• Title/Summary/Keyword: High Pressure Oil Filter

Search Result 12, Processing Time 0.032 seconds

Fabrication of Stable Water/Oil Separation Filter Using Effect of Surface Wettability (표면 젖음성을 이용한 물/오일 분리막 제작)

  • Kim, Dohyeong;An, Taechang
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.213-217
    • /
    • 2016
  • The superhydrophobic and superoleophobic meshes surfaces have been used in various applications such as self-cleaning, anti-icing, gas exchange, oil-water separation, sound-wave penetrable anti-wetting structures, etc. In particular, there are many studies for oil-water separation with environmental issues. Because of high pressure and dynamic environment, oil-water separation filters must have stable surface properties as super-hydrophobicity and superoleophobicity. The oleophobicity of surface depends on the surface chemistry and roughness of the surface. The roughness of oleophobic surface enhances its static contact angle and stability. The multi-scale hierarchical structure provides a stable superhydrophobic state by maintaining a Cassie state. In this research, we fabricated a superoleophobic mesh with a multi-scale hierarchical structure to increase the pressure resistance and adjusted a size of the mesh hole.

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

Influence of Driving Pattern on Regeneration Performance of Continuously Regenerating Diesel Particulate Filter (연속재생 DPF의 재생 성능에 미치는 차량 운행패턴의 영향)

  • Hwang, Jin-Woo;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.5
    • /
    • pp.358-364
    • /
    • 2009
  • This paper is to investigate the influence of driving patterns of slow and high speed vehicles on the performance of continuously regenerating diesel particulate filter(DPF) system matched with operating conditions in field application. The DPF performance test for field application was carried out for two identical DPFs installed to slow and high speed vehicles. A slow speed vehicle was selected among local buses which have driving patterns to repeat running and stop frequently, while a high speed vehicle was prepared to have long route of high speed over 60km/h like inter-city buses. In this test, the regeneration performance on the DPF of slow speed vehicle deteriorated because of high soot load index(SLI) in spite of same balance point temperature(BPT) distribution for high speed vehicle. The DPF of slow speed vehicle melted in the end because the rapid increase of back pressure caused high temperature over $1200^{\circ}C$ in the ceramic wall of DPF. The PM components like ash collected to the filter in the DPF were analyzed in order to investigate the cause of the defect and provide an operation performance of DPF system. In the result of the analysis, high levels of lubrication oil ash(Ca, Mg, P, Zn) were detected.

A study of improving filtration efficiency through SiC whisker synthesis on carbon felt by CVD VS method

  • Kim, Gwang-Ju;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.150-150
    • /
    • 2016
  • Mankind is enjoying a great convenience of their life by the rapid growth of secondary industry since the Industrial Revolution and it is possible due to the invention of huge power such as engine. The automobile which plays the important role of industrial development and human movement is powered by the Engine Module, and especially Diesel engine is widely used because of mechanical durability and energy efficiency. The main work mechanism of the Diesel engine is composed of inhalation of the organic material (coal, oil, etc.), combustion, explosion and exhaust Cycle process then the carbon compound emissions during the last exhaust process are essential which is known as the major causes of air pollution issues in recent years. In particular, COx, called carbon oxide compound which is composed of a very small size of the particles from several ten to hundred nano meter and they exist as a suspension in the atmosphere. These Diesel particles can be accumulated at the respiratory organs and cause many serious diseases. In order to compensate for the weak point of such a Diesel Engine, the DPF(Diesel Particulate Filter) post-cleaning equipment has been used and it mainly consists of ceramic materials(SiC, Cordierite etc) because of the necessity for the engine system durability on the exposure of high temperature, high pressure and chemical harsh environmental. Ceramic Material filter, but it remains a lot of problems yet, such as limitations of collecting very small particles below micro size, high cost due to difficulties of manufacturing process and low fuel consumption efficiency due to back pressure increase by the small pore structure. This study is to test the possibility of new structure by direct infiltration of SiC Whisker on Carbon felt as the next generation filter and this new filter is expected to improve the above various problems of the Ceramic DPF currently in use and reduction of the cost simultaneously. In this experiment, non-catalytic VS CVD (Vapor-Solid Chemical Vaporized Deposition) system was adopted to keep high mechanical properties of SiC and MTS (Methyl-Trichloro-Silane) gas used as source and H2 gas used as dilute gas. From this, the suitable whisker growth for high performance filter was observed depending on each deposition conditions change (input gas ratio, temperature, mass flow rate etc.).

