• 제목/요약/키워드: High Gauge

검색결과 450건 처리시간 0.024초

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구 (CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS)

  • 송병철;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제32권1호
    • /
    • pp.37-46
    • /
    • 2007
  • C-shape 근관은 주로 하악 제 2대구치에서 보이는 해부학적 변이 형태로서, 그 특징은 각 근관을 연결하는 fin이나 web이 존재한다. 이런 해부학적으로 복잡함은 근관치료시에 세정과 성형 및 근관충전을 방해하며, 과다한 기구 조작시에 뜻하지 않는 천공을 유발하기도 한다. 이 연구의 목적은 C-shape 치근을 가진 하악 제2 대구치의 해부학적인 형태와 치근의 위치에 따른 최소 근관벽 두께에 대하여 연구하고자 하였다. 발거된 하악 대구치중 C-shape 치근을 가진 치아를 30개 선별하여 방사선 사진 및 협측, 설측, 치근단 부위를 디지털 카메라를 이용하여 촬영하였다. 자가 중합형 교정용 레진 (Orthodontics resin, Densply/Caulk, U.S.A)을 이용하여 치관부를 제거한 치아를 매몰한 후 각각의 시편을 Accutom-50 (Struers, Denmark)에 고정시켜 1 mm 간격으로 절단, 연마한 다음 절단면을 수술용현미경에 연결된 디지털 카메라 (Coolpix 995, Nikon, Tokyo, Japan)를 이용하여 각각의 상을 촬영하였다. 30개 치아에서 촬영한 197개의 치아단면을 Root thickness gauge program을 이용하여 근관형태의 변화를 분류하고 부위별 근관과 치아외벽 사이에 존재하는 상아질의 최소두께에 대해 연구 분석하였다. 1. 근관입구에서 C I이 가장 많이 (73%) 관찰되었으나 치근단부로 갈수록 근관 형태의 다양한 변화를 보여 C II와 C III의 근관형태가 많이 관찰되었으며, 11 개의 (36%)치아에서는 근관입구에서 치근단부까지 근관형태의 변화를 보이지 않았다. 근관입구에서 단지 2개의 치아에서 나타난 C III type은 치근단부로 갈수록 높은 발현빈도를 나타내었다. 2. C-shape 근관은 근관입구 부위에서는 continuous 나 semicolon canal을 가지나 치근단부로 갈수록 2개나 3개의 근관을 갖는 경우가 많다. 3.평균적인 근관과 치질사이의 최소거리는 근첨부의 설측부위에서 나타났다.

C-factor와 충전법이 복합레진의 중합 수축에 의한 치질에서의 수축 응력에 미치는 영향 (EFFECT OF C-FACTOR AND LAYERING TECHNIQUE ON THE CONTRACTION FORCE OF COMPOSITE RESIN RESTORATION TO TOOTH SURFACE)

  • 이봉규;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제33권2호
    • /
    • pp.233-243
    • /
    • 2006
  • 와동 형성시 C-factor와 충전방법이 복합레진 수복물에서의 수축 응력에 미치는 영향을 평가하고자 발거된 소구치를 대상으로 C-factor가 3.6과 1.0인 와동을 각각 형성한 후 hybrid형 복합레진인 $Z-250^{TM}$(3M ESPE U.S.A.)과 flowable형 복합레진인 $Filtek\;flow^{TM}$(3M ESPE U.S.A.)를 사용하여 layering을 시행하고 광중합하면서 strain gauge법을 이용하여 치질에서의 수축 응력을 측정하였다. 시편을 절단하여 레진과 상아질 사이 계면의 접착상태를 주사전자현미경으로 관찰한 결과 다음과 같은 결과를 얻었다. 1. C-factor에 따른 수축 응력을 측정한 결과 C-factor가 3.7인 제 1군과 제 2군 그리고 제 5군이 900초 후 각각 0.11, 0.07, 0.07 MPa로 C-factor가 1.0인 제 3군과 제 4군의 0.05와 0.04 MPa에 비해 크게 나타났다(P<0.05). 1,800초 후에는 제 1군, 제 5군, 제 2군, 제 3군, 제 4순으로 크게 나타났으나 제 2군과 제 3군 그리고 제 3군과 제 4군 사이에는 유의성이 없었다. 2. 재료에 따른 수축 응력의 차이는 C-factor가 3.7인 와동의 경우 hybrid형 레진인 Filtek $Z-250^{TM}$이 flowable 레진인 $Filtek\;flow^{TM}$에 비해 수축 응력이 크게 나타났으나(P<0.05), C-factor가 1.0인 와동의 경우 재료의 차이에 따른 수축응력의 유의한 차이가 없었다. 3. Layering에 따른 수축 응력은 Filtek $Z-250^{TM}$을 layering 없이 bulk 충전한 제 1군에 비해 flowable 레진을 layering한 제 5군이 전 측정 시간대에 걸쳐 수축 응력이 유의하게 낮게 나타났다(P<0.05). 4. C-factor가 3.7인 제 1군과 제 2군 제 5군은 900초까지 수축 응력이 증가하다 이후 점차 감소하는 경향을 보였다. 5. C-factor가 1.0인 와동의 경우 충전용 레진 종류에 관계없이 레진과 와동벽 사이에 긴밀한 접착 상태를 보였으나 C-factor가 3.7인 와동의 경우 부분적으로 틈이 관찰되었다. 전반적으로 와동저에 비해 와동벽에서 틈이 더 많이 관찰되었다. 이상의 결과를 종합하여 보면 복합레진 수복시 수축응력에 따른 합병증을 예방하기 위해 C-factor를 크지 않게 와동을 설계, 형성하여야 하며 C-factor가 클 경우 flowable 레진을 이장하는 등 재료적인 면에서의 선택과 적용법이 중요할 것으로 사료된다.

  • PDF

고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계 (Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository)

  • 황현중;박창희;홍창호;김진섭;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.451-464
    • /
    • 2022
  • 고준위방사성폐기물 처분장은 심지층 처분시스템으로 사용후핵연료를 취급하는 특성상 고온, 방사선 및 지하수 등의 복합적인 환경조건에 노출되어 있다. 지속적인 노출에 의해 시간이 지남에 따라 구조물의 균열 및 열화가 발생할 수 있다. 한편 고준위방사성폐기물 처분장은 초장기 기대수명이 요구되며 이에 따른 장기적인 구조물 건전성 모니터링이 필수적이다. 구조물 건전성 모니터링에는 가속도계, 토압계, 변위계 등 다양한 센서들이 활용될 수 있으며, 이 중 일반적으로 피에조센서가 사용된다. 따라서 피에조센서의 내구성 평가를 바탕으로 고내구성 센서를 개발할 필요가 있다. 본 연구에서는 피에조센서의 내구성 평가 및 수명예측을 위한 가속수명시험을 설계하였다. 문헌연구를 바탕으로 단일 스트레스 인자에 대한 가속 스트레스 수준 수 및 각 수준 별 시료 수를 선정하였다. 또한 고준위방사성폐기물 처분장 환경조건에서 발생할 수 있는 피에조센서의 고장모드 및 고장메커니즘을 분석하였다. 온도 스트레스 인자에 대한 최대 가혹조건 탐색 실험을 두 가지 방법으로 제안하였으며 피에조센서의 신뢰도 높은 동작한계를 도출하였다. 이를 이용하여 가속수명시험의 합리적인 가속 스트레스 수준을 설정하였다. 본 연구에서 제시된 최대 가혹조건 탐색 실험방법은 경제적이며 실용적인 아이디어를 담고 있으며, 추후 피에조센서의 가속수명시험 설계에 널리 활용될 수 있을 것으로 판단된다.

골수공여자들의 불편감 (Discomfort of Donors associated with Bone Marrow Donation)

  • 유하정;박선남;문정순
    • 한국보건간호학회지
    • /
    • 제15권1호
    • /
    • pp.157-171
    • /
    • 2001
  • The study was designed to provide the fundamental information for understanding discomfort of bone marrow donors and for promoting an individual comfort by comparing the difference on discomfort between unrelated donors and related donors. The subject of the study was fifty related donors and thirty unrelated donors who was in the C University Hospital. This survey had been carried out and collected from October, 1998 to March, 1999. The scale of discomfort of donors associated with bone marrow donation were assessed by the questionnaire deviced by Kim Sang Dol and amended by the researcher. Data was analyzed by $x^2-test$, t-test, two-way ANOVA, and Pearson Correlation Coefficients. The results were as follows. 1. Considering the general characteristics of bone marrow donors according to gender, male was consisted of $60\%$ and female was consisted of $40\%$. Of those related donors are consisted for $62.5\%$ and accounted for $37.5\%$ of those unrelated donors. Considering the classification to the job, employee of company were major donors which was $35\%$, and next order was student, individual businessman, and housewife. Considering the education level. college students were $48.7\%$ and students who have less than high school level were $42.5\%$. 2. According to the above the results regarding discomfort of bone marrow donation, it is especially shown that the major cause for discomfort of bone marrow donors is on physical factor. The concrete examples for physical factor are pain in the region of bone marrow harvest and pain in the injection part by fluid therapy and blood-sampling, an immovability of the body after bone marrow harvest, and difficulties on walking. Considering physiological factor, there are an uneasiness about leading to injure their health, vague fear about the hospital. and a tedium at hospital. Environmental factors for discomfort of bone marrow donors are insufficient explanation for needle gauge and procedure of bone marrow donation and difficulty on following medical schedule. Therefore. it is necessary to establish more effective and systematically organized program for nursing intervention based on the research results. An effective program is only useful in getting rid of discomfort of bone marrow donors.

  • PDF

나일론과 천연섬유 복합소재의 염색 시 알칼리에 따른 영향 연구 (Alkalic Effects on Dyeing of Nylon, Rayon, Wool blended Fabrics)

  • 김지연;강숙희;민문홍;김문정;이동은;김병열
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2012년도 제46차 학술발표회
    • /
    • pp.107-107
    • /
    • 2012
  • 3종 복합소재인 양모와 나일론, 레이온의 염색공정은 먼저 알칼리 욕에서 반응성염료로 레이온을 염색한 후, 산성욕에서 산성염료로 양모와 나일론을 염색하는 것이 일반적이다. 그런데 양모, 나일론, 레이온은 알칼리에 민감하므로 면 염색 시 적용되는 강알칼리인 수산화나트륨을 사용하면 섬유의 취화로 인하여 강도와 촉감저하 등의 문제가 발생하게 된다. 따라서 본 연구에서는 알칼리 중 탄산나트륨과 중탄산나트륨을 사용하여 염료를 투입하지 않고 염색공정을 거친 후 백도와 인장강도를 측정하여 황변 및 강도 변화 여부를 알아보았다. 레이온 70%, 양모 19%, 나일론 11%의 혼용율을 가지는 전처리 된 편물(130$g/m^2$, 32 inch, 18 gauge)에 탄산나트륨(시약 1급) 20g/l과 중탄산나트륨(시약 1급) 20g/l 각각을 투입하고 반응성염색공정($60^{\circ}C$, 60 min)으로 처리한 경우와 반응성 염색 후 산성염색공정($98^{\circ}C$, 60 min)으로 처리한 경우로 나누어 측색을 통해 백도와 L, a, b값을 측정하고 KS K 0521에 따라 인장강도 시험을 실시하였다. 그 결과, 탄산나트륨 투입시 백도 값이 중탄산나트륨에 비해 10% 정도 낮아지고 L, a, b값도 상대적으로 yellow 방향으로 이동해 있는 것으로 나타났다. 이것은 황변이 일어남을 의미하며 육안으로 확인하였다. 또한 인장강도 측정결과를 통해 소다회 처리 시 중조에 비해 30% 정도의 강도 저하가 일어남을 확인할 수 있었다. 그러나 반응성염색 후 산성염색을 거치게 되면 황변과 강도 저하 현상이 회복되는 경향을 나타내었다. 즉, 천연/나일론 편물을 반응성염색 시 알칼리로 탄산나트륨을 사용하면 염색공정 상에서 중탄산나트륨에 비해 황변이 일어나 염료 고유의 색상 발현에 영향을 줄 수 있고 강도 또한 30% 정도 저하되지만, 후에 산성염색 공정을 거치면 산 조건과 욕중 효과를 통해 일부 개선됨을 확인하였다. 이와 별도로 이번에는 시판되는 반응성염료 5종과 산성염료 3종을 조합하여 탄산나트륨과 중탄산나트륨 투입에 따른 염색실험을 실시하고 측색(DataColor SF600 광원D65, Strength)을 통해 염착량을 비교하였다. 그 결과, 중탄산나트륨으로 염색하면 탄산나트륨에 비해 모두 염착량이 저하되었으며, 염료의 구조적 차이와 컬러별로도 그 차이는 다양하였다. 그 중 저온에너지형 반응성염료는 탄산나트륨 투입에 비해 47~60% 정도로 가장 양호하였으며, 일부 반응성염료는 20%까지 떨어지는 값을 나타내었다. 이것은 탄산나트륨보다 중탄산나트륨의 알칼리 정도가 낮으므로 반응성염료의 염착이 적은 것으로 생각되며, 저에너지형 반응성염료의 경우에는 낮은 온도나 알칼리 조건에서도 상대적으로 높은 고착률을 나타내므로 적절한 반응성염료의 선택을 통해 그 차이를 극복할 수 있을 것으로 사료된다. 이상의 결과를 통해 탄산나트륨과 중탄산트륨의 알칼리 정도가 강도와 염착량에 미치는 영향의 차이를 고려하여 최적의 현장 처방을 선정해야 함을 알 수 있었다.

  • PDF

학술지 영향력 측정을 위한 h-지수의 응용에 관한 연구 (A Study on Journal Impact Measurement with Hirsch-type Indices)

  • 김판준;이재윤
    • 정보관리학회지
    • /
    • 제27권1호
    • /
    • pp.269-287
    • /
    • 2010
  • 최근까지 학술지의 영향력을 측정하기 위하여 Thomson Reuters(ISI)의 영향력지수(JIF: Journal Impact Factor)가 널리 사용되어왔다. 그러나, 이러한 JIF는 학술지 단위가 아니라 수록 논문의 평균 영향력을 측정하는 지표라는 근본적인 한계를 가지고 있으며, 이외에도 다양한 측면에서 많은 문제점들이 지적되었다. 특히 국내 인용색인은 국제적인 인용색인 데이터베이스에 비해서 인용 데이터의 규모가 상당히 제한적이므로, 이를 고려하여 국내 학술지 인용 환경에 적합한 지수의 적용이 필요하다. 따라서 이 연구는 최근 급속히 확산되고 있는 Hirsch 유형 지수(h-type indices)를 적용하여 국내 학술지의 영향력을 보다 더 상세하게 측정할 수 있는 실제적인 방안을 모색하였다. 결과적으로, h-지수의 변형지수($h_s$-지수, $f_s$-지수)를 사용하거나 호 단위 합산(호 기반 h-지수, 호 기반 f-지수) 방법을 통하여, 기존 Hirsch 유형 지수들의 변별력을 향상시킬 수 있음은 물론 국내 학술지의 영향력을 더욱 정밀하게 측정할 수 있는 것으로 나타났다.

낙동강 중류수계에서 의약물질의 분포특성 (Characteristics of Occurrence of Pharmaceuticals in the Nakdong River)

  • 이순화;정현욱;정진영;민혜주;김보람;박찬갑;오정은;오노 우;사토 노부유키
    • 대한환경공학회지
    • /
    • 제35권1호
    • /
    • pp.45-56
    • /
    • 2013
  • 본 연구는 낙동강수계의 잔류의약물질을 관리하기 위한 기초자료로 제시되었다. 낙동강 본류에서 Iopromide는 $0.0015{\sim}0.37{\mu}g/L$, Mefenamic acid은 $0.0087{\sim}0.056{\mu}g/L$, Diclofenac은 $N.D.{\sim}0.01{\mu}g/L$, Atenolol은 $N.D.{\sim}0.024{\mu}g/L$, Propranolol은 $N.D.{\sim}0.0038{\mu}g/L$, Lincomycin은 $0.0005{\sim}0.038{\mu}g/L$, Trimethoprim은 $N.D.{\sim}0.0083{\mu}g/L$의 농도범위로 검출되었다. 유역의 하수처리장에서는 대부분 고농도로 검출되었으며, 특히 Iopromide가 최고 $5.38{\mu}g/L$까지 검출되었다. 축산폐수처리장에서는 린코마이신이 최고 $477{\mu}g/L$로 가장 높게 검출되었다. 조사결과, 낙동강 본류에서 의약물질은 구미하수처리장과 대구 금호강의 유입으로 농도가 높아져 인구 산업밀집지역의 영향이 큰 것으로 판단된다. 따라서 낙동강의 잔류의약물질을 효율적으로 관리하기 위해서는 금호강과 하 폐수처리장을 지속적으로 모니터링하고 관리하는 것이 바람직한 것으로 사료된다.

