• Title/Summary/Keyword: High Intensity

Search Result 4,606, Processing Time 0.032 seconds

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

자기 공명 영상의 고신호 구역에 관한 오공약침 치료의 임상적 연구

  • Lim, Jeong-A;Lee, Sung-Yong;Na, Won-Min;Moon, Hyung-Cheol;Yoo, Kwan-Suk;Kim, Sung-Chul
    • Journal of Pharmacopuncture
    • /
    • v.9 no.3 s.21
    • /
    • pp.37-46
    • /
    • 2006
  • Objective : This study was designed to find out the effect of scolopendrid aquacupuncture on low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging. Methods : The 30 patients who had a diagnosis of high intensity zone by lumbar-MRI and admitted to Gwangju oriental medical hospital in wonkwang university from January 2005 to August 2004 were observed. The symptom of inpatients is low back pain with or without sciatica. We treated 30 patients by scolopendrid aquacupuncture besides the general conservative treatment of oriental medicine. Results and Conclusion : The scolopendrid aquacupuncture treatment led to improvement in the pain and symptom of disability as determined by all efficacy measures. After scolopendrid aquacupuncture treatment, there was improvement in VAS, ROM and SLRT. This results suggest that scolopendrid aquacupuncture is good method for treatment of low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging.

Acoustic Characteristics of High Intensity Focused Ultrasound for Necrosis of CTO (CTO 괴사를 위한 고강도 집속 초음파의 음향학적 특성)

  • Park, Chan Hee;Jeong, Sang Hwa
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.481-488
    • /
    • 2015
  • It is difficult to see a therapeutic effect from cardiovascular disease treatment methods in the case of a hardened chronic total occlusion (CTO), owing to the calcification of the deposition materials. However, lesion cells, such as CTOs, can be selectively necrotized without affecting the normal tissue using high-intensity ultrasound focused on one point. In this study, a phantom CTO was necrotized by a high-intensity focused ultrasound (HIFU) energy system, and the acoustic characteristics in the focal region were analyzed. An experimental HIFU device was constructed to discover the appropriate conditions for the necrosis of a phantom CTO. The transfer characteristics of the ultrasound changed in the focal region by the density difference of the phantom CTO. These changes were acoustically analyzed to choose the available frequency band for each density. On-off temperature control in the focal region was applied to prevent rapid temperature rises, which would otherwise affect normal tissue.

Effects of turbulence intensity and exterior geometry on across-wind aerodynamic damping of rectangular super-tall buildings

  • Quan, Y.;Cao, H.L.;Gu, M.
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.185-209
    • /
    • 2016
  • Across-wind aerodynamic damping ratios are identified from the wind-induced acceleration responses of 15 aeroelastic models of rectangular super-high-rise buildings in various simulated wind conditions by using the random decrement technique. The influences of amplitude-dependent structural damping ratio and natural frequency on the estimation of the aerodynamic damping ratio are discussed and the identifying method for aerodynamic damping is improved at first. Based on these works, effects of turbulence intensity $I_u$, aspect ratio H/B, and side ratio B/D on the across-wind aerodynamic damping ratio are investigated. The results indicate that turbulence intensity and side ratio are the most important factors that affect across-wind aerodynamic damping ratio, whereas aspect ratio indirectly affects the aerodynamic damping ratio by changing the response amplitude. Furthermore, empirical aerodynamic damping functions are proposed to estimate aerodynamic damping ratios at low and high reduced speeds for rectangular super-high-rise buildings with an aspect ratio in the range of 5 to 10, a side ratio of 1/3 to 3, and turbulence intensity varying from 1.7% to 25%.

The Effects of Task Difficulty Controlled by Surface Condition During Bridging Exercise on Relative Multifidus Activation Ratio (교각 자세 운동 시 지지면 불안정성을 통한 과제 난이도가 다열근의 선택적 근활성도 비에 미치는 영향)

  • Song, Eun-Ju;Choi, Jong-Duk
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.59-66
    • /
    • 2011
  • The purpose of this study is to examine the activity ratios of global trunk muscles and local trunk muscles in relation to adjustments in the level of task difficulty while performing stability exercises in easily applied bridging lumbar stabilization exercise. Twenty healthy subjects performed bridging lumbar stabilization exercise while the level of task difficulty was plate was used in the same posture for all the exercises. EMG was used to examine the activity ratios of the global muscles and multifidus in relation to the level of task difficulty. Moreover, the activity ratios of the multifidus muscle, the erector spinae and the gluteus maximus muscle were measured. A one-way ANOVA with repeated measures was used, and a Bonferroni correction was conducted (${\alpha}$=.05). When the bridging lumbar stabilization exercise were performed at different difficulty levels, the activity of the multifidus muscle, which is a local muscle, was high in all three exercises. Also, compared to low intensity and intermediate intensity exercises, high intensity exercises showed more significant differences (${\alpha}$=.05). Among all the muscles, the multifidus showed the highest activity at intermediate intensity. Based on these results, we suggest that in the case of bridging lumbar stabilization exercise, low intensity or intermediate intensity exercises are more suitable and efficient for local muscle stabilization.

Research on Physical Characteristics of Chinese College Students of Different Physical Activity Levels

  • Li, Chuang;Long, Qianwen;Song, Jeho
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.334-341
    • /
    • 2020
  • Through a investigation of the physical activity status of 1794 undergraduates who were non-sports majors from freshman to senior in Jiangxi Normal University, to analyze physical fitness status of college students with different physical activity levels. The results showed that in physical activity, high-intensity physical activity of male was higher than female, while medium-intensity and low-intensity (insufficient) physical activity of female was higher than male. College students' high-intensity physical activity group's physical test scores were better than the medium-intensity physical activity group, and the medium-intensity physical activity group was superior to the low physical activity group. In terms of physical fitness, among the test indicators of body shape and physiological function, the vital capacity and body mass index of male and female were ranked at a pass level. In the physical fitness test indicators, the performance of college students' endurance qualities was better while the overall performance of strength qualities was lower. The overall fitness of college students was ranked at a pass level, and the physical test scores of female were better than male.

