• 제목/요약/키워드: High Flow Rate

검색결과 3,270건 처리시간 0.032초

전기히터방식 매연여과장치의 PM 산화 특성에 관한 연구 (A Study on the PM Oxidation Characteristics of Electrical Heater DPF System)

  • 함윤영;김대하;김경운
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.183-190
    • /
    • 2006
  • For continuously regenerative PM collecting system which adopted thermally stable SiC DPF and electrical heater which was placed upstream of the filter and driven by well constructed control logic, PM oxidation characteristics were investigated varying air flow rate, amounts of PM accumulated on the DPF and filter inlet temperature in order to get optimized PM regeneration performance. This study showed that the operating condition of air flow rate 70 lpm, high PM loading around 30g and filter inlet temperature $700^{\circ}C$ with heat insulation was effective in achieving high regeneration efficiency. Also, in this condition, we could decrease the electric energy consumption by reducing the regeneration time.

A comparing on the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle

  • Thawichsri, Kosart;nilnont, Wanich
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.58-66
    • /
    • 2015
  • This paper aims to compare the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle (ORC) Machine using Isopentane as working fluid expanding. The working fluid has boiling point below boiling water and works in low-temperature sources between $80-120^{\circ}C$ which can be produced from waste heat, solar-thermal energy and geothermal energy etc. The experiment on ORC machine reveals that the suitability of high pressure pump for working fluid has result on the efficiency of work. In addition, Thermodynamics theory on P-h diagram also presented the effect of heat sources' temperature and flow rate on any work. Thus, the study and design on ORC machine has to concern mainly on pressure pump, flow rate and optimized temperature. Result experiment and calculate ORC Machine using centrifugal Turbine efficiency better than Tesla turbine 30% but Tesla Turbine is cheaper and easily structure. Further study on the machine can be developed throughout the county due to its low cost and efficiency.

글로벌 모델에 의한 저온 고밀도 플루오로카본 플라즈마 특성의 공정변수 의존성 해석 (Analysis of Process Parameter dependency on the characteristics of high density fluoro carbon plasma using global model)

  • 이호준;태흥식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.879-881
    • /
    • 1999
  • Radical and ion densities in a CF4 plasma have been calculated as a function of input power density. 9as pressure and feed gas flow rate using simple 0 dimensional global model. Fluorine atom is found to be the most abundant neutral particle. Highly fragmented species such as CF and CF+ become dominant neutral and ionic radical at the high power condition. As the pressure increases. ion density increases but ionization rate decreases due to the decrease in electron temperature. The fractional dissociation of CF4 feed gas decreases with pressure after increasing at the low pressure range. Electron density and temperature are almost independent of flow rate within calculation conditions studied. The fractional dissociation of CF4 monotonically decreases with flow rate. which results in increase in CF3 and decrease in CF density. The calculation results show that the SiO2 etch selectivity improvement correlates to the increase in the relative density of fluorocarbon ion and neutral radicals which has high C/F ratio.

  • PDF

단위전류당 고유량 유기용매 이송을 위한 다공성 실리콘막 전기침투 펌프의 개발 (Development of Porous Silicon Electro-osmotic Pumps for High Flow Rate Per Current Flow Delivery of Organic Solvents)

  • 권길성;김대중
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.105-111
    • /
    • 2010
  • 양극산화법과 DRIE 법으로 제작된 다공성 실리콘막을 이용하여 두 종류의 전기침투 펌프를 제작하였다. 펌프의 성능은 유기용매를 이용하여 유량과 단위전류당 유량으로 측정하였다. 두 종류 펌프 모두 기존의 다공성 유리막으로 제작된 전기침투 펌프보다 성능이 우월했다. 특히 DRIE 법으로 제작된 다공성 실리콘막은 유량과 단위전류당 유량이 모두 월등한 성능을 보였다. DRIE 법은 널리 알려진 방법이기에 이와 같이 제작된 펌프는 다양한 응용 분야에 비교적 쉽게 적용될 것으로 기대된다.

동력조향용 압력평형형 베인펌프의 유량맥동 계측 (Measurement of Flow Ripple Generated by Balanced Vane Pumps in Automotive Power Steering Systems)

  • 김도태;김진
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.70-78
    • /
    • 2000
  • A balanced vane pump for the use of automotive power steering systems generates a flow ripple which is imposed upon the mean flow rate. The flow ripple interacts with the characteristics of the connected pipes, valves and steering gear in a complex manner to produce a pressure ripple, also known as fluid-borne noise. In order to reduce vibration level and produce quieter and more reliable power steering systems, it is important to measure the flow ripple produced by a pump with high accuracy and fast response. In this paper, the flow ripple generated by a vane pump in automotive power steering systems is measured by the remote instantaneous flow rate measurement method (RIFM) using hydraulic pipeline dynamics. In experiment, flow and pressure ripple wave forms are measured under various operating conditions. Also, the parameters affected upon the flow and pressure ripple are investigated by the frequency analysis.

