• Title/Summary/Keyword: High Performance Building

Search Result 1,853, Processing Time 0.033 seconds

A Study on the Optimum Mix Proportion for Early Strength of Concrete in the Upper Layers of High Rise Building (Part II - 80MPa) (초고층 빌딩용 상층부 콘크리트의 조기강도 확보를 위한 최적배합 도출에 관한 연구 (Part II - 80MPa를 중심으로))

  • Jeon, In-Ki;Park, Yong-Kyu;Lee, Joo-Hun;Choi, Myung-Hwa;Yoon, Gi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.325-328
    • /
    • 2008
  • Recently increasing interest in high-rise building around the world for more than 100 floor, the trend is the increasing use of high-strength and high-flowable concrete so as of productivity improvements and cost savings to improve the performance of the early strength development. This study is to reach the optimal combination by reviewing the performance of high-rise building which is required. The results, lower the ratio of W/B was an increase in compressive strength and early strength in the use of admixture decreased in the combination of higher replacement ratio of admixture.

  • PDF

An Evaluation of High Performance Sunlighting Mirror Systems (고성능 태양광 채광시스템의 채광성능평가)

  • Kim, J.T.;Hwang, M.K.;Chung, Y.G.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.49-59
    • /
    • 2002
  • Recently, due to high rise building by rapid urbanization, the spaces incapable of being penetrated by sunlight into interior is increasing. So, sunlighting systems are important means to be able to get sunlight into indoors and to make sure of sunshine awareness. This study aims to evaluate lighting performance of sunlighting mirror systems. As results. these are very useful for the increase of an average illuminance of indoors and the penetration of sunlight. Especially, the second reflecting mirrors can be applied to spaces lack of sunlight. And these sunlighting systems developed in the present study is validated physical and psychological performance to both building and people.

Evaluation of NOx Removal Amount of UHPC with Titania fixed by Sieving-Vibration & Painting Methods (체가름-진동 및 페인팅에 의해 이산화티탄이 고정된 UHPC의 NO제거량 평가)

  • Kim, Byoung-Il;Oh, Sang-Keun;Kim, Soo-Yeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.193-194
    • /
    • 2021
  • Ti-salt agglomerated titanium dioxide photocatalyst from sludge, which has various and excellent functions such as nitrogen oxide removal performance, antifouling performance, and bacteria removal performance, is intended to be applied to UHPC. The UHPC used in this study is supposed to have a high compressive strength of 100~200MPa and a high flowability of 600mm or more with a slump flow. Titanium dioxide is fixed to the UHPC surface by sieving through a test sieve and compaction and painting using a vibration compactor, and this is tested according to ISO 22197-1. The NO removal amount is evaluated by classification the result range.

  • PDF

Economic Evaluation of Building Micro-Grid Including Geothermal Energy System in Hospital Buildings (지열시스템이 포함된 빌딩마이크로그리드 시스템의 에너지성능평가 및 경제성분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.273-277
    • /
    • 2009
  • This paper presents a basic energy performance data of micro gas turbine, Renewable Energy(BIPV and Solar Collector System, geothermal system) and a hybrid energy system(geothermal system and microturbine) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently, the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. Finally, in energy performance aspect, Micro gas turbine system and hybrid energy system were high-efficiency system in hospital building. Hybrid energy system also give us a powerful alternative energy system economically.

  • PDF

Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building (대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구)

  • Jeong, Dong-Hwa;Byun, Jae-Ki;Choi, Young-Don;Cho, Sung-Hwan
    • New & Renewable Energy
    • /
    • v.4 no.3
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

Architecture Study for SDDC BAS (SDDC BAS의 아키텍처에 관한 연구)

  • Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.646-651
    • /
    • 2015
  • In this paper, we analyze the architecture of a typical building automation systems and control points in the network architecture, interoperability, and performance aspects. We proposed a new virtualization-based point-to-point automatic control system that is connected to a high speed wired system. Cloud computing based automation system enables the user based environment control, and may perform a building energy management performance through the improvement of the building automation system efficiently In addition, the virtualization system makes it possible to perform the management of the group building load management operators efficiently.

Performance Based Seismic Design - State of Practice 2012 in the United States of America

  • Klemencic, Ron;Fry, J. Andrew;Hooper, John;Baxter, Robert;Morgen, Brian;Solberg, Kevin;Zaleski, Krzysztof
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.149-154
    • /
    • 2012
  • This paper presents a summary of the state of the practice for Performance Based Seismic Design (PBSD) in the United States. While it is not included in the prescriptive provisions of the United States' building codes, the PBSD procedure has been successfully implemented for two decades. The recent publication of the Guidelines for Performance-Based Seismic Design of Tall Buildings by the Pacific Earthquake Engineering Research Center (PEER) illustrates the fact that the engineering community has embraced this procedure and provides a thoughtful set of recommendations to building designers who intend to implement PBSD. The key parameters currently required for a PBSD also are outlined, such as seismic hazard definition, modeling procedures, and acceptance criteria. These Guidelines will serve as the basis for many PBSD projects in the coming years and as such are a common reference used throughout this paper. Finally, a brief summation of recent PBSD projects in the United States is presented.

Mechanical behavior test and analysis of HEH sandwich external wall panel

  • Wu, Xiangguo;Zhang, Xuesen;Tao, Xiaokun;Yang, Ming;Yu, Qun;Qiu, Faqiang
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.153-162
    • /
    • 2022
  • Prefabricated exterior wall panel is the main non-load-bearing component of assembly building, which affects the comprehensive performance of thermal insulation and durability of the building. It is of great significance to develop new prefabricated exterior wall panel with durable and lightweight characteristics for the development of energy-saving and assembly building. In the prefabricated sandwich insulation hanging wall panel, the selection of material for the outer layer and the arrangement of the connector of the inner and outer wall layers affect the mechanical performance and durability of the wall panels. In this paper, high performance cement-based composites (HPFRC) are used in the outer layer of the new type wall panel. FRP bars are used as the interface connector. Through experiments and analysis, the influence of the arrangement of connectors on the mechanical behaviors of thin-walled composite wall panel and the panel with window openings under two working conditions are investigated. The failure modes and the role of connectors of thin-walled composite wallboard are analyzed. The influence of the thickness of the wall layer and their combination on the strain growth of the control section, the initial crack resistance, the ultimate bearing capacity and the deformation of the wall panels are analyzed. The research work provides a technical reference for the engineering design of the light-weight thin-walled and durable composite sandwich wall panel.

Review of Freeform Buildings using CNC T-BAR System (CNC T-BAR 형상제어 시스템을 활용한 비정형 건축물의 곡면 파사드의 시공사례 검토)

  • Kim, SungJin;Park, YoungMi;Park, JungJoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.58-59
    • /
    • 2017
  • Through the case study, we surveyed the performance of a CNC-T BAR system on irregular-shaped building construction project. By CNC T-BAR system, we mean a surface curvature control system has been used in aircraft and ship manufacturing by controlling entire surface points on shape. For the past 10 year, the number of irregularly-shaped building design and construction project has been increased, and also the studies on irregular-shaped construction methods have been conducted. However, the previous studies did not review on the performance of the CNC T-BAR system. We collected construction-completed cases in Korea, which applied the CNC T-BAR system, and we studied its performance by comparing with a segment system in terms of construction duration and its quality. The result shows that the CNC T-BAR system can shorten the construction duration comparing with segment-assembly system while maintaining high quality. The CNC T-BAR system is expected to apply on the more number of irregularly-shape building construction project.

  • PDF

The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings (Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석)

  • Hwang, Woo-Jin;Kim, Kyo-Joon;Choi, Won-Ki
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF