• Title/Summary/Keyword: HgTe/CdTe

Search Result 99, Processing Time 0.026 seconds

A study on the electron transport properties in HgCdTe using monte carlo method (몬테칼로 방법을 사용한 HgCdTe에서의 전자 전송 특성에 관한 연구)

  • 유상동;곽계달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.40-51
    • /
    • 1998
  • Electron transport properties are investigated by Monte Carlo simulation in n-HgCdTe. The material is easily degenerated at low temperature or being slightly doped, and is characterized by small band gap and large nonparabolic factor. The degeneracy is incorporated in the Monte Carlo simulation by taking into account the electron-electron scattering and the pauli exclusion principle. In the conventional method, however, the electron-electron scattering rate was developed under the assumption of parabolic conduction band. A new formulation of the electron-electron scattering rate is develop considering the band nonparabolicity and overlap integral. The electron-electron scattering effects on the electron distribution,impact ionization coefficienty, electron temperature, drift velocity and electron energy are presented.

  • PDF

Digital X-ray Detector에 적용을 위한 Polycrystalline CdTe 구조에 따른 전기적 신호 연구

  • Kim, Jin-Seon;O, Gyeong-Min;Jo, Gyu-Seok;Song, Yong-Geun;Hong, Ju-Yeon;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.484-484
    • /
    • 2013
  • 기존 진단용 Digital X-ray Detector이 직접방식에서는 a-Se (Amorphous Selenium)이 대중화되었지만 고전압을 인가하여야한다는 점과 그로 인한 물질 자체의 Life time 감소 등 여러 단점들 때문에 기타 후보물질들로 HgI2, PbI2, PbO, CdTe, CdZnTe가 연구 되고 있다. 이러한 후보 물질들 중 본 연구에서는 PVD (Physical Vapor Deposition)방식을 이용하여 Polycrystalline CdTe 박막을 제작하고 특성 향상을 위해 유전물질을 Passive layer와 Protect layer로써 증착하였다. 또한 유전체층의 위치에 따른 특성 분석을 위해 제작된 박막은 FE-SEM (Field Emission Scanning Electron Microscope), XRD (X-ray Diffraction)을 통해 구조적인 특성을 확인하였다. 그리고 입사되는 X-ray 선량에 의해 생성되는 전기적 특성을 분석하였다, 그 결과 박막의 Grain Size는 약 $5{\mu}M$이며 (111)방향의 주 peak를 띄는 Poly CdTe형태로 증착된 것을 확인하였다. 전기적인 신호 결과 Passive layer와 Protect layer를 증착한 박막 모두 Darkcurrent가 감소된 것을 확인하였다. 또한 Sensitivity 측정 결과 Passive layer를 삽입한 경우 신호 값이 감소하였으며 Protect layer를 삽입한 경우 신호 값의 변화가 일어나지 않았다. 그러므로 Protect layer를 등착한 박막의 경우 SNR이 현저히 높아지는 결과를 낳았다.

  • PDF

MBE로 성장한 CdTe 박막의 photoconductivity

  • 임재현;허유범;류영선;전희창;현재관;강철기;강태원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.113-113
    • /
    • 1998
  • C CdTe와 HgCdTe는 광전소자나 태양전지,x 선 및 y 선 감지 소자 그리고 적외선 감지소 자로의 웅용둥으로 인하여 많은 연구가 진행되고 있다. 광전소자를 제작함에 있어서 깊은 준위나 얄은 준위에 있는 몇들은 운반자 수명에 매우 큰 영향을 미치고 있음에도 불구하고 광전도도 측정에 의한 운반자 수명 연구에 대하여는 보고된 것이 별로 없다. 이에 본 논문에서는 CdTe 시료의 광전도도를 측정하여 운반자 수명 및 깊은 준위의 위치를 알아보았다 M MBE방법을 이용하여 CdTe 기판위에 In을 도핑한 CdTe를 성장하였다. 광전도 붕괴(PCD) 측정은 300 K에서부터 400 K까지 온도를 변화시켜주면서 측정을 하였고 광원으로서 G GaP- LED를 사용하였으며 전압 신호를 읽기 위하여 Tektronix 2430A 오실로스코프를 이용하 였다 .. Fig. 1. 에서 보인바와 같이 광전도 붕괴곡선은 접선으로 나타낸 하나의 지수 함수적 붕 괴(a2exp( -t/ r 2))보다는 설선으로 나타낸 두 개의 지수함수적 붕괴(alexp( νr 1)+a2exp( -νr 2)) 가 더욱 잘 실험결과와 일치함을 알 수 있었다. 이러한 것은 과잉 전하에 대한 깊은준위를 가 지고 있는 반도체물질에서 일반적으로 관찰되는 것으로 시료가 n 형이기 때문에 소수 운반자 인 정공의 벚에 의한 것으로 생각된다 .. Fig. 2. 에서는 운반자 수명의 온도에 대한 변화를 나타 낸 것이다. 온도가 증가함에 따라 운반자 수명이 감소하는 경항올 보이고 있으며 이것올 이용 하여 딪익 활성화 에너지를 계산 하여 본 결과 0.35 eV 와 0.43 eV염을 알수 있었다.