A Study on the Sensitivity of Surface Plasmon Resonance Sensor Chips with Various Material Configurations in Angle and Intensity Detection Modes (공명각 및 반사광 측정 모드에서 다양한 물질 구성의 표면 플라즈몬 공명 센서 칩의 민감도 특성)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.402-407
    • /
    • 2017
  • Characteristics of various material surface plasmon resonance (SPR) chips were investigated in angular interrogation mode and intensity interrogation mode. Among five metals, silver (Ag), gold (Au), copper (Cu), chromium (Cr) and titanium (Ti), three metals, Ag, Au and Cu were paid attention to since their characteristics can be easily analyzed in angular interrogation mode by investigating the change of their reflectance curves according to refractive index change from 1.331 to 1.335. Most of SPR chips with various configurations showed the similar property in angular interrogation mode. The application of the SPR chip made of Ag, Au and Cu or their combinations depends on their reflectance properties. In intensity interrogation mode, the operation range may be limited since the variation of the intensity was not linearly related to refractive index change ranging from 1.331 to 1.335. However, the SPR chip containing high ratio of Ag may be applicable to high sensitive detection due to their sharp reflectance curves in intensity interrogation mode.

Evaluation of Floc Formation Conditions for Increasing Flotation Velocity in DAF Process (DAF 공정에서 부상속도 향상을 위한 플럭형성 조건 평가)

  • Kwon, Soon-Buhm;Min, Jin-Hee;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.245-255
    • /
    • 2006
  • Dissolved air flotation is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In order to enhance the flotation velocity and removal efficiency of flocs in the flotation process, we tried to obtain pretreatment conditions for the optimum DAF process operation by comparing and evaluating features of actual floc formation and flotation velocity etc, according to coagulant types and conditions for flocculation mixing intensity by using PIA, PDA, and FSA. Accordingly, generating big flocs that have low density at low flocculation mixing intensity may reduce treatment efficiency. In addition, generating small flocs at high flocculation mixing intensity makes floc-bubbles smaller, which reduces flotation velocity, In this study, it was found that high flocculation mixing intensity could not remove the remaining micro-particles after flocculation, which had negative effects on treated water quality, Therefore, in order to enhance treatment efficiency in a flotation process, flocculation mixing intensity around $50sec^{-1}$ is effective.

Growth Responses and Introduction Plan of Interior Landscape Plants under Light Intensity of Fluorescent Light and Sunlight (형광등과 자연광의 광도에 따른 실내조경식물의 생육반응과 도입 방안)

  • Choi Kyoung-Ok;Lee Sang-Woo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.119-128
    • /
    • 2005
  • This study was carried out to obtain fundamental information of growth response of interior landscape plants under a fluorescent lighting, a sunlight at indoor. Ficus elastica Roxb. vu. decora Hort, Spathiphyllum 'Clevelandii', Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' and Cordyline terminalis Kunth var. red edge Hort were examined under 100lux, 500lux, 1,000lux and 2,000lux light intensity consisted of fluorescent lighting and sunlight at indoor condition. Result of experiments are as follows; 1. A Ficus elastica Roxb. var. decora Hort plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting in cases of all conditions. 2. A Spathiphyllum 'Clevelandii' showed the best effective adaptations under law intensity among experimental plants. A Spathiphyllum 'Clevelandii', plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 1,000lux light intensity of fluorescent lighting in cases of all conditions. 3. It need the best high establishment of fluorescent lighting among experimental plants for good plant growth. A Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status was better showed under high light intensity in case of same light source. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting. 4. A Cordyline terminalis Kunth var. red edge Hort plant growth status was better showed under fluorescent lighting than sunlight. but, A plant growth status was better showed under $500lux\sim1,000lux$ than 2,000lux in cases of all intensity of fluorescent lighting. while, A plant growth status was better showed under $1,000lux\sim2,000lux$ in cases of all intensity of sunlight.

Effect of High Temperature and Growth Light Intensity on Fatty Acid Composition of Panax ginseng leaf (고온(高溫)과 재배광도(栽培光度)가 인삼(人蔘) 잎의 지방산(脂肪酸) 조성(組成)에 미치는 영향(影響))

  • Park, Hoon;Park, Hyeon-Suk;Hong, Jong-Uck
    • Applied Biological Chemistry
    • /
    • v.29 no.4
    • /
    • pp.366-371
    • /
    • 1986
  • Fatty acid compositions of Panax ginseng leaves (6 year) grown under different light intensity in field and of the detached leaves exposed to high temperature (20 hours) were investigated by gas chromatography. Linoleic, linolenic, palmitic and palmitoleic acid were the major components(80%) of leaf lipid. The higher the growth light intensity, the lower the percentage of unsaturated acids or bonds, indicating metabolic adaptation to high temperature. Pattern similarity of fatty acid composition was little changed until 20% light but significantly different at 30%, suggesting 20% as limitation light intensity. The close similarity of fatty acid composition between the loaves grown under 30% light and the one at harvest rises uncertainty between adaptation to high temperature and senescence. Total fatty acid content decreased with the increase of light intensity. Short term high temperature $(25^{\circ}C\;or\;35^{\circ}C)$ increased total fatty acid content, unsaturated acid percentage and insignificant difference in pattern similarity of composition.

  • PDF