• 제목/요약/키워드: High Exposure Contact Work

검색결과 21건 처리시간 0.025초

Occupational Dermatoses by Type of Work in Greece

  • Zorba, Eleni;Karpouzis, Antony;Zorbas, Alexandros;Bazas, Theodore;Zorbas, Sam;Alexopoulos, Elias;Zorbas, Ilias;Kouskoukis, Konstantinos;Konstandinidis, Theodoros
    • Safety and Health at Work
    • /
    • 제4권3호
    • /
    • pp.142-148
    • /
    • 2013
  • Background: To elucidate the relationship between seven occupational dermatoses (ODs) and 20 types of work in Greece. Methods: This was a prevalence epidemiologic study of certain ODs among 4,000 workers employed in 20 types of enterprise, in 104 companies, in 2006-2012, using data from company medical records, questionnaires, occupational medical, and special examinations. The ${\chi}^2$ test was applied to reveal statistically significant relationships between types of enterprises and occurrence of ODs. Results: A high percentage (39.9%) of employees included in the study population suffered from ODs. The highest prevalence rates were noted among hairdressers (of contact dermatitis: 30%), cooks (of contact dermatitis: 29.5%), bitumen workers (of acne: 23.5%), car industry workers (of mechanical injury: 15%), construction workers (of contact urticaria: 29.5%), industrial cleaning workers (of chemical burns: 13%), and farmers (of malignant tumors: 5.5%).We observed several statistical significant correlations between ODs (acute and chronic contact dermatitis, urticaria, mechanical injury, acne, burns, skin cancer) and certain types of enterprises. There was no statistically significant correlation between gender and prevalence of ODs, except for dermatoses caused by mechanical injuries afflicting mainly men [${\chi}^2(1)=13.40$, p < 0.001] and for chronic contact dermatitis [${\chi}^2(1)=5.53$, p=0.019] afflicting mainly women. Conclusion: Prevalence of ODs is high in Greece, contrary to all official reports by the Greek National Institute of Health. There is a need to introduce a nationwide voluntary surveillance system for reporting ODs and to enhance skin protection measures at work.

일반제재업의 작업장소별 위험성 평가 (A study on the risk assessment of the workplaces in the General Sawmill Industry)

  • 이홍석;신운철
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.105-112
    • /
    • 2015
  • Sawmilling industry remained a high risk with the average 4.73% of industrial accidents in 2010-2012 that was eight times that of general manufacturing. Sawmilling industry had 200 industrial accidents victim in average. Manufacturing process in sawmill industry contained dangerous machinery such as conveyors, roller, saw ( band saw, circular saw) etc. It may be effective to figure out the type of industrial accidents occurred in the past and extend risk assessment which can predict hazard such as near miss when implementing exposure or potential dangers in sawmill industry. This study conducted research on the actual condition on the place of industrial accident occurrence, detailed work and contact object when injured, and injured part targeting 643 businesses which had industrial accidents in 2010-2012. As the results, RPN of general sawmill industry was the highest 'ganglip saw' with 36,157. RPN of the following order were 'moving truck' with 25,454, 'special machining operations' with 22,283. Also, probability of general sawmill industry was a lots within 1 year, while risk appeared a lots within 5 years. So, risk assessment shall be needed to emphasis on accident prevention of sawmill industry. And additional work will be needed on the risk assessment in hazard prevention work of supervisors.

자기 흡인식 부상 원리에 기초한 비접촉식 서피스 액추에이터의 초정밀 범용 스테이지에의 적용 가능성 (Feasibility Study of General-purpose Precision Stage Using A Novel Contact-Free Surface Actuator Based on Magnetic Suspension Technology)

  • 정광식;이상헌;백윤수
    • 대한기계학회논문집A
    • /
    • 제26권3호
    • /
    • pp.452-460
    • /
    • 2002
  • The precision stage using a novel contact-free planar actuator based on magnetic farces, magnetized force and Lorentz farce, is suggested. In the promising magnetic structure, the mover is driven directly without any transmission mechanism, and doesn't need any auxiliary driver for its posture calibration. Then it is estimated that the proposed operating principle is very suitable for work requiring high accuracy and cleanness, or general-purpose nano-stage. In this paper, we discuss a driving principle of the planar system including the magnetic force generation mechanism, a framework for the force model, governing characteristics of the levitated plate, and a planar motion control of the constructed prototype. And experimental results are given to verify the derived theoretical model and a feasibility of the system.

Neutron irradiation of alloy N and 316L stainless steel in contact with a molten chloride salt

  • Ezell, N. Dianne Bull;Raiman, Stephen S.;Kurley, J. Matt;McDuffee, Joel
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.920-926
    • /
    • 2021
  • Capsules containing NaCl-MgCl2 salt with 316L stainless steel or alloy N samples were irradiated in the Ohio State University Research Reactor for 21 nonconsecutive hours. A custom irradiation vessel was designed for this purpose, and details on its design and construction are given. Stainless steel samples that were irradiated during exposure had less corrosive attack than samples exposed to the same conditions without irradiation. Alloy N samples showed no significant effect of irradiation. This work shows a method for conducting in-reactor irradiation-corrosion experiments in static molten salts and presents preliminary data showing that neutron irradiation may decelerate corrosion of alloys in molten chloride salts.

