• Title/Summary/Keyword: High Brightness LED

Search Result 152, Processing Time 0.038 seconds

A Study on the Cell Culture Controller using the High Brightness LED (고휘도 LED를 이용한 세포배양 컨트롤러에 관한 연구)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Song, Chang-Hun;Mun, Seong-Pyo;Kim, Tae-Gon;Park, Yong-Pil;Kim, Dae-Young;Kim, Young-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1149-1153
    • /
    • 2006
  • We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

Design of White Balance Correction Processor for High Resolution Full Color LED Display System (고해상도 천연색 LED 디스플레이 시스템을 위한 흰색 보정프로세서의 설계)

  • Lee, Jong-Ha;Ko, Duck-Young
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.12-18
    • /
    • 2009
  • In this paper, we developed white balance correction processor for Full Color LED Display System which could be display uniformity color and soft light by adjusting brightness of red, green, blue pixel, individually. This processor correct brightness by calculating operating current of each pixel(red, green, blue LED) on the basis of characteristic curve of LED device when we named "a" as a specific characteristic value, "b" as a brightness correction value according to using time, "X" as a operating current value, and "Y" as brightness value. As the results, we solved the reduction problem of brightness for long used LED devices, according to increase entire mean of brightness value by adjusting "b" value from the brightness characteristic function.

Optic Characteristics Comparison and Analysis of SMD Type Y/G/W HB LED (SMD형 Y/G/W HB LED의 광특성 비교분식)

  • 황명근;허창수;서유진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.15-21
    • /
    • 2004
  • The optical characteristics; luminous flux, correlated color temperature, and CIE -chromaticity coordinate etc., of HB LED(high brightness light emitting diode) of yellow/green/white SMD(surface mounted device) type were tested with integrating sphere photometer and monochromator, and the results were comparatively evaluated And, for the white LED, color rendering indices were considered to analyze.

Increased LED Brightness for Projection Displays - Compact to High Output Systems

  • Li, Kenneth
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1433-1434
    • /
    • 2008
  • LED has gained its importance in the projection display market from very compact, micro-projectors to potentially high output, desktop systems. In both of these systems, the output levels are less than desirable. This paper describes practical recycling and multiplexing systems that provide brightness increases, and allow projectors to achieve outputs beyond its current levels.

  • PDF

A High Dose-rate Gamma Irradiation of the High Brightness Power LED (고휘도 Power LED 의 고선량 감마선 조사 특성)

  • Cho, Jai-Wan;Choi, Young-Soo;Shin, Jung-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.243-247
    • /
    • 2009
  • A Radioactive constraint of the nuclear fuel assembly irradiated by neutron during normal operation cycle of the nuclear power plant is typically on the order of about 3 kGy/h. In order to inspect nuclear fuel assembly using a VT (vision technology) system, the light such as halogen lamp is used. As the halogen lamp has lower color temperature than the sun light, the objects under halogen lamp illumination are seemed to be tinted with red. In this paper, high brightness LED is considered to be used as the light source of VT system. The high brightness LED, which is a key light source of the VT system, have been gamma irradiated at the dose rate of 4 kGy/h during two hours up to a total dose of 8 kGy. The radiation induced color-center in the LED housing cap made of plastics materials is observed.

  • PDF

Design of the High Brightness LED Driver IC with Enhanced the Output Current Control Function (출력전류 제어 기능이 향상된 고휘도 LED 구동 IC 설계)

  • Song, Ki-Nam;Han, Seok-Bung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.593-600
    • /
    • 2010
  • In this paper, High brightness LED (light-emitting diodes) driver IC (integrated circuit) using new current sensing circuit is proposed. This LED driver IC can provide a constant current with high current precision over a wide input voltage range. The proposed current-sensing circuit is composed of a cascode current sensor and a current comparator with only one reference voltage. This IC minimizes the voltage stress of the MOSFET (metal oxide semiconductor field effect transistor) from the maximum input voltage and has low power consumption and chip area by using simple-structured comparator and minimum bias current. To confirm the functioning and characteristics of our proposed LED driver IC, we designed a buck converter. The LED current ripple of the designed IC is in ${\pm}5%$ and a tolerance of the average LED current is lower than 2.43%. This shows much improved feature than the previous method. Also, protections for input voltage and operating temperature are designed to improve the reliability of the designed IC. Designed LED driver IC uses 1.0 ${\mu}m$ X-Fab. BiCMOS process parameters and electrical characteristics and functioning are verified by spectre (Cadence) simulation.

Using High Brightness LED Light Source Controller for Machine Vision (고휘도 LED를 이용한 머신비전용 조명광원 제어기 개발)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.311-318
    • /
    • 2014
  • This paper is to introduce a lighting source controller using high brightness LED to create a clear and reliable condition for an accurate measurement and testing, which is a core technology in clinical image system and mechanical automation system. This controller is designed to supply a stable power in a constant-current system by installing a high brightness LED driver, and to improve the reproducibility of brightness by using 32-bit ARM processor core, dividing brightness quantity into 256 levels, making the remote control and the external interface possible, and preventing and digitizing the brightness inaccuracy caused by errors of resistance values. This controller enables the lighting range to be wide and possible in a low lighting level compared to analog, adds the RS-485 communication function, and makes it for the users to control the on-off function and the dimming level by receiving date from an external device.

The Effect of LED Light Irradiation on Skin Injury Cure of Rat (LED 광원이 Rat의 피부 창상 치유에 미치는 영향)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Kim, Tae-Gon;Yu, Seong-Mi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1087-1092
    • /
    • 2007
  • We developed the 4-channel Light Medical Therapy Apparatus for Skin Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity and reservation. In this paper, the designed device was used to find out how high brightness LED light affects the skin injury of SD-Rat(Sprague-Dawley Rat). In the experiment, $1\;cm^2$ wounds on the skin injury of SD-Rat(Sprague-Dawley Rat) were made. Light irradiation group and none light irradiation group divided, each group was irradiated one hour a day for 14 days. In result, compared with none light irradiation group, the lower incidence of inflammation and faster recovery was shown in light irradiation group.

High Performance Control of LED Drive System for LCD Backlight (LCD 백라이트를 위한 LED 드라이브 시스템의 고성능 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.8-17
    • /
    • 2012
  • This paper proposes high performance control of light emitting diode(LED) drive system for liquid crystal display(LCD) backlight. The CCFL(cold cathode fluorescent lamp)was used to a conventional LCD backlight. Due to improvement on luminous efficiency, long life and wide color gamut, LED has gradually substituted for CCFL as backlight. The backlight using LED is necessary to use many LED. For that reason, the LED backlight is using a lot of LED driving circuits. The many LED driving circuit is generated a current deviation between LED. Eventually, it is caused brightness deviation between LED. Therefore, this paper improves the current deviation using transformer and balancing capacitor to solve this problem. Also, for accurate and uniform brightness control, this paper is applied the artificial intelligent control to a dimming control. This paper is compared with conventional system, and validity of this paper proves through that result.