• Title/Summary/Keyword: High Concentration Dust

Search Result 290, Processing Time 0.027 seconds

Study on Combustion and Explosion Hazard of Rice Bran Dusts (쌀겨 분진의 연소 및 폭발 위험성에 관한 연구)

  • 이창우;현성호;이한철;허윤행
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.93-98
    • /
    • 1999
  • We had investigated combustion properties of rice bran dusts. Decomposition of rice bran dusts with temperature were investigated using DSC and the weight loss according to temperature using TGA in order to find the thermal hazard of rice bran dusts, and the properties of dust explosion in variation of their dust with the same particle size. Using Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of rice bran dust.According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Average maximum explosion pressure was $10kgf/cm^2$ for 60/70 mesh and $1.5mg/cm^2$ dust concentration.

  • PDF

Fine Dust Adsorption of Cement Matrix Using Sepiolite (세피올라이트를 활용한 시멘트 경화체의 미세먼지 흡착 특성 )

  • Jeon, Eun-Yeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.71-72
    • /
    • 2023
  • As industrialization and urbanization accelerate, environmental issues have moved from local concerns to global issues. Among them, air pollution is the most important issue. Modern people spend more than 88% of their day indoors, but the concentration of fine dust and pollutants flowing indoors is increasing. The indoor environment has its own complexity, and various substances used indoors, such as building materials, furniture, electronics, and cleaning agents, emit chemical substances and cause various diseases. Therefore, when selecting building materials and interior finishing materials, the pollutant emission and adsorption capacity must be greatly considered. These considerations will ensure the construction of a sustainable future environment and a healthy life within that environment. Therefore, in order to reduce the generation of indoor air pollutants, this study aims to examine the fine dust adsorption properties of cement hardening materials using sepiolite, which has a porous structure and high absorption power among clay minerals. As a result of the experiment, it was found that the concentration of fine dust decreased as the addition rate of sepiolite increased. It is believed that the fine dust concentration was reduced due to the high porosity due to the microfibrous structure and large specific surface area of sepiolite, which has a porous structure among clay minerals. It is believed that these experimental results can be used as basic research for future use of sepiolite as a construction material.

  • PDF

Measurement and Analysis of Dust Concentration in a Fattening Pig House Considering Respiratory Welfare of Pig Farmers (비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Ha, Tae-Hwan;Ha, Jung-Soo;Park, Se-Jun;Jo, Ye-Seul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.5
    • /
    • pp.25-35
    • /
    • 2013
  • In swine house, dust generation comes from various sources and is known to be harmful both for the animals and the farmers because the dust contains biological and gaseous matters. When farmers are constantly exposed to the dusts, they can suffer chronic or acute respiratory symptoms and have high probability of manifesting various diseases. To address this problem, understanding of the mechanism of dust generation is very important. In this paper, the dust concentration of inhalable, respirable, TSP and $PM_{10}$ were monitored and analyzed according to the pig-activity level, ventilation quantity and feeding method in fattening pig house. From the measured results, in case of the concentration of TSP, an inverse-linear relation with ventilation rate ($R^2=0.88$) and linear relation with the installation height of feed supply pipe ($R^2=0.73$) were determined. However in case of the concentration of $PM_{10}$, no particular relationship with the variables was observed. Using the concentration of inhalable and respirable dust based on the pig-activity level, multi-variate regression analysis was conducted and results have shown that the movement of pigs can contribute to the dust generation (p<0.05, $R^2=0.71$, 0.61). The relationship determined between dust generation and environmental variables investigated in this study is very significant and useful in conducting dust-reduction researches.

Comparison of ADAM's (Asian Dust Aerosol Model) Results with Observed PM10 Data (황사농도 단기예측모델의 PM10 농도와 실측 PM10 농도의 비교 - 2006년 4월 7~9일 황사 현상에 대해 -)

  • Cho, Changbum;Chun, Youngsin;Ku, Bonyang;Park, Soon-Ung;Lee, Sang-Sam;Chung, Yun-Ang
    • Atmosphere
    • /
    • v.17 no.1
    • /
    • pp.87-99
    • /
    • 2007
  • Simulation results of Asian Dust Aerosol Model (ADAM) for the period of April 7-9, 2006 were analyzed, comparing with observed PM10 data. ADAM simulated around ten times lower than on-site PM10 concentration in the source regions: Zhurihe, Tongliao, Yushe, Dalian and Huimin. As the result of this low concentration, transported amounts of Asian Dust were under-estimated as well. In order to quantify a forecasting accuracy, Bias and RMSE were calculated. Even though remarkably negative Biases and high RMSEs were observed, ADAM simulation had followed well up the time of dust outbreak and a transported path. However, the emission process to generate dust from source regions requires a great enhancement. The PM10 concentration at the surface reached up to $2,300{\mu}gm^{-3}$ at Baeknyoungdo and Seoul (Mt. Gwanak), up to $1,750{\mu}gm^{-3}$ at KGAWO about 18:00 LST in April 8, respectively; however, ADAM did not simulate the same result on its second peak. It is considered that traveling Asian dust might have been lagged over the Korean peninsula by the blocking of surface high pressure. Moreover, the current RDAPS's 30 km grid resolution (which ADAM adopts as the meteorological input data) might not adequately represent small-scale atmospheric motions below planetary boundary layer.

