• Title/Summary/Keyword: High Power Pulse Generator

Search Result 126, Processing Time 0.028 seconds

Sine-wave and Trigger Pulse Generator for SS-OCT (SS-OCT용 정현파 및 트리거 펄스 발생기)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.398-403
    • /
    • 2015
  • In this paper, the sine-wave and trigger pulse generator with capability of frequency high-resolution and time-variable trigger edge has implemented. It fulfills well the requirements for SS-OCT with frequency resolution of 1 Hz, frequency stability of ${\leq}{\pm}0.03Hz$ and time-variable trigger edge. Through its performance test applied to the wavelength swept laser, 90 nm, sweeping range and 10mW average optical power were obtained. This showes that the realized generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Development of A High Voltage Generator for EP Adopting the Micro-Pulse Concept (Micro-Pulse 하전식 집진기용 초고압 전원장치 개발)

  • Kim, W.H.;Kang, I.;Kim, J.S.;Rim, G.H.;Kim, J.W.;Cho, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2130-2132
    • /
    • 1998
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. EP is usually used for air cleaning in the coal power plant. One of the key technology in the EP is high voltage pulse power supply, which affects the performance of the overall system. In this study, high voltage micro pulse power supply for the EP is developed for a 500MW coal power plant. The power supply has a dc source and a pulse one. The ratings of the dc and pulse source are 60kV, 800mA and 70kV, 400mA respectively.

  • PDF

Study of PD Location in Generators by PD Pulses Propagation

  • Cheng, Yang-Chun;Li, Cheng-Rong;Wang, Wei
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.252-256
    • /
    • 2006
  • When a partial discharge takes place at the stator of a generator, the electrical pulse will propagate along the stator bars and the capacitor chains formed by the end part of the stator winds. On the first path, the pulse propagates as a travel wave at slow speed. On the second path, the pulse propagates at quick speed. Based on the data of the experiments on a real 50 MW steam generator, the author has found the pulses can propagate by magnetic field of the stator winding. It was studied that how to locating the partial discharge by signals coming from the different paths, including the features of signals on the two paths at time domain and frequency domain, the measurement frequency rang of the signals, the blind area, the advantage and disadvantage of this method.

Pulsed Power Modulator based on IGBTs (IGBT 기반 고압 펄스전원장치)

  • Ryoo, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.43-46
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is important for series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used. Proposed scheme has lots of advantages such as long lifecyle, compact size, flat topped pulse forming, small weight, protection for arc, high efficiency and flexibility to generate various kinds of pulse output.

  • PDF

Experimental Study on Conducted EMI Mitigation in SMPS using a Novel Spread Spectrum Technique

  • Premalatha, L.;Raghavendiran, T.A.;Ravichandran, C.
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.619-625
    • /
    • 2013
  • Switched mode power supplies (SMPS) are power electronic circuits extensively used in a wide range of applications. High frequency switching operation of SMPS causes electromagnetic emissions and has the potential to interfere with system operation, which in turn has an impact on system performance. This makes electromagnetic compatibility (EMC) an important concern. In this paper, a new and simple spread spectrum technique is proposed by modulating chaotic pulse position modulation (CPPM) and pulse width modulation (PWM). The resulting CPWM is implemented to reduce the conducted EMI in SMPS. The proposed method is found to be effective in reducing conduction EMI. The effectiveness and simplicity of the proposed method on spreading those dominating frequencies is compared to the EMI mitigation technique using an external chaotic generator. Finally, the levels of conductive EMI with standard PWM, CPWM with an external chaos generator and the proposed method are experimentally verified to comply with the CISPR 22A regulations. The results confirm the effectiveness of the proposed method.