  • PDF

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

LNG 터미널 유량 보정 방법 개발 (Development of LNG Terminal Flow Rate Data Reconciliation Method)

  • 이상호;이철진;임영섭;박찬샘;한종훈
    • 한국가스학회지
    • /
    • 제14권6호
    • /
    • pp.21-26
    • /
    • 2010
  • 국내의 LNG 터미널은 일반적으로 대형화 되어있다. 그런데 이런 대형화된 터미널의 안전한 관리를 위해서는 전 시설에 대한 온도 관측이 필요하며 따라서 터미널 내 모든 시설에는 온도센서가 다수 존재한다. 하지만 터미널의 운영, 관리 및 안전사고 예방을 위해서 또 파악해야 하는 정보 중 하나가 유량인데 보통 부족한 경우가 많다. 그런데 배관의 온도 정보는 유량과 밀접한 관련을 맺고 있고 이를 통해 유량은 몇 가지 가정을 통해서 쉽게 추산할 수 있다. 이렇게 발생된 유량 데이터는 오차를 갖고 있을 수 있기 때문에 이를 정상상태 데이터 보정(steady state data reconciliation)을 활용하면 보다 신뢰성 있는 데이터를 얻을 수 있다. 본 논문에서는 이러한 LNG 터미널 데이터 보정 방법에 대해 설명하고 사례연구를 통해 얼마나 신뢰성 있는 데이터를 제공하는지에 대해서 기술하고자 한다.

플러그 밸브의 포트형상 변화에 따른 유동특성 연구 (A study on the flow characteristics in a plug valve with various port shapes)

  • 최근우;박권종;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.259-264
    • /
    • 2000
  • The functions of the plug valve are the control of flow rate as well closing and opening pipe lines. Analyses on the flow characteristics in plug valve port are required to improve the performance and safety at severe operating conditions such as high-pressure and high-temperature. In this study, numerical analyses are carried out with varying the opening rate (fraction of the full open to close) of the valve and the shapes of valve Uk: straight, convex, concave and mixed shapes. The parameters influencing the flow characteristics in the valve are the discharge coefficient( $C_v$) and the resistance coefficient( K). Therefore, the distributions of static pressure, velocity vector and stream lines are investigated, and $C_v$ and K are calculated in each opening rate and shape. In case of full open, the static pressure passed through the valve port has almost been recovered. However, in case of other opening rates, the pressure does not permanently regained due to pressure drop leading to loss. This phenomenon in each shape of the valve shows the different behaviors. Calculation results show that the mixed shape has the best flow attribute.

  • PDF

보조동력장치 회전자 유동 및 출력특성에 관한 연구 (A Study on the Flow and Power Characteristics of Rotor in the APU)

  • 이중섭;정인국;윤지훈;서정세;이태의
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.805-810
    • /
    • 2011
  • Recently, Use of Auxiliary power unit(APU) is increasing by growing demand for improvement of insufficient electric power and installation of emergency generation devices in military tracked vehicles and civil markets. And the trend is that the units are demanded for smaller size, lighter weight and higher output power, etc to suit consumer demands. To achieve these, it is essential to develop high performance system. Therefore, in this study, it was conducted in numerical analysis to investigate flow characteristics of rotor in APU generator. Also output performance of APU applied on the rotor is analyzed by experimental method. As the result, higher rotating speed of rotor caused high air flow rate at suction and it leads to linear increase of discharging flow rate. The maximum theoretical power was achieved at 12 $m^3$/min of flow rate and, at that time, output power of generator was about 7.825 kW. Also, it can be confirmed the stabilization of output performance is achieved in about 2 seconds by experiment.

Effect of Partial Flow Reductions on DNAPL Source Dissolution Rate

  • Park, Eung-Yu;ParKer, Jeck C.
    • 대한자원환경지질학회:학술대회논문집
    • /
    • 대한자원환경지질학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.148-151
    • /
    • 2005
  • Field-scale DNAPL dissolution is controlled by the topology of DNAPL distributions with respect to the velocity field. A high resolution percolation model was developed and employed to simulate the distribution of DNAPL within source zones. Statistically anisotropic permeability values and capillary parameters were generated for 10${\times}$10${\times}$10 m domains at a resolution of 0.05 to 0.1 m for various statistical properties. TCE leakage was simulated at various rates and the distribution of residual DNAPL in 'fingers' and 'lenses' was computed. Variations in finger and lens geometries, frequencies, average DNAPL saturations, and overall source topology were predicted to be strongly influenced by statistical properties of the medium as well as by injection rate and fluid properties. Model results were found to be consistent with observations from controlled DNAPL release experiments reported in the literature. The computed distributions of aquifer properties and DNAPL were utilized to perform high-resolution numerical simulations of groundwater flow and dissolved transport. Simulations were performed to assess the effect of grout or foam injection in bore holes within the source zone and of shallow point-releases of fluids with various properties on dissolution in DNAPL dissolution rate, even for widely spaced injection points. The results indicate that measures that induced partial flow reductions through DNAPL source zones can significantly decrease dissolution rates from residual DNAPL. The benefit from induced partial flow reductions is two-fold: 1) local flow reduction in DNAPL contaminated zones reduces mass transfer rates, and 2) contaminant flux reductions occur due to the decrease in groundwater velocity

  • PDF