• Title/Summary/Keyword: High Concentration Dust

Search Result 289, Processing Time 0.024 seconds

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

PM10 β-ray attenuation samplers (β-ray absorption method) equivalence evaluation and comparatively observed study (PM10 연속자동측정기(β-ray) 등가성평가 및 비교관측 연구)

  • WonSeok Jung;Hee-Jung Ko;Wonick Seo;Jiyoung Jeong;Sang Min Oh;Kyung-On Boo
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • The Asian dust observation network operates β-ray attenuation samplers to measure PM10 concentrations. In addition, equivalence evaluation and accuracy inspection(Precision Tests) are conducted every year for the reliability of data. β-ray attenuation samplers(16 units) were comparatively observed from May to June 2020 and from July to December 2021. During the observation period, the average daily temperature was the lowest at 6.4℃ in December and the highest at 27.3℃ in August. The average daily humidity ranged from 60% to 100%, but the average daily humidity was over 75% from July to September. The minimum value of the PM10 Gravimetric method was 5.0 ㎍/m3, the maximum value was 53.4 ㎍/m3, and the average value was 17.8 ㎍/m3. The equivalence evaluation results of the PM10 Gravimetric method and β-ray attenuation samplers satisfied the criteria (slope: 1±0.1, intercept: 0±0.5). A relative error analysis between the PM10 Gravimetric method and β-ray attenuation samplers equipment showed that the relative error increased when the concentration was low and the temperature and humidity were high. In addition, in the β-ray attenuation samplers 5-minute interval observation data in May 2020, a relatively large Standard devication was shown as an average maximum ±23.4 ㎍/m3 and a minimum ±15.2 ㎍/m3. At standard deviations of 10% and 90%, equipment with high variability (deviation) was measured at 6 ㎍/m3and 61 ㎍/m3, and equipment with low variability was measured at 12 ㎍/m3 and 47 ㎍/m3. It was confirmed that concentration differences occurred due to differences in variability for each equipment.

Compositions of haze aerosols and their variation by inflow pathway of air mass at Gosan site in Jeju Island during 2012-2013 (연무 에어로졸의 조성 및 기류 유입경로별 변화: 2012-2013년 제주도 고산지역 측정)

  • Hyeon, Dong-Rim;Song, Jung-Min;Kim, Ki-Ju;Kim, Won-Hyung;Kang, Chang-Hee;Ko, Hee-Jung
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.213-222
    • /
    • 2014
  • The atmospheric aerosols of $PM_{10}$ and $PM_{2.5}$ were collected at Gosan site of Jeju Island during 2012- 2013. Their ionic and elemental species were analyzed in order to examine the composition variation of the haze aerosols in accordance with the pathway of air mass. The concentrations of $nss-SO_4{^{2-}}$, $NO_3{^-}$, and $NH_4{^+}$ increased 2.1~3.7 times in coarse particle and 3.1~6.5 times in fine particle modes, respectively, showing especially high $NO_3{^-}$ concentrations in fine particles during the haze days. The concentrations of S, Zn, Pb and K increased 3.0~5.6 times in coarse particles and 3.2~7.7 times in fine particles during the haze days, on the other hand Al, Fe, and Ca concentrations were high only in coarse particles. Due to the back trajectory analysis, the concentrations of $nss-SO_4{^{2-}}$ and $NO_3{^-}$ for haze days were high when the inflow pathway of air mass was from China, especially a high increase of $NO_3{^-}$ as through the south of China. The $NO_3{^-}/nss-SO_4{^{2-}}$ concentration ratio was relatively high in coarse mode as air mass inflow from China, but in fine mode it was high as air mass passing through the Korean peninsula.

Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure (젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구)

  • Kang, Ho;Kim, Sun-Woo;Jeong, Ji-Hyun;Ahn, Hee-Kwon;Jung, Kwang-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.696-704
    • /
    • 2015
  • This study was carried out to evaluate the optimum operational condition of Semi-continuously Fed and Mixed Reactor (SCFMR) to treat the dairy cow manure and saw dust mixture. Step-wise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) were utilized until the biogas volume became significantly decreased at mesophilic temperature ($35^{\circ}C$). The optimum operating condition of the SCFMR fed with TS 13% dairy cow manure and saw dust mixture was found to be an HRTs of 25 days and its corresponding OLRs of $4.45kg\;VS/m^3-day$. At this condition the biogas and methane production rates were 1.44 v/v-d and 1.12 v/v-d (volume of biogas per volume of reactor per day), respectively and the TVS removal efficiency of 37% was achieved. The successful operation with such a high OLR was due to the high reactor alkalinity concentration of 14,500~15,600 mg/L as $CaCO_3$ as a result of the characteristic of the original substrate, dairy cow manure and saw dust mixture whose alkalinity was more than 8,000 mg/L as $CaCO_3$. The parameters for the reactor stability, the ratios of volatile acids and alkalinity concentrations (V/A) and the ratio of propionic acid and acetic acid concentrations (P/A) appeared to be 0.11 and 0.43, respectively, that were greatly stable in operation. Free ammonia toxicity was not experienced due to the long term acclimation by the reactor TS content ranged 7.2~10.4% during the entire operational period.

Analysis of the Association between Air Pollutant Distribution and Mobile Sources in Busan Using Spatial Analysis (공간 분석을 통한 부산광역시 대기오염물질의 분포와 이동오염원 간의 관련성 연구)

  • Jae-Hee Min;Byoung-Gwon Kim;Hyunji Ju;Na-Young Kim;Yong-Sik Hwang;Seungho Lee;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.191-200
    • /
    • 2024
  • Background: Busan is a rapidly industrializing city with many mixed residential and industrial areas. Fine dust emissions from mobile pollution sources such as ships and vehicles are particularly high in Busan. Objectives: This study analyzed the spatial distribution of air pollutants over the past three years and identified the impact of air pollutants through mobile source data in Busan. Methods: We obtained air pollutant data on fine particulate matter (PM10), ultrafine particulate matter (PM2.5), nitrogen dioxide (NO2), sulfurous acid gas (SO2), and ozone (O3) for the last three years (source: airkorea.or.kr) and analyzed the spatial distribution using SAS 9.4 and Surfer 23. For the mobile pollutant data, we used CCTV data from major intersections in Busan to identify truck and car traffic, and visualized traffic density with QGIS. Results: The analysis of the concentration of air pollutants over three years (2020~2022) showed that all were lower than the annual environmental standards with the exception of PM2.5. PM10 and PM2.5 were found to be highly concentrated in the western part of the area, while NO2 was high in the port area of Busan and SO2 was high in the western part of the area and near the new port of Busan. In the case of O3, it was high in the eastern part of the city. The traffic volume of freight vehicles by intersection was concentrated in the West Busan area, and the traffic volume for all cars was also confirmed to be concentrated at "Mandeok Intersection" located in the West Busan area. Conclusions: This study was conducted to determine the relationship between air pollutants emitted from motor vehicles and the distribution of air pollutants in Busan. The spatial distribution of PM10 and PM2.5 correlates with traffic volume, while high concentrations of SO2 and NO2 near the port are associated with ship emissions.

A Study on the Mining Method for Limestone Mines with Less Environmental Hazards (환경오염 저감을 위한 석회석 광산개발방안에 대한 연구)

  • 임한욱;김재동;백환조
    • Tunnel and Underground Space
    • /
    • v.10 no.1
    • /
    • pp.80-91
    • /
    • 2000
  • Open cut mining of limestone is generally considered to be more advantageous than underground mining in recovery, grade control, economics, and safety, but it causes substantial environmental pollutants such as ground vibration, noise, dust. It also changes ground surface and may destroy vegetation. The Halla limestone mine which lies adjacent to Baikdu mountains range is selected for a model study. To reduce environmental hazards, and to conserve original surface and woods, both open cut and underground mining methods must be adopted. In case of sub-level sloping. a unit block of 87m high, 70m wide, and 100∼l20m long is suggested with an estimated overall recovery of 42%. Some suggestions to reduce the environmental hazards are also included. The followings must be considered in determining the degree of fragmentation; the discontinuity conditions in the rock mass and the charge concentration both at the bottom and column of the hole. In addition to adopting a barrier wall for reducing environmental hazards, the probable production from underground mining is also discussed.