  • PDF

Protection against Aerosols by particulate Respirators and Fit Performance (방진마스크의 에어졸 방어효과와 밀착정도)

  • 한돈희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.30-36
    • /
    • 2001
  • This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.

  • PDF

SIMULATION OF A HYDRAULIC CONTROL SYSTEM FOR POWERSHIFT TRANSMISSION OF TRACTORS

  • Kim, D. C.;Lee, H. S.;Kim, K. U.;Y S. Nam
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.498-505
    • /
    • 2000
  • Performance of a hydraulic system is influenced by its working temperature. Therefore, it is very important to make the system perform uniformly in an entire range of the working temperature. In this study a simulation of a hydraulic control system for the powershift transmission of tractors was conducted and the effect of the temperature was investigated in terms of design conditions of the system. Results of the simulation are as follows. The hydraulic control system with a spring accumulator was found to be more convenient to control the shifting time than that with a gas accumulator. By returning the oil from the clutches to the system through a path between the filter and pump, the time delay due to the pressure difference between the low and high temperatures could be reduced. Therefore, it was recommended that the hydraulic control system for the powershift transmission of tractors must be equipped with a spring accumulator and a circuit to return oil from the clutches to the system through a path between the filter and pump.

  • PDF

An Experimental Study on Spray Characteristics of Diesel and Bio-diesel Fuel (디젤 및 바이오디젤 연료의 분무특성에 관한 연구)

  • Kim, Jae-Duk;Ainull, Ghurri;Song, Kyu-Keun;Jung, Jae-Yeon;Kim, Hyung-Gon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.53-59
    • /
    • 2011
  • The using of diesel engine will be increased in the world for fuel economy. But diesel engine emits harmful emissions such as much NOx, smoke etc. In this study, experiments were performed to investigate the spray characteristics of diesel spray in a common-rail system according to fuel temperature, injection pressure, injection period and fuel viscosity etc. using a high speed video camera. Diesel oil has different spray patten due to injection pressure and injection period in a common-rail system. A Filter pressure was influenced by fuel temperature which was turned to fuel viscosity related to a fluid flowing. The effect of the bio-diesel fuel mixing ratio on the spray and atomization characteristics was also investigated at various experimental conditions. It shows that the droplet atomization characteristics of bio-diesel fuel showed deteriorated results as the mixing ratio of biodiesel increased because of the high viscosity.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation (PVC필터에 채취된 절삭유의 손실에 관한 연구)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.451-457
    • /
    • 2001
  • Because liquids with high molecular weight such as mineral oil have low vapor pressure at room temperature, it is generally thought to be difficult to lose them to evaporation. However, when they are dispersed into air in small droplets during application in machining processes, their surface area becomes considerably higher. To determine the potential for metalworking fluids (MWF) filter losses, MWF mist was generated and collected on polyvinyl chloride (PVC) filters in test chamber. After collected MWF was exposed to clean air during designated period (range 10~240 minutes) and the filters were desiccated, losses were evaluated. As duration of clean air passing through PVC filter increased, loss of MWF gradually increased. MWF lost after 10 minutes ranged form 12.4 % to 21.8 % of the original loading mass, on average 53.3 % of the total loss. These results indicate that significant mass of MWF collected on PVC filters can be lost at the beginning of air sampling. Loss of MWF collected on PVC filter also occurred during desiccation without active airflow. In multiple regression to identify which factors influence the loss of MWF collected on PVC filter, both duration of air passing through PVC filter and MWF age (fresh vs. used) were significant predictor (p=0.0001). Therefore, workers' exposure to MWF measured method 0500, may underestimate true concentration. Further study is needed to develop a new method to quantify the workers' exposure to airborne MWF mist accurately.

  • PDF