THE ROLE OF SATELLITE REMOTE SENSING TO DETECT AND ASSESS THE DAMAGE OF TSUNAMI DISASTER

  • Siripong, Absornsuda
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.827-830
    • /
    • 2006
  • The tsunami from the megathrust earthquake magnitude 9.3 on 26 December 2004 is the largest tsunami the world has known in over forty years. This tsunami destructively attacked 13 countries around Indian Ocean with at least 230,000 fatalities, displaced people 2,089,883 and 1.5 million people who lost their livelihoods. The ratio of women and children killed to men is 3 to 1. The total damage costs US$ 10.73 billion and rebuilding costs US$ 10.375 billion. The tsunami's death toll could have been drastically reduced, if the warning was disseminated quickly and effectively to the coastal dwellers along the Indian Ocean rim. With a warning system in Indian Ocean similar to that operating in the Pacific Ocean since 1965, it would have been possible to warn, evacuate and save countless lives. The best tribute we can pay to all who perished or suffered in this disaster is to heed its powerful lessons. UNESCO/IOC have put their tremendous effort on better disaster preparedness, functional early warning systems and realistic arrangements to cope with tsunami disaster. They organized ICG/IOTWS (Indian Ocean Tsunami Warning System) and the third of this meeting is held in Bali, Indonesia during $31^{st}$ July to $4^{th}$ August 2006. A US$ 53 million interim warning system using tidal gauges and undersea sensors is nearing completion in the Indian Ocean with the assistance from IOC. The tsunami warning depends strictly on an early detection of a tsunami (wave) perturbation in the ocean itself. It does not and cannot depend on seismological information alone. In the case of 26 December 2004 tsunami when the NOAA/PMEL DART (Deep-ocean Assessment and Reporting of Tsunami) system has not been deployed, the initialized input of sea surface perturbation for the MOST (Method Of Splitting Tsunami) model was from the tsunamigenic-earthquake source model. It is the first time that the satellite altimeters can detect the signal of tsunami wave in the Bay of Bengal and was used to validate the output from the MOST model in the deep ocean. In the case of Thailand, the inundation part of the MOST model was run from Sumatra 2004 for inundation mapping purposes. The medium and high resolution satellite data were used to assess the degree of the damage from Indian Ocean tsunami of 2004 with NDVI classification at 6 provinces on the Andaman seacoast of Thailand. With the tide-gauge station data, run-up surveys, bathymetry and coastal topography data and land-use classification from satellite imageries, we can use these information for coastal zone management on evacuation plan and construction code.

  • PDF

3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석 (Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses)

  • 김상범;이두형;이청희
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.321-327
    • /
    • 2020
  • 목적: 본 연구의 목적은 3본 나사 유지형 임플란트 보철물의 나사 고정 방식에 따른 치경부에 발생하는 변형율을 측정하고 비교하기 위함이다. 재료 및 방법: 2가지 종류의 임플란트(외부연결방식, 내부연결방식)를 각각 2개씩 4개 임플란트 고정체 경부에 스트레인 게이지를 부착한 후, 각 종류의 아크릴릭 레진 모형 2개를 제작하였다. CAD-CAM을 이용하여 hex 및 nonhex 지대주를 제작하였고,(EH, ENH, IH& INH 군) 나사-시멘트 유지보철 개념으로 보철물을 비귀금속으로 제작하였다. 각 지대주를 10 Ncm 토크로 고정한 후, 보철물을 합착하였다. 나사를 3가지의 다른 방법으로 30 Ncm까지 고정한 다음, 5분 후 변형율을 측정한 후 평균비교 및 군간 상호작용을 평가하였다 (α = .05). 결과: 외부연결방식 군은 내부연결방식 군에 비하여 유의하게 낮은 변형율을 나타냈으며, EH군이 ENH군보다 유의하게 낮은 변형율을 나타내었으나 (P < .05), 나사 고정 방법에 따른 차이는 없었다 (P > .05). IH군이 INH군에 비하여 유의하게 높은 변형율을 나타내었으며 IH군에서만 나사 고정 방법에 따라서도 차이가 있었다 (P < .05). 결론: 나사 유지형 임플란트 보철물에서는 외부연결방식인 경우에는 큰 영향이 없으나, 내부연결방식에서는 보다 큰 변형율이 발생하고 나사 고정 방법도 영향을 주는 것으로 나타났다.