• Title/Summary/Keyword: High Efficiency Aeration System

Search Result 26, Processing Time 0.026 seconds

Effects of Artificial Filaments Equipped in the Aeration Tank of Aerobic Fermentation System on the Removal Efficiency of Nitrogen of Swine Wastewater Containing High Nitrogen (담체설치가 고질소함유 양돈폐수의 호기발효에 미치는 영향)

  • 손경호;이상락;안정제;권윤정;정태영
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • This study was conducted to investigate the effects of artificial filaments equipped in the aeration tank of aerobic·fermentation system on the removal efficiency of swine wastes which were fermented an aerobically and thus containing high nitrogen. Two aerobic fermentation system each consist4s of 4 tanks ; storage tank, 1st and 2nd aeration tank and settling tank were run before and one or three weeks after equipment of artificial filament in the aeration tanks. Total solids concentration tended to increase by aerobic fermentation in all running periods. However, decreased(P<0.05) total nitrogen concentration was shown three weeks after the equipment of artificial filament. Ammonia nitrogen concentration also largely decreased(p<0.05) in both running periods of one and three weeks after equipment of artificial filaments. These results suggest that the artificial filaments may improve the removal efficiency of nitrogen in swine wastewater containing high nitrogen during aerobic fermentation.

  • PDF

Reduction of Organic Sludge using High Efficiency Aeration System(HEAS) (고효율 포기 시스템을 이용한 유기성 슬러지의 감량화)

  • Oh, Sea-Bae;Lee, Sang-Houck
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.221-227
    • /
    • 2012
  • In Korea, ocean dumping has been widely used as the ultimate disposal of sewage sludge. However, ocean dumping of food wasted and sewage sludge from 2013 is expected to legally restricted as London convention on marine pollution prevention has been effective in 2009. This research aims to examine the effect of HEAS in treating the environmental pollution load caused by organic high concentrated sludge. Thus, onsite laboratory scale treatability test using HEAS was adopted to treat the high concentrated organic sludge from sewage and industrial wastewater treatment plant. The research results showed that the HEAS is useful to reduce the environmental pollution caused by organic high concentrated sludge. Specific results are as follows. 1. The organic removal after the sludge digestion using the high efficiency aeration system was 55.2-85.8%. Although these results were lower than those from the general sewage treatment, the high efficiency aeration system could be evaluated as efficient, considering the object sludge contained the industrial waster water. 2. The average removal efficiency was about 25.2%. 3. It was revealed that sludge digestion by the high efficiency aeration system could effectively contribute to the sludge treatment cost. Especially, the high efficiency aeration system is more applicable to the onsite treatment of small sewage and wastewater treatment plant that contains high solid content sludge, industrial wastewater sludge, high fixed solid sludge.

Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System (자화-생물처리 시스템에 의한 염색폐수의 처리)

  • Lee, Seon-Ha
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.371-377
    • /
    • 2010
  • The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In ease of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/${\ell}$ and the latter was 19.4mg/${\ell}$, theretore biological treatment efficiency identified to increase by the MWS.

Evaluation for the simultaneous Removal of Organic Matters and Nutrients by the RBC and tapered Aeration Processes with Bacillus sp. for the high Strength of Dairy Wastewater (바실러스 미생물을 이용한 고농도 유가공 폐수처리에 있어서 유기물질과 영양염류의 동시제거에 대한 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.195-202
    • /
    • 2010
  • The evaluation of organic matters and nutrients removal was investigated for the synthetic wastewater and the high strength of dairy wastewater. Two different systems were performed for this research. System A composing of a single RBC with tapered aeration was fed with the synthetic wastewater for 74 days with 173L/day of influent, 200% of internal return and 100% of sludge return for the period 1 and 2. The feed conditions were maintained 346L/day of influent, 50% of internal return and sludge return for the period 3. The dairy wastewater was introduced to evaluate treatment efficiency for system B composing of dual RBCs and tapered aeration tanks for 50 days of experimental run time, in which hydraulic rates were maintained at the constant ratios of 346L/day, 50% of internal return and 50% of sludge return. The spiral string media made of nylon fibre was attached by Bacillus sp. in RBC for both systems. The specific area of string media was $1.4m^2$/m and biomass was maintained at the concentrations of 23g/m. The synthetic wastewater was supplied by 1,800mg/L of glucose, 500mg/L of $NH_4Cl$, and 500mg/L of $KH_2PO_4$ to system A. The dairy wastewater was supplied to system B from dairy production plant. The average influent concentrations were 1,334mg/L of BOD, 2,014mg/L of CODcr, 160mg/L of T-N, and 12mg/L of T-P in system A. The average influent concentrations of parameters were 1,006 mg/L for BOD, 1,875mg/L for $COD_{cr}$, 51.6mg/L for T-N and 8.9mg/L for T-P in system B. Results indicated that removal efficiencies of BOD and $COD_{cr}$ were more than 90% however, the removal efficiency of T-N was 87%, and that of T-P was 82% for system A. Removal efficiencies were 98.5% of BOD, 91.3% of nitrogen and 89% of phosphorus for system B. The removal efficiencies of organic matters, T-N and T-P were higher in system B than in system A. The effluent quality issued by the stringent national legislations for the discharge of the high strength of dairy products wastewater can be improved using sequential RBCsand tapered aeration reactors rather than a single RBC and tapered aeration reactors with Bacillus sp.

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

Food Processing Wastewater Treatment with Ejector-Type Aerator (Ejector형 포기장치를 이용한 식품가공폐수를 처리)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.221-225
    • /
    • 1999
  • This study was conducted to evaluate the treatment efficiency including reaction kinetics and hydraulic characteristics of food processing wastewater by using an ejector-type aeration system (ETAS) in activated sludge process. The oxygen transfer efficiency in ETAS can be changed in accordance with the depth of reactor. However, the optimum air velocity was found less than 1.82 m/hr at a superficial liquid velocity of 634 m/hr. The ETAS process showed higher organic material removal efficiency than that of the existing activated sludge process under hydraulic detention time 6 to 12 hours. This process, which can maintain MLVSS highly, is able to have high organic material removal efficiency at short HRT and deal with variable organic material loading.

  • PDF

Comparison of physical cleaning applied to chemical backwashing of wastewater reuse membrane system (하수재이용 막여과 공정에서 약품 역세에서의 물리세정 영향 비교 평가)

  • Lee, Chang-Ha;Kim, Young-Hoon;Jeon, Min-Jung;Lee, Yong-Soo;Jang, Am;Kim Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.981-987
    • /
    • 2011
  • Biologically treated water contains a large quantity of organic matters and microorganisms which can cause various problems to membrane. The membrane fouling occurred by these reasons is hard to control by single physical cleaning. This study analyzes the efficiency of aeration with chemical backwashing and foulants removal during chemical backwashing. The cleaning efficiency improves when the chemical concentration is high and the contact time of chemical is long. Chemical backwashing with aeration shows exceptional cleaning efficiency which leads the physical cleaning is required during chemical backwashing since it forms flow inside the membrane submerged tank. From the foulants removal analysis, the particles such as turbidity and TOC removal rate increase when the aeration is applied. Dissolved matter of DOC and UV254 removal is dependent on higher chemical concentration. According to FTIR analysis, one of major foulants, the polysaccharide is controlled by the chemical backwashing with aeration condition.

Observations of Treatment Efficiency and Fouling in Submerged Membrane Filtration Treating High-Turbidity Source Water (고탁도 원수대응 침지식 멤브레인 여과에서 공기폭기 및 용액조성에 따른 파울링 및 처리효율 관찰)

  • Jang, Hoseok;Byun, Youngkwon;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.77-83
    • /
    • 2017
  • Transient behavior of fouling resistance was observed with a laboratory-scaled, submerged microfiltration membrane system treating high-turbidity source water consisting of inorganic silica particles and humic acid. Fouling mitigation efficiency with inorganic silica particles caused by aeration was reduced significantly as both humic acid and calcium ion existed together. Scanning electron microscopic observations showed that humic acid was adsorbed onto the surface of inorganic silica particles in the presence of calcium. Turbidity removal was achieved almost completely by submerged MF system regardless of feed compositions. However, the $UV_{254}$ removal of humic acid was improved in the presence of both calcium and inorganic silica particles. Additionally, increasing air-flow rate tended to increase $UV_{254}$ removal efficiency higher than 80%. This may be caused by back-transport of humic acid enhanced by inorganic silica particles providing surface for organic adsorption in the presence of calcium.

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).

Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.