• Title/Summary/Keyword: HgS

Search Result 1,000, Processing Time 0.027 seconds

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

Concentration of Hazardous Substances of Before/after a Decoction- In Prescription of High Frequency - (전탕 전과 후의 한약재 및 처방에 포함된 위해물질의 농도변화 -다빈도 한약 처방을 중심으로-)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.24 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • Objectives: To compare the contents of hazardous substances before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 6 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide (S02) were performed by Monier-Williams distillation method. Results : 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Socheongryong-tang (before decoction - Pb; 1.115, Cd; 0.179, As; 0.069 and Hg; 0.028, after decoction - Pb; 0.110, Cd; 0.011, As; 0.005 and Hg; 0.002), Insampaedok-san (before decoction - Pb; 1.207, Cd; 0.148, As; 0.171 and Hg; 0.026, after decoction - Pb; 0.075, Cd; 0.006, As; not detected and Hg; O.OOD, Oryung-san (before decoction - Pb; 1.955, Cd; 0.430, As; 0.063 and Hg; 0.027, after decoction - Pb; 0.083, Cd; 0.013, As; 0.006 and Hg; 0.002), Hwangryunhaedok-tang (before decoction - Pb; 1.825, Cd; 0.210, As; 0.050 and Hg; 0.009, after decoction - Pb; 0.107, Cd; 0.010, As; 0.005 and Hg; O.OOD, Bangpungtongseong-san (before decoction - Pb; 1.740, Cd; 0.162, As; 0.585 and Hg; 0.018, after decoction - Pb; 0.041, Cd; 0.006, As; 0.022 and Hg; not detected) and Oyaksungi-san (before decoction - Pb; 1.199, Cd; 0.183, As; 0.321 and Hg; 0.031, after decoction - Pb; 0.096, Cd; 0.008, As; 0.021 and Hg; 0.0004). 2. Contents (mg/kg) of sulfur dioxide (S0$_2$) before a decoction in Socheongryong-tang, Insampaedok-san, Oryung-san, Hwangryunhaedok-tang, Bangpungtongseong-san and Oyaksungi-san exhibited 3.2, 5.7, 4.5, 49.8, 7.8 and 22.4, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusions : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

The Association of Heavy Metal of Blood and Serum in the Alzheimer's Diseases

  • Lee, Ji-Yeon;Kim, Jae-Hoon;Choi, Dal-Woong;Lee, Dong-Woo;Park, Jun-Hyun;Yoon, Hye-Jung;Pyo, Hee-Soo;Kwon, Ho-Jang;Park, Kyung-Su
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • This study has attempted to establish an analysis method through validation against heavy metals in the body (Pb, Cd and Hg) using ICP-MS and Gold amalgamation and find out the relevance between heavy metal and Alzheimer's disease after analyzing the distribution of heavy metal concentration (Pb, Cd and Hg) and correlations between a control group and Alzheimer's disease group. In this study, Pb and Cd levels in the blood and serum were validation using ICP-MS. For analysis of Hg levels in the blood and serum, the gold amalgamation-based 'Direct Mercury Analyzer' has been used. According to an analysis on the heavy metal concentration (Pb, Cd and Hg concentration) in the blood, Cd concentration was high in the Alzheimer's disease group. In the serum, on the contrary, Pb and Hg were high in the Alzheimer's disease group. For analysis of correlations between heavy metal levels in the blood and serum and Alzheimer's disease, t-test has been performed. Even though correlations were observed between the blood lead levels and Alzheimer's disease, they were statistically insignificant because the concentration was higher in a control group. No significance was found in Cd and Hg. In the serum, on the other hand, no statistical significance was found between the heavy metal (Pb, Cd and Hg) and Alzheimer's disease. In this study, no statistical significance was observed between heavy metal and decrease in cognitive intelligence. However, it appears that a further study needs to be performed because the results of the conventional studies were inconsistent.

A Study on the long-term Hemodialysis patient중s hypotension and preventation from Blood loss in coil during the Hemodialysis (장기혈액투석환자의 투석중 혈압하강과 Coil내 혈액손실 방지를 위한 기초조사)