  • PDF

Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products (일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도)

  • Kim, Young-Hwan;Suh, Hyung-Joo;Kim, Jin-Man;Jung, Yeon-Hoon;Moon, Kyong-Whan
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.

A Study on Accuracy a Passive NO2 Sampler (NO2간이포집기(簡易捕集器) 정도(精度)에 관(關)한 연구(硏究))

  • Chun, Man-Young;Kang, Gong-Unn;Kim, Hui-Kang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.93-99
    • /
    • 1992
  • Recently a passive $NO_2$ samplers have been frequently used for the measurement of $NO_2$ concentration in the atmosphere because of its simplicity and high accuracy. But these samplers have a defect that the amount of $NO_2$ adsorbed is increased by wind. In this study, the inlet of sampler was covered with a draft shield made by 325 mesh stainless sieve to eliminate the effect. But it was expected that $NO_2$ diffusion was interrupted by the draft shield. In order to conform this phenomenon, samplers with and without draft shield were exposed to a box filled with 1-1.1ppm $NO_2$. The result indicated that draft shield nearly did not disturb $NO_2$ diffusion. To protect samplers from dust, sunshine, precipitation and vertical wind effects, these samplers were placed into a shelter during the field test. The data obtained in this study was compared with the data from the ambient air monitoring network. The coefficient of correlation(r) between the two data was 0.9995 for the test period of up to 35days. The results of this study indicate that the type of $NO_2$ samplers with draft shield in shelter used in this study can be used for measuring $NO_2$ concentrations in the ambient air relatively for a long period over 30 days.

  • PDF

Characteristics of Cyclone-Bag Filter with Bottom Inlet (하부유입식 원심 여과집진장치의 특성)

  • Yoa, Seok-Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.639-650
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of cyclone-bag filter with bottom inlet to decrease the high pressure drop which was one of main problems of fabric bag filter. The experiment was executed for the analysis of collection efficiency and pressure drop(specially, pressure drop of fabric filter) characteristics of the cyclone-bag filter in comparison with those of general fabric bag filter with various experimental parameters such as the inlet velocity, dust loading and variation of vortex region, etc. In the results, the tangential inlet type showed higher collection efficiency for submicron particles below $1{\mu}m$ in diameter than of center inlet, and over 99% for overall collection efficiency. For the inlet particle concentration $100mg/m^3$, pressure drop reduction ratios were shown as 15~38% with the inlet velocity in case of large bag, while 30~48% for small bag due to the increase of vortex region.

  • PDF

Particulate Matter Prediction using Quantile Boosting (분위수 부스팅을 이용한 미세먼지 농도 예측)

  • Kwon, Jun-Hyeon;Lim, Yaeji;Oh, Hee-Seok
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.1
    • /
    • pp.83-92
    • /
    • 2015
  • Concerning the national health, it is important to develop an accurate prediction method of atmospheric particulate matter (PM) because being exposed to such fine dust can trigger not only respiratory diseases as well as dermatoses, ophthalmopathies and cardiovascular diseases. The National Institute of Environmental Research (NIER) employs a decision tree to predict bad weather days with a high PM concentration. However, the decision tree method (even with the inherent unstableness) cannot be a suitable model to predict bad weather days which represent only 4% of the entire data. In this paper, while presenting the inaccuracy and inappropriateness of the method used by the NIER, we present the utility of a new prediction model which adopts boosting with quantile loss functions. We evaluate the performance of the new method over various ${\tau}$-value's and justify the proposed method through comparison.