• Title/Summary/Keyword: High Performance Building

Search Result 1,836, Processing Time 0.032 seconds

Analysis Performance of Super Window through Simulation and Verification Experiment (시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석)

  • Peak, Sang-Hun;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Sung, Uk-Joo;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

An experimental study on the Performance Evaluation of High Performance Polyurea Resins (고성능 폴리우레아 수지의 기본적 물리/화학적 성능평가에 관한 실험적 연구)

  • Kim, Yun-Ho;Choi, Eun-Kyu;Seo, Hyun Jae;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.43-45
    • /
    • 2011
  • As technologies evolve, building large concrete structures ever built, but due to lack of maintenance after completion of concrete corrosion, leaks, and preparedness from the problem that is an urgent need. In particular, water-resistant variety of concrete structures. How the concept applies to the most important public drinking water purification and drinking water that is draining the production and storage, and distribution as the structure cause damage to the structure when the contaminated water is supplied to each home that can harm the health of citizens is the cause. Therefore, the correct choice of materials, and thorough a lot of investment in construction and maintenance should have. In this study, unlike conventional water-proof materials, methods, and in other reactions easily than conventional poly-urea resins have good physical performance and chemical resistance, high performance polyurea resin performance review of the physical infrastructure of the country for the longevity of would like to make long-term durability.

  • PDF

An experimental study on the fragility factor of high strength concrete (고강도 콘크리트의 취도계수에 관한 실험적 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Performance of Mature and Matriculation Entry Students Studying Towards the National Diploma in Building at the University of Johannesburg, South Africa

  • Wellington Didibhuku Thwala
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.647-652
    • /
    • 2011
  • Developments in the teaching of the National Diploma in Building students should be geared towards meeting the needs of the construction industry in South Africa. These needs are usually in the form of skills and knowledge required to resolve thorny issues encountered in practice. The lack of capacity in the construction industry needs to be addressed from the basis of ensuring that the education system caters for both mature entry and matriculation entry students. The paper looks at a comparison in performance between mature entry and matriculation (just finish High School) entry students focusing on the National Diploma in Building students at the University of Johannesburg. The paper will make a comparison between those students who work first before enrolling for their first year National Diploma in Building and those who are directly from high school. Cooperative education involves training and systematically developing students through the acquisition of the requisite skills, attitudes, values and knowledge required to adequately perform in their chosen careers. The paper describes the problems and experiences that have been encountered by both mature and matriculation entry students in their three years of study which affects their performance. The paper will then look at the value of prior experience in enabling students to finish their National Diploma in Building within a three year period. The paper closes with some recommendations for the future.

  • PDF

The Study of Load Test Method for In-Site Casting Pile In High Rise Building. (초고층에서의 현장타설말뚝 재하시험방법 고찰)

  • Kim, Dae-Hak;Hong, Young-Kil;Han, Sung-Moo;Gu, Ung-Hwoe;Park, Chan-Duck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.385-392
    • /
    • 2008
  • Modern city have had a lot of high-rise building in high standards and multi-level performance. Using of city space reach better stages by using integration. These skyscraper have increased working load on ground. that building is efficiently designed for that soil capacity is well applied. With material side, big size pile, high strength concrete and high strength steel is used for that getting enough lobby space and resisting load increased of high-rise building. limit load test and load transmitted test can make soil capacity optimized. By the way, method of measuring pile capacity is more advanced and bigger. pile type applied by high rise building have underground excavation space, also reflect regional soil property and have some fact reviewed. A lot of high rise building recently is built as land mark in Seoul, Busan and Incheon. about method of measuring capacity of foundation pile, example of construction field is compared and reviewed.

  • PDF

A study on the evaluation of field application for the waterproofing or corrosion proof construction method, as coating high quality filtration plant with ozone resistance paints of phenol degeneration polyamine (페놀 변성 폴리아민계 내오존도료를 이용한 고도정수처리장의 방수$\cdot$방식 공법에 대한 현장 적용성 평가에 관한 연구)

  • Jung Mun-Jung;Kwon Shi-Won;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • It is applied in the high quality equipment construction by introduction of this high duality treating technology (ozone treating, activated carbon treating, high quality oxidation treating, UV treating etc.)waterproofing or corrosion proof method caused secondary economy damage of operation discontinuance and high quality treating equipment for applying existent waterproofing method that corrosion proof ability (ozone resistance performance, chemical resistance etc.) and abrasion resistance performance by comprehension insufficiency of user and designer. Therefor, In this study, we will analyze problem of waterproofing and corrosion material of existing construction application by high quality treating, and measure physical performance change by various condition. It is required to waterproofing and corrosion system and application of the field valuation.

  • PDF

A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete (초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구)

  • Baek, Young-Woon;Yuk, Tae-Won;Park, Dong-Soo;Kim, Han-Sol;Lee, Hang-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

Data Standardization of Construction Performance for Optimized Process Management in High-rise Curtain-wall Operations (초고층 커튼월 공정관리 최적화를 위한 건설성능 데이터 표준화)

  • Lee, Tae-Hee;Ko, Yong-Ho;Kim, Young-Suk;Han, Seung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.283-284
    • /
    • 2012
  • High-rise building construction has been increasing for the recent years and the construction process has become more complicated. This suggests a need for precise planning based on reliable data to prevent cost overruns and delays. However, the process planning is implemented based mainly on the experience of engineers that can result in critical damage in cost and time. Accurate productivity estimation and unit cost analysis must be considered important matter to prevent such disaster. This study estimates productivity and unit cost of curtain wall operations in high-rise building construction by simulation techniques and statistical methodologies. This study suggests a decision making methodology for the site personnel that enables to compare various combinations of productivity and unit cost based on reliable data that has been collected in actual construction sites. It is expected that this study contributes to the following research of developing an optimized construction performance assembling model for the site personnel.

  • PDF

Structural Design of Nakanoshima Festival Tower

  • Okada, Ken;Yoshida, Satoshi
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.173-183
    • /
    • 2014
  • Nakanoshima Festival Tower is a 200 m high-rise complex building which contains a renewed 2700-seat capacity concert hall known as "Festival Hall" and offices including headquarter of a news company. In order to build up an office tower on the hall which requires large open space, a giant truss system is employed. The giant trusses being composed of mega-trusses and belt-trusses support all the building weight above them and transfer the load to the outside of the hall. The building also requires high seismic resistance performance for a news company. Application of mid-story seismic isolation enables the building to satisfy high-level seismic resistance criteria.