  • 박순옥
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.83-104
    • /
    • 1981
  • Hemodialysis is essential treatment for the chronic renal failure patient's long-term cure and for the patient management before and after kidney transplantation. It sustains the endstage renal failure patient's life which didn't get well despite strict regimen and furthermore it becomes an essential treatment to maintain civil life. Bursing implementation in hemodialysis may affect the significant effect on patient's life. The purpose of this study was to obtain the basic data to solve the hypotension problem encountable to patient and the blood loss problem affecting hemodialysis patient'a anemic states by incomplete rinsing of blood in coil through all process of hemodialysis. The subjects for this study were 44 patients treated hemodialysis 691 times in the hemodialysis unit, The .data was collected at Gang Nam 51. Mary's Hospital from January 1, 1981 to April 30, 1981 by using the direct observation method and the clinical laboratory test for laboratory data and body weight and was analysed by the use of analysis of Chi-square, t-test and anlysis of varience. The results obtained an follows; A. On clinical laboratory data and other data by dialysis Procedure. The average initial body weight was 2.37 ± 0.97kg, and average body weight after every dialysis was 2.33 ± 0.9kg. The subject's average hemoglobin was 7.05±1.93gm/dl and average hematocrit was 20.84± 3.82%. Average initial blood pressure was 174.03±23,75mmHg and after dialysis was 158.45±25.08mmHg. The subject's average blood ion due to blood sample for laboratory data was 32.78±13.49cc/ month. The subject's average blood replacement for blood complementation was 1.31 ±0.88 pint/ month for every patient. B. On the hypotensive state and the coping approaches occurrence rate of hypotension was 28.08%. It was 194 cases among 691 times. 1. In degrees of initial blood pressure, the most 36.6% was in the group of 150-179mmHg, and in degrees of hypotension during dialysis, the most 28.9% in the group of 40-50mmHg, especially if the initial blood pressure was under 180mmHg, 59.8% clinical symptoms appeared in the group of“above 20mmHg of hypotension”. If initial blood pressure was above 180mmHg, 34.2% of clinical symptoms were appeared in the group of“above 40mmHg of hypotension”. These tendencies showed the higher initial blood pressure and the stronger degree of hypotension, these results showed statistically singificant differences. (P=0.0000) 2. Of the occuring times of hypotension,“after 3 hrs”were 29.4%, the longer the dialyzing procedure, the stronger degree of hypotension ann these showed statistically significant differences. (P=0.0142). 3. Of the dispersion of symptoms observed, sweat and flush were 43.3%, and Yawning, and dizziness 37.6%. These were the important symptoms implying hypotension during hemodialysis accordingly. Strages of procedures in coping with hypotension were as follows ; 45.9% were recovered by reducing the blood flow rate from 200cc/min to 1 00cc/min, and by reducing venous pressure to 0-30mmHg. 33.51% were recovered by controling (adjusting) blood flow rate and by infusion of 300cc of 0,9% Normal saline. 4.1% were recovered by infusion of over 300cc of 0.9% normal saline. 3.6% by substituting Nor-epinephiine, 5.7% by substituting blood transfusion, and 7,2% by substituting Albumin were recovered. And the stronger the degree of symptoms observed in hypotention, the more the treatments required for recovery and these showed statistically significant differences (P=0.0000). C. On the effects of the changes of blood pressure and osmolality by albumin and hemofiltration. 1. Changes of blood pressure in the group which didn't required treatment in hypotension and the group required treatment, were averaged 21.5mmHg and 44.82mmHg. So the difference in the latter was bigger than the former and these showed statistically significant difference (P=0.002). On the changes of osmolality, average mean were 12.65mOsm, and 17.57mOsm. So the difference was bigger in the latter than in the former but these not showed statistically significance (P=0.323). 2. Changes of blood pressure in the group infused albumin and in the group didn't required treatment in hypotension, were averaged 30mmHg and 21.5mmHg. So there was no significant differences and it showed no statistical significance (P=0.503). Changes of osmolality were averaged 5.63mOsm and 12.65mOsm. So the difference was smaller in the former but these was no stitistical significance (P=0.287). Changes of blood pressure in the group infused Albumin and in the group required treatment in hypotension were averaged 30mmHg and 44.82mmHg. So the difference was smaller in the former but there is no significant difference (P=0.061). Changes of osmolality were averaged 8.63mOsm, and 17.59mOsm. So the difference were smaller in the former but these not showed statistically significance (P=0.093). 3. Changes of blood pressure in the group iutplemented hemofiltration and in the Uoup didn't required treatment in hypotension were averaged 22mmHg and 21.5mmHg. So there was no significant differences and also these showed no statistical significance (P=0.320). Changes of osmolality were averaged 0.4mOsm and 12.65mOsm. So the difference was smaller in the former but these not showed statistical significance(P=0.199). Changes of blood pressure in the group implemented hemofiltration and in the group required treatment in hypotension were averaged 22mmHg and 44.82mmHg. So the difference was smatter in the former and these showed statistically significant differences (P=0.035). Changes of osmolality were averaged 0.4mOsm and 17.59mOsm. So the difference was smaller in the former but these not showed statistical significance (P=0.086). D. On the changes of body weight, and blood pressure, between the group of hemofiltration and hemodialysis. 1, Changes of body weight in the group implemented hemofiltration and hemodialysis were averaged 3.340 and 3.320. So there was no significant differences and these showed no statistically significant difference, (P=0.185) but standard deviation of body weight averaged in comparison with standard difference of body weight was statistically significant difference (P=0.0000). Change of blood Pressure in the group implemented hemofiltration and hemodialysis were averaged 17.81mmHg and 19.47mmHg. So there was no significant differences and these showed no statistically significant difference (P=0.119), But in comparison with standard deviation about difference of blood pressure was statistically significant difference. (P=0.0000). E. On the blood infusion method in coil after hemodialysis and residual blood losing method in coil. 1, On comparing and analysing Hct of residual blood in coil by factors influencing blood infusion method. Infusion method of saline 200cc reduced residual blood in coil after the quantitative comparison of Saline Occ, 50cc, 100cc, 200cc and the differences showed statistical significance (p < 0.001). Shaking Coil method reduced residual blood in Coil in comparison of Shaking Coil method and Non-Shaking Coil method this showed statistically significant difference (P < 0.05). Adjusting pressure in Coil at OmmHg method reduced residual blood in Coil in comparison of adjusting pressure in Coil at OmmHg and 200mmHg, and this showed statistically significant difference (P < 0.001). 2. Comparing blood infusion method divided into 10 methods in Coil with every factor respectively, there was seldom difference in group of choosing Saline 100cc infusion between Coil at OmmHg. The measured quantity of blood loss was averaged 13.49cc. Shaking Coil method in case of choosing saline 50cc infusion while adjusting pressure in coil at OmmHg was the most effective to reduce residual blood. The measured quantity of blood loss was averaged 15.18cc.