The Type of Payment and Working Conditions

  • Rhee, Kyung Yong;Kim, Young Sun;Cho, Yoon Ho
    • Safety and Health at Work
    • /
    • 제6권4호
    • /
    • pp.289-294
    • /
    • 2015
  • Background: The type of payment is one of the important factors that has an effect on the health of employees, as a basic working condition. In the conventional research field of occupational safety and health, only the physical, chemical, biological, and ergonomic factors are treated as the main hazardous factors. Managerial factors and basic working conditions such as working hours and the type of payment are neglected. This paper aimed to investigate the association of the type of payment and the exposure to the various hazardous factors as an heuristic study. Methods: The third Korean Working Conditions Survey (KWCS) by the Occupational Safety and Health Research Institute in 2011 was used for this study. Among the total sample of 50,032 economically active persons, 34,788 employees were considered for analysis. This study examined the relation between the three types of payment such as basic fixed salary and wage, piece rate, and extra payment for bad and dangerous working conditions and exposure to hazardous factors like vibration, noise, temperature, chemical contact, and working at very high speeds. Multivariate regression analysis was used to measure the effect of the type of payment on working hours exposed to hazards. Results: The result showed that the proportion of employees with a basic fixed salary was 94.5%, the proportion with piece rates was 38.6%, and the proportion who received extra payment for hazardous working conditions was 11.7%. Conclusion: The piece rate was associated with exposure to working with tight deadlines and stressful jobs. This study had some limitations because KWCS was a cross-sectional survey.

테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구 (A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers)

  • 최호춘;홍좌령;이귀영;김두호;박정일
    • 한국산업보건학회지
    • /
    • 제21권3호
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

도장 부서 남성 근로자들의 피부 질환 (Skin diseases of male workers in painting workplace)

  • 박재범;이경종;장재연;정호근
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.830-839
    • /
    • 1997
  • 직업성 피부 질환을 일으키는 주요 작업 공정의 하나인 도장작업자들의 피부 질환의 실태를 파악하기 위하여 모 조선업체 도장 부서의 남자 근로자 379명을 폭로군으로, 같은 회사 비도장부서에서 근무하고 유기용제를 취급한 경력이 없는 근로자 151명을 대조군으로 선정하여 피부과 전문의의 진료와 설문 조사를 통하여 아래와 같은 결과를 얻었다. 피부과적 진찰 결과 도장부서 근로자들이 이환되어 있는 가장 흔한 피부질환은 족부 백선으로 폭로군의 유병률은 48.0%였으며 대조군에 비하여 이환될 비차비가 3.18로 통계학적으로 유의한 차이를 보였다. 접촉성 피부염과 한포진의 유병률도 각각 11.9%, 11.9%로 대조군보다 유의하게 높았으며 질병에 이환될 비차비가 4.95, 6.64로 통계학적으로 유의한 차이를 보였다. 이외에도 비특이적 습진, 자극성 피부염, 모낭염, 두드러기 등과 같은 피부 질환이 관찰되었으나 대조군과 유의한 차이는 없었다. 접촉 피부염 소견을 보이는 폭로군 중 71.1%가 피부 증상이 휴일이나 휴가시에 호전된다고 응답하였고, 68.9%가 옷이나 보호구에 가려지지 않는 노출부위에 피부 병변이 발생한다고 응답하여 접촉 피부염이 작업과 관계가 있음을 시사하였다. 근로자들의 보호구 착용률은 비교적 양호한 편이었지만 보호구 착용과 피부질환과는 연관성이 없어서 보호구 착용이 피부질환의 예방에 큰 효과가 없는 것으로 나타났다. 대조군과 유의한 차이를 보인 접촉 피부염, 한포진, 족부 백선의 유병률을 수행직무별로 스프레이군, 터치업군, 혼합군, 전처리군으로 구분하여 비교한 결과 유의한 차이를 보이지 않아 피부 질환의 위험도는 수행직무에 따라서는 큰 차이가 없음을 보여주었다. 도장 부서 근무 년수에 따른 비교에서도 근무 년수가 증가함에 따라 유병률이 증가하는 소견을 보이지 않았는데 근무 기간에 길어질수록 피부 저항이 증가되며, 피부반응이 둔해지며, 숙련된 작업으로 접촉물질에 대한 노출이 감소되기 때문이라고 판단된다. 이상과 같이 조선업체 도장부서 근로자들에게서 접촉 피부염, 한포진, 족부 백선 등 작업과 연관된 질병을 발견할 수 있었다. 앞으로 도장 부서 근로자들의 피부 병변을 예방하기 위한 대책 마련이 시급하다고 생각한다.

  • PDF

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF