Case Studies of Mass Concentration Variation in the Central-Southern Korean Peninsula Caused by Synoptic Scale Transport of Dust Storms

  • Kim, Hak-Sung;Cho, Jae-Hee
    • Journal of the Korean earth science society
    • /
    • v.40 no.4
    • /
    • pp.414-427
    • /
    • 2019
  • In East Asia, the long-range transport of dust storms originating from Mongolia and northern China affects airborne dust loadings over downwind areas in the southern Korean Peninsula. Since 1997, dust loading cases caused by dust storms have been observed using the thresholds of total suspended particles (TSP, ${\geq}250{\mu}g\;m^{-3}\;hr^{-1}$) and particulate matter less than $10{\mu}g$ ($PM_{10}$, ${\geq}190{\mu}g\;m^{-3}\;hr^{-1}$) in the central-southern Korean Peninsula. There were two dust loading cases that exceeded these thresholds in 2016 and three in 2017, which reflects the downward trend of the last twenty-one years in the central-southern Korean Peninsula. Furthermore, five other dust loading cases with mass concentrations lower than the thresholds were observed from 2016 to 2017. In the moderate dust loading cases exceeding the thresholds, a descending motion of cut-off lows below $45^{\circ}N$ and a southward trough at 500 hPa gpm isopleths intensified at the western ridge, and largely extended the surface high-pressure system over southeast China. Airborne dust loadings following pronounced north-westerlies in the forward side of the high-pressure system were transported to the surface of the central-southern Korean Peninsula. However, in slight dust loading cases lower than the thresholds, the restricted descending motion of cut-off lows over $45^{\circ}N$ and the southwestward trough at 500 hPa gpm isopleths intensified the zonal flow over the Korean Peninsula. Surface high- and low-pressure systems moved eastward from the source compared to moderate dust loading cases. Due to the zonal movement of dust storms traversing eastern China, slight dust loading cases were observed with relatively higher ratios of $PM_{2.5}/TSP$ and carbon monoxide (CO) in the central-southern Korean Peninsula.

Student Exposure to Airborne Dusts in Classroom of Middle Schools (중학교 학생들의 분진폭로에 관한 조사연구)

  • 이영길;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.2
    • /
    • pp.25-33
    • /
    • 1987
  • This study was carried out to evaluate student exposures to dust in classroom of middle schools. A total of four schools, such as two in an urban and two in a rural area, were selected for this study. In this study, airborne dust concentrations were measured during a period from July 8 to July 18, 1986. Additional measurements of dust concentrations were conducted from November 4 to 7, 1986 to compare the results by seasonal variation. The results of this study were as follows. 1. Respirable dust concentrations were measured by both filtration method (C mg/m$^3$) and Digital Aerosol Monitor (cpm) to calculate anexchange factor K. K- value was 0.159 as follows. $K=\frac{c}{cpm} = \frac{2.71}{17.09} = 0.159$ 2. In summer when windows were opened, the concentrations of airborne respirable dusts measured by filter sampling method were 0.54-1.37 mg/m$^3$ in the morning and 0.79-1.75 mg/m$^3$ in the afternoon. Thus, higher levels were indicated in the afternoon. Meanwhile, the concentrations of airborne respirable dusts measured in winter were approximately twice as high as those in summer. 3. The highest dust concentrations were determined in School D which is a coeducational school with classroom of concrete floor. Walking roads in School D were not paved and students did not wear indoor-shoes. Dust levels in School D were approximately twice as high as levels in School B. All of the measured dust levels in four schools exceeded Korean Standard for outdoor air, 0.3 mg/m$^3$ for 24 hours. Results by Digital Aerosol Monitor indicated that there was no significant difference in dust levels among grades. The concentration of airborne dusts in the classroom was 1.5-3.0 times higher than that in the hall way. The concentration of airborne dusts during recess was 1.3-1.6 times higher than that during class. In winter, the dust concentrations during clean-up exceeded the permissible exposure limit, 10 mg/m$^3$ (as total dusts), for occupational exposures. 4. The concentrations of total dusts measured in winter were 1.5-2.4 times higher than those of respirable dusts measured simultaneously.

  • PDF

A Study of Heavy Metal Pollutants in the Respirable Dust in Seoul Area (호흡성분진중의 중금속 오염도에 관한 조사연구)

  • Lim, Young-Wook;Chung, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.68-78
    • /
    • 1989
  • The heavy metal of suspended particulates with human health has long been studied in environmental interest concerned. This study was intended to identify harmful heavy metals of the ambient air borne dusts which were related with the respirable sizes in the aerodynamics. Two sampling sites were selected comparatively; one was in the Shinchon area, which is the commercial district with heavy traffic and the other site was in the Bulgwang area which is residential area. The supended particulates were sampled by high volume air sample with 6 cascade impactor stages. The heavy metals in terms of As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, V and Zn were determined by stomic absorption spectrometry or inductively coupled plasma emission spectrometry. The samples weretaken bimothly for seven consecutive days from May 1987 to March 1988. The annual average concentration of the respirable suspended dust of which diameter is less than 10$\mum$ was 152.59 $\mug/m^3$ of the Shinchon air samples; the respirable dust was equivalent to approximately 85% of the total suspended particulates. The annual average concentration of the respirable suspended dust of the Bulgwang air samples was 112.56 $\mug/m^3$; that was approximately 86% of the total suspended particulates. The concentration of heavy metals was investigated in relation to the particle size. The concentration of Cr, Fe, Mn and V were tended to be much more in the coarse particles than in the fine particles. Cd and Pb in the fine particles were more than in the coarse particles. In the partial correlation coefficients; in the Shinchon area, high correlations among Fe, Se and Mn were determined; it is assumed that those sources would be originated from coal, gasolineand diesel. In Bulgwang area, would be high correlation among Fe, Se, Hg and Mn considered to be originated from coal, Bunker-C and heavy oil as well. From the above results, the hazardous heavy merals in air should be measured and controlled in originally their sources.

  • PDF

Analysis of Meteorological Characteristics by Fine Dust Classification on the Korean Peninsula, 2015~2021 (2015년~2021년 한반도 고농도 미세먼지 사례의 유형분류에 따른 기상학적 특징 분석)

  • Jee, Joon-Bum;Cho, Chang-Rae;Kim, Yoo-Jun;Park, Seung-Shik
    • Atmosphere
    • /
    • v.32 no.2
    • /
    • pp.119-133
    • /
    • 2022
  • From 2015 to 2021, high-concentration fine dust episodes with a daily average PM2.5 concentration of 50 ㎍ m-3 or higher were selected and classified into 3 types [long range transport (LRT), mixed (MIX) and Local emission and stagnant (LES)] using synoptic chart and backward trajectory analysis. And relationships between the fine particle data (PM2.5 and PM10 concentration and PM2.5/PM10 ratio) and meteorological data (PBLH, Ta, WS, U-wind, and Rainfall) were analyzed using hourly observation for the classification episodes on the Korean Peninsula and the Seoul metropolitan area (SMA). In LRT, relatively large particles such as dust are usually included, and in LES, fine particle is abundant. In the Korean peninsula, the rainfall was relatively increased centered on the middle and western coasts in MIX and LES. In the SMA, wind speed was rather strong in LRT and weak in LES. In LRT, rainfall was centered in Seoul, and in MIX and LES, rainfall appeared around Seoul. However, when the dust cases were excluded, the difference between the LRT and other types of air quality was decreased, but the meteorological variables (Ta, RH, Pa, PBLH, etc.) were further strengthened. In the case of the Korean Peninsula, it is difficult to find a clear relationship because regional influences (topographical elevation, cities and coasts, etc.) are complexly included in a rather wide area. In the SMA, it is analyzed that the effects of urbanization such as the urban heat island centered on Seoul coincide with the sea and land winds, resulting in a combination of high concentrations and meteorological phenomena.

A Study on the Size Distribution and Chemical Component of Suspended Particulate during the Period of Sandy Dust Phenomena (黃砂現象時 粉塵의 粒度分布와 化學組成에 關한 硏究)

  • Lee, Min-Hee;Han, Eui-Jung;Shin, Chan-Ki;Han, Jin-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.57-66
    • /
    • 1988
  • Sandy dust phenomena was observed from April 19 to 23, 1988 in Seoul and suspended particulate was collected by Andersen air sampler during this period. The samples were analyzed for 16 components $(SO_n^{2-}, NO_3^-, Cl^-, PO_4^{3-}, NH_4^+, F^-, Al, Fe, K, Cu, Mn, Na, Pb, Mg, Ca, Cd)$. The conclusions are as follwes: 1. Total suspended particulate concentation during the period of sandy dust phenomena was 489 $\mug/m^3$ (ordinary times: 140-125 $mug/m^3$) 2. The water - soluble ion component concentration of suspended particulate during the period of sandy dust phenomena was few and the metal concentration of that was more than that of ordinary times. 3. The cumulative frequency distribution of suspended particulates in logarithmic diagram did not show similar to normal log distribution during the period of sandy dust phenomena. 4. $SO_4^{2-}, NO_3^-, Cl^-, and PO_4^{3-}$ was onsided to coarse particle, and $NH_4^+$ and F to fine particle in the size distribution of water - soluble ion components during the period of sandy dust phenomena. 5. Metal concentration was high and Al, Fe, Cu, Mn, Na, Mg, and Ca was onsided to coarse particle, and K, Pb, and Cd to fine particle in the size distribution of metal components. 6. During the period of sandy dust phenomena the quantity of respirable particle (< 1 $\mum$) was about 3 times and that of metal components were about 2 - 11 times than that of ordinary times. 7. The concentrations of $NO_3^-, Cl^-, NH_4^+$ at ordinary times were 1.1 - 4 time than that of the period of sandy dust phenomena.

  • PDF

Performance Analysis of Simulation of Asian Dust Observed in 2010 by the all-Season Dust Forecasting Model, UM-ADAM2 (사계절 황사단기예측모델 UM-ADAM2의 2010년 황사 예측성능 분석)

  • Lee, Eun-Hee;Kim, Seungbum;Ha, Jong-Chul;Chun, Youngsin
    • Atmosphere
    • /
    • v.22 no.2
    • /
    • pp.245-257
    • /
    • 2012
  • The Asian dust (Hwangsa) forecasting model, Asian Dust Aerosol Model (ADAM) has been modified by using satelliate monitoring of surface vegetation, which enables to simulate dusts occuring not only in springtime but also for all-year-round period. Coupled with the Unified Model (UM), the operational weather forecasting model at KMA, UM-ADAM2 was implemented for operational dust forecasting since 2010, with an aid of development of Meteorology-Chemistry Interface Processor (MCIP) for usage UM. The performance analysis of the ADAM2 forecast was conducted with $PM_{10}$ concentrations observed at monitoring sites in the source regions in China and the downstream regions of Korea from March to December in 2010. It was found that the UM-ADAM2 model was able to simulate quite well Hwangsa events observed in spring and wintertime over Korea. In the downstream region of Korea, the starting and ending times of dust events were well-simulated, although the surface $PM_{10}$ concentration was slightly underestimated for some dust events. The general negative bias less than $35{\mu}g\;m^{3}$ in $PM_{10}$ is found and it is likely to be due to other fine aerosol species which is not considered in ADAM2. It is found that the correlation between observed and forecasted $PM_{10}$ concentration increases as forecasting time approaches, showing stably high correlation about 0.7 within 36 hr in forecasting time. This suggests the possibility that there is potential for the UM-ADAM2 model to be used as an operational Asian dust forecast model.

Infrared Spectral Signatures of Dust by Ground-based FT-IR and Space-borne AIRS (지상 및 위성 고분해 적외스펙트럼 센서에서 관측된 황사 특성)

  • Lee, Byung-Il;Sohn, Eun-Ha;Ou, Mi-Lim;Kim, Yoon-Jae
    • Atmosphere
    • /
    • v.19 no.4
    • /
    • pp.319-329
    • /
    • 2009
  • The intensive dust observation experiment has been performed at Korea Global Atmosphere Watch Center (KGAW) in Anmyeon, Korea during each spring season from 2007 to 2009. Downward and upward hyper-spectral spectrums over the dust condition were measured to understand the hyper-spectral properties of Asian dust using both ground-based Fourier Transform Infrared Spectroscopy (FT-IR) and space-borne AIRS/Aqua. To understand the impact of the Asian dust, a Line-by-Line radiative transfer model runs to calculate the high resolution infrared spectrum over the wave number range of $500-500cm^{-1}$. Furthermore, the radiosonde, a $PM_{10}$ Sampler, a Micro Pulse Lidar (MPL), and an Aerodynamic Particle Sizer (APS) are used to understand the vertical profile of temperature and humidity and the properties of Asian dust like concentration, altitude of dust layer, and size distribution. In this study, we found the Asian dust distributed from surface up to 3-4 km and volume concentration is increased at the size range between 2 and $8{\mu}m$ The observed dust spectrums are larger than the calculated clear sky spectrums by 15~60K for downward and lower by around 2~6K for upward in the wave number range of $800-1200cm^{-1}$. For the characteristics of the spectrum during the Asian dust, the downward spectrum is revealed a positive slope for $800-1000cm^{-1}$ region and negative slope over $1100-1200cm^{-1}$ region. In the upward spectrum, slopes are opposed to the downward one. It is inferred that the difference between measured and calculated spectrum is mostly due to the contribution of emission and/or absorption of the dust particles by the aerosol amount, size distribution, altitude, and composition.

High Influential Factor of Cadmium and Lead Exposure in Outdoor Workers (옥외 근로자들의 카드뮴과 납 노출 영향요인)

  • Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.163-173
    • /
    • 2020
  • Objectives: The study was evaluated exposure variation and daily absorption level of cadmium, lead concentration of ambient air of monthly data from 1999 to 2017 for main exposure factor in outdoor workers. Methods: Based on the monthly data from 'The annual report of air quality in Korea from 1999 to 2018' in 'Air Korea' website in the Korean Ministry of Environment. The monthly data of PM2.5, PM10, cadmium, lead concentration of ambient air were recalculated to average, minimum, and maximum. And these data were combined to Asian-dust exposure data from 'The annual report of Asian-dust·smog in 2017' of National Institute of Meteorological Sciences in Korea. Results: Geometric mean(minimum-maximum) concentration in ambient air of monthly data were 0.0017 (ND-0.2015) mg/㎥ in cadmium and 0.0467(ND-0.8554) mg/㎥ in Pb from 1999 to 2017. Both of Cd and Pb concentration in ambient air showed the highest concentration in January and the lowest in August among annual variation from 1999 to 2017. PM10 and PM2.5 level showed the highest in March(PM10) and February (PM2.5) the lowest in August both of PM10 and PM2.5. Discussion: Based on exposure data and prior reports, daily Cd absorption was estimated to 0.013(ND-1.511) mg/day from respiration and 1.89 mg/day from daily food(25.2 mg/day of daily Cd intake). In case of Pb, daily absorption was estimated to 0.350(ND-6.416) mg/day from respiration and 1.38-1.71 mg/day from daily food intake. Conclusion: Cd and Pb with Asian-dust have high influential factor to increase the Cd and Pb exposure at Winter and Spring season in outdoor workers.

Regional and Sex Differences in Cognition and Wear Behavior Concerning Fine-dust Protective Masks during High Concentration Days (미세먼지 고농도 시즌 방진용 마스크에 관한 인식과 착용 행동에서 전국 지역별 차이 및 성차)

  • Lee, Joo-Young;Park, Joonhee;Baek, Yoon Jeong;Jung, Dahee;Ko, Yelin;Jung, Jae Yeon;Kang, Juho;Lee, Taekyung;Lee, Yejin;Song, Eunyoung;Son, Su-Young;Kwon, Juyoun;Kim, Sun-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.3
    • /
    • pp.516-538
    • /
    • 2020
  • The present study investigated regional and sex differences in knowledge, perception, cognition and behavior of fine-dust protective masks for periods of high concentration of fine dust in Korea. A total of 2,012 adults from seven provinces responded to the questionnaire. The results (all p<.05) showed that 78% of respondents considered pollution from China to be the greatest contributor of fine dust. Seoul and Gyeonggi residents more frequently checked fine dust forecasts than other provinces and consulted their smartphone applications to do so more than other residents. Jeju, Gwangwon, and Jeonla residents had less knowledge of KF 80, 94, and 99 masks than residents of other provinces. Gwangwon and Jeju residents had less trust in the effectiveness of protective masks than other residents. Females perceived themselves as unhealthier respiratory, more frequently checked the concentration of fine dust, trusted more the effectiveness of masks, and more frequently wore masks, compared to male respondents. Those who self-identified their respiratory function as poor, more frequently checked fine dust forecasting, and had greater knowledge of masks, which resulted in greater trust in the protective function of masks, and finally had higher wear frequency of masks for days with high concentrations of fine dust.

Comparison of High Concentration Prediction Performance of Particulate Matter by Deep Learning Algorithm (딥러닝 알고리즘별 미세먼지 고농도 예측 성능 비교)

  • Lee, Jong-sung;Jung, Yong-jin;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.348-350
    • /
    • 2021
  • When predicting the concentration of fine dust using deep learning, there is a problem that the characteristics of a high concentration of 81㎍/m3 or more are not well reflected in the prediction model. In this paper, a comparison through predictive performance was conducted to confirm the results of reflecting the characteristics of fine dust in the high concentration area according to the deep learning algorithm. As a result of performance evaluation, overall, similar levels of results were shown, but the RNN model showed higher accuracy than other models at concentrations of "very bad" based on AQI. This confirmed that the RNN algorithm reflected the characteristics of the high concentration better than the DNN and LSTM algorithms.

  • PDF