thermal capacitor. The previous experiment, however, showed that the lowest temperature of 2.7 K which was slightly higher than the target temperature (2.5 K) was achieved due to the radiation heat leak. This excessive heat leak would not occur when the sorption cooler is completely integrated with the ADR. Thus, based on the experimentally obtained pumping speed, the prediction model for the sorption cooler is developed in this study. The presented model in this paper assumes the sorption cooler is integrated with the ADR and the heat leak is negligible. The model predicts the amount of the liquid helium and the required time for the sorption cooling process. Furthermore, it is confirmed that the performance of the sorption cooler is enhanced by reducing the volume of the thermosiphon. The detailed results and discussions are summarized.

Heat-Pressure Characterization of Power Steering Hose by Finite Element Analysis (자동차 파워스티어링 호스의 열내압 특성 유한요소해석)

  • Roh, Gi-Tae;Joen, Do-Hyung;Choi, Ju-Hyung;Cho, Jin-Rae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.409-414
    • /
    • 2003
  • Power steering hose is device that operation oil passes between steering gear box and oil pump by parts that is used to do steering system. Because this hose is receiving heat and pressure of high temperature, leakage can produce swaging from hitch of steel materials of done part. In this paper, we analyze swaging process of Power steering hose by finite element analysis, and achieved thermal and pressure analysis with this shape. We can analogize weakness part of hose through this result, and examine closely oil leakage and rubber failure mechanism and look for important design benevolence of power steering hose development.

  • PDF

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Air-side Heat Transfer and Pressure Drop of a Fin-and-Tube Heat Exchanger Under Low Temperature Condition (저온 조건에서 핀-관 열교환기의 공기측 열전달 및 압력손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.15-20
    • /
    • 2017
  • Currently, residential air conditioners operate as a heat pump during winter. In this case, the outdoor heat exchanger acts as an evaporator obtaining heat from cold air. On the other hand, it acts as a condenser during summer transferring heat to hot air. The outdoor temperature changes significantly from high to low. Generally, the air-side j and f factors are obtained at a standard outdoor temperature. Therefore, the applicability of the j and f factors under different outdoor conditions needs to be checked. In this study, tests were conducted for a two-row louver finned heat exchanger changing the outdoor temperature to subzero. The effects of the tube-side brine flow rate were also checked. The results showed that air-side j and f factors were essentially constant and independent of the outdoor temperature, suggesting that an extension of j and f factors obtained under standard conditions to a low outdoor temperature is acceptable. All j and f factors agreed within 9% and 3%, respectively. Tests were also conducted by changing the coolant flow rate. Both the j and f factors did not change according to the flow rate, suggesting that the tube-side heat transfer correlation is acceptable.