  • PDF

Association of Metabolic syndrome, Metabolic syndrome score and Pulse pressure in Korean Adults: Korea National Health and Nutrition Survey, 2012 (한국 성인에서 대사증후군 및 Metabolic syndrome score와 맥압의 관련성-2012 국민건강영양조사에 근거하여)

  • Park, Sun-Young;Yoon, Hyun;Oh, Hye-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5660-5667
    • /
    • 2014
  • The aim of this study was to assess the association of metabolic syndrome, metabolic syndrome score (MSS) and pulse pressure (PP) in Korean adults. The study subjects were Korean adults 20 years or older (n=5,889) who participated in the Korea National Health and Nutrition Examination Survey 2012. After adjusting for factors, such as year and gender and BMI, the mean PP increased with increasing MSS (MSS 0, $41.30{\pm}0.34mmHg$ and MSS 1, $42.16{\pm}0.31mmHg$ and MSS 2, $44.73{\pm}0.34mmHg$ and MSS, 3, $46.46{\pm}0.42mmHg$ and MSS 4, $48.62{\pm}0.58mmHg$ and MSS 5, $53.50{\pm}1.05mmHg$), and the mean PP for metabolic syndrome($47.25{\pm}0.34mmHg$) increased in comparison to Non-Metabolic syndrome ($42.77{\pm}0.19mmHg$). When logistic regression analysis was performed, the odds ratio (OR) of Hyper-PP (61> PP) for MSS 0 was 4.49 in MSS 1 (95% confidence interval[CI], 2.68-7.57) and 8.01 in MSS 2 (95% CI, 4.77-13.47) and 11.37 in MSS 3 (95% CI, 6.67-19.35) and 19.69 in MSS 4 (95% CI, 11.20-34.60) and 34.07 in MSS 5 (95% CI, 17.44-66.52), metabolic syndrome was associated with an increased Hyper-PP(OR 4.6, 95% CI, 2.0-10.4). Conclusion. These results suggest that an increase in MSS or metabolic syndrome might increase the pulse pressure.