The Air Quality Analysis in Underground Shopping Centers Using Pattern Recognition (Pattern Recognition을 이용한 지하상가에서의 대기오염물질의 농도 분석에 관한 연구)

  • 김동술;김형석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 1990
  • The purpose of the study was to analyze air quality in underground shopping centers using pattern recognition methods. In order to perform this, the concentraion of air pollutants such as $CO, NO_2, NO_x, SO_2$, and particulate matters was measured at the 11 different shopping centers in Seoul metropolitan area and the total of 47 samples were obtained at random based on the size of shopping centers. To introduce a new concept of the "average concentration" for the indoor air quality analyses, the various multivariate statistical analyses have been studied. Thus, a cluster analysis was applied to separate the samples into pseudo-patterns and a disjoint principal component analysis was used to generate homogeneous patterns after removing outliers from the pseudo-patterns. The 6 homogeneous patterns were then obtained as follows:the first pattern was a group of clean sites;the second a group of sites having high dust concentration;the third a group of sites having high dust and $NO_x$ concentration;the fourth a group of sites having low dust and $SO_2$ concentraion and high CO concentration;the fifth a group of sites having high $NO_2 and SO_2$ concentration;and the final a group of miscellaneous sites. Thus, the average concentration could be estimated for each pattern.h pattern.

  • PDF

DETECTION OF DUST LOADED AIRMASS IN SEAWIFS IMAGERY: AN EMPIRICAL DUST INDEX IN COMPARISON WITH MODEL-PREDICTED DUST DISTRIBUTION OVER THE PACIFIC IN APRIL,1998

  • Fukushima, H.;Schmidt, M.;Sohn, B.J.;Toratani, M.;Uno, I.
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.89-94
    • /
    • 1999
  • The paper first proposes an empirical algorithm for detecting dust-loaded airmass observed by Sea Wide Field-of-view Scanner (SeaWiFS). The proposed dust index formula is based on the curvature of the spectral reflectance estimated from the SeaWiFS band 4 (510 nm band) through band 8 (865 nm band) data, assuming "clear ocean water" reflectance. Evaluation of the algorithm is made over several typical Asian dust images including the ones over the Pacific in April, 1998, when a major dust event was reported. The study analyzes the performance and the characteristics of the algorithm by comparing the satellite-derived dust index images with contemporaneous columnar concentration of dust particles predicted by a numerical dust transport model. The comparison reveals several small-scale differences although their dust distribution patterns show good agreement generally.

  • PDF

An analysis on the distribution characteristics of PM10 concentration and its relation to the death from Asthma in Seoul, Korea (서울지역 PM10 농도의 분포 특성과 천식 사망자 수의 상관성 분석)

  • Park, Jong-Kil;Choi, Yun-Jeong;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.961-968
    • /
    • 2015
  • The production of highly concentrated $PM_{10}$ is in the spotlight as a social issue, and it increases the attack rate of Asthma. This study aimed to analyze the characteristics of concentration and distribution for $PM_{10}$ from 2000 to 2011, and investigate its correlation with the death from Asthma. Furthermore, this study was designed to analyze it by dividing into two cases like including Asian dust and excluding Asian dust because it presented the high concentration when Asian dust was occurred in the spring. This study has found that the annual average concentration distribution of $PM_{10}$ in Seoul was higher in the central area than the peripheral area. The annual average concentration of $PM_{10}$ and death from asthma displayed the tendency to gradually decrease. The correlation coefficient for all period was 0.92(p=0.000), and the correlation was 0.84(p=0.001) in case of remove Asian dust. The monthly average concentration of $PM_{10}$ has increased in the winter and decreased in the summer. The death from Asthma and correlation coefficient for all period was 0.588(p=0.044) and 0.640(p=0.025) in case of removing Asian dust. Although the causes of Asthma had a great diversity, the similar tendency by a factor of $PM_{10}$ meant that the correlation was high.