  • PDF

High Performance of SWIR HgCdTe Photovoltaic Detector Passivated by ZnS

  • Lanh, Ngoc-Tu;An, Se-Young;Suh, Sang-Hee;Kim, Jin-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2004
  • Short wave infrared (SWIR) photovoltaic devices have been fabricated from metal organic vapour phase epitaxy (MOVPE) grown n- on p- HgCdTe films on GaAs substrates. The MOVPE grown films were processed into mesa type discrete devices with wet chemical etching employed for meas delineation and ZnS surface passivatlon. ZnS was thermally evaporated from effusion cell in an ultra high vacuum (UHV) chamber. The main features of the ZnS deposited from effusion cell in UHV chamber are low fixed surface charge density, and small hysteresis. It was found that a negative flat band voltage with -0.6 V has been obtained for Metal Insulator Semiconductor (MIS) capacitor which was evaporated at $910^{\circ}C$ for 90 min. Current-Voltage (I-V) and temperature dependence of the I-V characteristics were measured in the temperature range 80 - 300 K. The Zero bias dynamic resistance-area product ($R_{0}A$) was about $7500{\Omega}-cm^{2}$ at room temperature. The physical mechanisms that dominate dark current properties in the HgCdTe photodiodes are examined by the dependence of the $R_{0}A$ product upon reciprocal temperature. From theoretical considerations and known current expressions for thermal and tunnelling process, the device is shown to be diffusion limited up to 180 K and g-r limited at temperature below this.

Fabrication of a Large-Area $Hg_{1-x}Cd_{x}$Te Photovoltaic Infrared Detector ($Hg_{1-x}Cd_{x}$Te photovoltaic 대형 적외선 감지 소자의 제작)

  • Chung, Han;Kim, Kwan;Lee, Hee-Chul;Kim, Jae-Mook
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.2
    • /
    • pp.88-93
    • /
    • 1994
  • We fabricated a large-scale photovoltaic device for detecting-3-5$\mu$m IR, by forming of n$^{+}$-p junction in the $Hg_{1-x}Cd_{x}$Te (MCT) layer which was grown by LPE on CdTe substrate. The composition x of the MCT epitaxial layer was 0.295 and the hole concentration was 1.3${\times}10^{13}/cm^{4}$. The n$^{+}$-p junction was formed by B+ implantation at 100 keV with a does 3${\times}10^{11}/cm^{2}. The n$^{+}$ region has a circular shape with 2.68mm diameter. The vacuum-evaporated ZnS with resistivity of 2${\times}10^{4}{\Omega}$cm is used as an insulating layer over the epitaxial layer. ZnS plays the role of the anti-reflection coating transmitting more than 90% of 3~5$\mu$m IR. For ohmic contacts, gole was used for p-MCT and indium was used for n$^{+}$-MCT. The fabrication took 5 photolithographic masks and all the processing temperatures of the MCT wafer were below 90$^{\circ}C$. The R,A of the fabricated devices was 7500${\Omega}cm^{2}$. The carrier lifetime of the devices was estimated 2.5ns. The junction was linearly-graded and the concentration slope was measured to be 1.7${\times}10^{17}/{\mu}m$. the normalized detectivity in 3~5$\mu$m IR was 1${\times}10^{11}cmHz^{12}$/W, which is sufficient for real application.

  • PDF