HIPIMS Arc-Free Reactive Deposition of Non-conductive Films Using the Applied Material ENDURA 200 mm Cluster Tool

  • Chistyakov, Roman
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.96-97
    • /
    • 2012
  • In nitride and oxide film deposition, sputtered metals react with nitrogen or oxygen gas in a vacuum chamber to form metal nitride or oxide films on a substrate. The physical properties of sputtered films (metals, oxides, and nitrides) are strongly influenced by magnetron plasma density during the deposition process. Typical target power densities on the magnetron during the deposition process are ~ (5-30) W/cm2, which gives a relatively low plasma density. The main challenge in reactive sputtering is the ability to generate a stable, arc free discharge at high plasma densities. Arcs occur due to formation of an insulating layer on the target surface caused by the re-deposition effect. One current method of generating an arc free discharge is to use the commercially available Pinnacle Plus+ Pulsed DC plasma generator manufactured by Advanced Energy Inc. This plasma generator uses a positive voltage pulse between negative pulses to attract electrons and discharge the target surface, thus preventing arc formation. However, this method can only generate low density plasma and therefore cannot allow full control of film properties. Also, after long runs ~ (1-3) hours, depends on duty cycle the stability of the reactive process is reduced due to increased probability of arc formation. Between 1995 and 1999, a new way of magnetron sputtering called HIPIMS (highly ionized pulse impulse magnetron sputtering) was developed. The main idea of this approach is to apply short ${\sim}(50-100){\mu}s$ high power pulses with a target power densities during the pulse between ~ (1-3) kW/cm2. These high power pulses generate high-density magnetron plasma that can significantly improve and control film properties. From the beginning, HIPIMS method has been applied to reactive sputtering processes for deposition of conductive and nonconductive films. However, commercially available HIPIMS plasma generators have not been able to create a stable, arc-free discharge in most reactive magnetron sputtering processes. HIPIMS plasma generators have been successfully used in reactive sputtering of nitrides for hard coating applications and for Al2O3 films. But until now there has been no HIPIMS data presented on reactive sputtering in cluster tools for semiconductors and MEMs applications. In this presentation, a new method of generating an arc free discharge for reactive HIPIMS using the new Cyprium plasma generator from Zpulser LLC will be introduced. Data (or evidence) will be presented showing that arc formation in reactive HIPIMS can be controlled without applying a positive voltage pulse between high power pulses. Arc-free reactive HIPIMS processes for sputtering AlN, TiO2, TiN and Si3N4 on the Applied Materials ENDURA 200 mm cluster tool will be presented. A direct comparison of the properties of films sputtered with the Advanced Energy Pinnacle Plus + plasma generator and the Zpulser Cyprium plasma generator will be presented.

  • PDF

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

Low Cost Signal Generator with Frequency High-Resolution for SS-OCT (SS-OCT용 고 주파수분해능 저비용 정현파 발생기)

  • Lee, Juchan;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.84-88
    • /
    • 2013
  • In this paper, the low price signal generator with capability of frequency high-resolution and variable sync pulse has implemented. It fulfils well the requirements for SS-OCT of the frequency resolution less than 1Hz, frequency stability of ${\leq}{\pm}0.5Hz$/10 min and variable sync pulse output timing. Through its performance test applied to wavelength swept laser, 120 nm sweeping range and 10 mW average optical power were obtained. This shows that the realized sine-wave generator can replace the commercial high cost and high performance signal generators employed by current SS-OCT systems.

200 kV 50 ns Coaxial Type Mini Marx Generator (200 kV, 50 ns급 동축형 Mini Marx 펄스발생장치)

  • Lee, Sang-Woog;Lee, Chae-Min;Chang, Yong-Moo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.481-482
    • /
    • 2008
  • We have designed a Marx Generator, named EMD Pulse Generator(EPG), which makes steep front high voltage, 50ns rise time and 200kV high. It was designed as coaxial type and in small size, 70cm high and 20cm in diameter. The firing system is trigatron type and the spark gap switches in each stage are coaxial with the axis of the system. In this paper we mention about the characteristics of EPG and several experimental data.

  • PDF