Estimation of Heavy Metal Contamination by PM10 Inflow Pathways while Asian Dust in Gwangju (광주지역 황사시 미세먼지 유입경로별 중금속 오염도 평가)

  • Yang, Yoon-Cheol;Lee, Se-Haeng;Park, Byoung-Hoon;Jo, Gwang-Un;Yoon, Sang-Hoon;Park, Ji-Young;Jang, Dong;Chong, Ji-hyo;Bae, Seok-Jin;Jeong, Suk-Kyoung
    • Journal of Environmental Science International
    • /
    • v.29 no.1
    • /
    • pp.55-68
    • /
    • 2020
  • The purpose of this study is to investigate the relationship of fine dust PM10 and heavy metals in PM10 in Asian dust flowing into Gwangju from 2013 to 2018. The migration pathways of Asian dust was analyzed by backward trajectory analysis using HYSPLIT (Hybrid Single Particle Lagrangian Integrated Trajectory) model, and the change of heavy metal concentration and heavy metal content per 1 ㎍/㎥ of fine dust PM10 in Gwangju area were analyzed. Also, the characteristics of the heavy metals were analyzed using the correlation between the heavy metals in PM10. As a result of analyzing Asian dust entering the Gwangju region for 6 years, the average concentration of PM10 measured in Asian dust was 148 ㎍/㎥, which was about 4.5 times higher than in non-Asian dust, 33 ㎍/㎥. A total of 13 Asian dust flowed into the Gwangju during 6 years, and high concentration of PM10 and heavy metals in that were analyzed in the C path flowing through the Gobi/Loess Plateau-Korean Peninsula. As a result of the correlation analysis, in case of Asian dust, there was a high correlation between soil components in heavy metals, so Asian dust seems to have a large external inflow. On the other hand, in case of non-Asian dust, the correlation between find dust PM10 and artificial heavy metal components was high, indicating that the influence of industrial activities in Gwangju area was high.

Concentration Characteristics and Health Effect Assessment of Atmospheric Particulate Matters During Asian Dust Storm Episodes (황사 에피소드 발생시 대기먼지의 농도 특성과 인체 영향)

  • Kang, Gong-Unn
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.21-35
    • /
    • 2009
  • The Asian dust storms which originated in the deserts of Mongolia and China transported particles to Korea and led to a high concentration of atmospheric particulate matters (PM) of more than $1000{\mu}g/m^3$ throughout the country in the spring, of 2007. Public concern, in Korea, about the possible adverse effects of these dust events has increased, as these dust storms can contain various air pollutants emitted from heavily industrialized eastern China. The objectives of this study were to understand the concentration characteristics of PM as a function of particle size between the Asian dust storm episodes and non-Asian dust period and to consider the mass size distribution of PM in the Asian dust storms and their water soluble ion species on the potential, possible effects on deposition levels in the three regions (nasopharyngeal, tracheobronchial, and alveolar) of the human respiratory system. The size distribution of PM mass concentration during the Asian dust storms showed a peak in the coarse particle region due to the long-range transport of soil particles from the deserts of Mongolia and China, which was identified by HYSPLIT-4 model for backward trajectory analysis of air arriving in the sampling site of Iksan. During the non-Asian dust period, there were two different types in PM size distribution: bimodal distribution when low concentrations of $PM_{2.5}$ were observed, while unimodal distribution having a peak in fine particle region when high concentrations of $PM_{2.5}$ were showed. This unimodal distribution with high concentrations of fine particulate and secondary air pollutants such as ${SO_4}^{2-}$, ${NO_3}^-$, ${NH_4}^+$ was found to be due to the long-range transport of air pollutants from industrialized eastern China. During the Asian dust storms, the mean concentrations of PM that can be deposited in the nasopharyngeal, tracheobronchial, and alveolar region were $128.8{\mu}g/m^3$, $216.5{\mu}g/m^3$, and $89.6{\mu}g/m^3$, respectively. During the non-Asian dust period, the mean concentrations of PM that can be deposited in the nasopharyngeal, tracheobronchial, and alveolar region were $8.4{\mu}g/m^3$, $9.5{\mu}g/m^3$ and $38.5{\mu}g/m^3$, respectively.

Measurement of Dust Concentration in a Mechanically Ventilated Broiler House and Analysis of Dust Generation from Ground Beds (강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석)

  • Kwon, Kyeong Seok;Jo, Ye Seul;Lee, In Bok;Ha, Tae Hwan;Hong, Se Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.31-43
    • /
    • 2014
  • Confined and mechanically ventilated broiler house has been recently come into wide use to increase productivity and control rearing conditions. However, high dust concentration inside facility can threaten respiratory welfare of farmers and broilers. In Korea, there is no regulation in terms of air quality control inside agricultural facilities and sufficient data is not available. To cope with these, periodic monitoring of inhalable and respirable dust concentration were conducted according to season, broiler's activity and specific events such as shipment work for broilers in mechanically ventilated broiler house. Chamber experiment was also designed to analyze mechanism of dust generation from ground beds according to water contents and surrounding wind environment. Results showed that significant increase of inhalable (p=0.002) and respirable (p=0.03) dust were observed when activity of broilers was high according to entrance of the workers. Even shipment work for matured broilers, high level of dust were observed; inhalable dust was exceeded the threshold limit over maximum 303 % and respirable dust was over maximum 1,550 %, implying that acute respiratory symptoms could be manifested for the workers. From the chamber experiment, critical water contents for interrupting of dust generation were measured; about 45 % for inhalable dust and about 50 % for respirable dust. These results can be a trigger for designing plan of dust control however it still needs consideration of various environmental conditions, hygiene problems, etc.