Agreement and Digit Preference of Blood Pressure Measurements Between pairs of Random-Zero Sphygmomanometer, Digit Automatic Device and Regular Mercury Sphygmomanometer on Hypertensive Urban Young African-American Men (도시지역 고혈압을 가진 젊은 흑인 남성들의 Random-Zero Sphygmomanometer, Digit Automatic Device 와 Regular Mercury Spygmomanometer 사이의 혈압측정 방법에 의한 일치도와 점(숫자)선호도)

  • Park, Kyung-Min
    • Research in Community and Public Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.170-177
    • /
    • 1996
  • 신체의 활력을 측정하는 혈압은 다른 어느 측정치보다 변동이 심하고 정상적으로 변할 수 있는 생리적 현상이어서 정확하게 측정하기란 쉽지 않다. 1mmHg 차이의 혈압일지라도, 특히 큰 집단일 경우, 연구목적에서 그 결과를 크게 왜곡 시킬 수 있다. (Wright & dore, 1970). 혈압 측정에는 직접적 방법과 간접적 방법이 있다. 이 중 간접적 방법은 임상분야와 연구분야에서 실제로 넓게 사용되고 있을 분만 아니라 신체로의 직접적 침투하는 방법도 아니고 가격 또한 비싸지 않다. 그러나, 간접적 측정 방법은 혈압에 영향을 끼치는 많은 요인들인 관찰자 편견, 확장기음의 청취음 선택, 관찰자와 환자 사이의 상호관계 때문에 방법론적으로 문제제기가 되기도 한다. 이런 요인을 최소화하기 위하여 가장 타당도가 높은 측정도구의 선택이 필요하다. 도시지역의(Ease Baltimore) 고혈압을 가진 젊은 흑인 남성(연령별/성별/종속별/거주지역) 중 수축기 혈압이 140mmHg 이고 확장기 혈압이 90mmHg인 사람, 또는 확장기 혈압이 90mmHg인 사람, 또는 혈압하강제를 먹고 있는 사람 200명을 대상으로 훈련받은 community health worker(CHW)에 의해 Random-Zero Sphygmdmanometer(RZS)와 Digit Automatic Device(DAD)로 혈압을 측정하게 하였다. 이 중 36명을 무작위 추출하여 regular Mercury Sphygmdmanometer (RMS)로 혈압을 측정하게 했다. Bland 와 Altman에 의해 제기된 두측정값의 차이에 대한 scattergram(일치도 검증법)과 AAMI(Association for the Advancement of Medical Instrument) 기준, BHS 기준, Central Tendency와 숫자선호도로 검증되었다. AAMI와 BHS 기준에 의하면 확장기 혈압에서 RZS와 DAD의 일치도와 평균을 중심으로 더 넓게 퍼져있어 낮은 일치도를 보였으며 또 DAD와 RMS의 혈압치는 숫자 선호도를 볼 수 있는데 특히 RMS는 더 뚜렷하게 나타났는데 확장기 혈압의 최빈치(30.6)는 100mmHg이었다. 혈압치들이 가장 가까이 "0"점으로 치우쳐져 있었다. RZS의 Central tendency는 DAD와 RMS보다 뚜렷하였다. 결론적으로 RZS는 이 연구목적으로 가장 적절함을 보여준다.

  • PDF

Voltammetric Assay of Mercury Ion in Fish Kidneys

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • Voltammetric analysis of mercury ions was developed using paste electrodes (PEs) with DNA and carbon nanotube mixed electrodes. The optimized analytical results of the cyclic voltammetry (CV) of the $1{\sim}14ng\;L^{-1}Hg(II)$ concentration and the square wave (SW) stripping voltammetry of the $1{\sim}12ng\;L^{-1}Hg(II)$ working range within an accumulation time of 400 seconds were obtained in 0.1 M $NH_4H_2PO_4$ electrolyte solutions of pH 4.0. For the relative standard deviations of the $1ng\;L^{-1}Hg(II)$, which were observed at 0.078% (n = 15) at the optimum conditions, the low detection limit (S/N) was pegged at $0.2ng\;L^{-1}(7.37{\times}10^{-13}M)$ for Hg(II). The results can be applied to assays in biological fish kidneys and wastewater samples.

AIN Microstructure Evalution through Hg-porosimetry (수은침투법을 이용한 AIN 미세구조연구)

  • Lee, Hae-Weon;Yoon, Bok-Gyu;Hong, Kug-Sun
    • Analytical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.217-222
    • /
    • 1992
  • An attempt was made to analyze green microstructure of AIN samples prepared by slip casting and dry pressing through Hg-porosimetry. Slip cast samples with narrow pore size distribation and high packing density showed higher sinterability and homogeneous distribution of second phase(s). Hg-porosimetry is and effective way to determine pore structure if "ink bottle" phenomenon does not occur. A comparison study with porosity measurement by quantitative microscopy showed that the effectiveness of Hg-porosimetry measurement could be extended to higher sintered density as long as pores remained open.

  • PDF

A Calculation of C-V Characteristics for ${Hg}_{1-x}{Cd}_{x}$Te MIS Device (${Hg}_{1-x}{Cd}_{x}$Te MIS 소자의 C-V 특성 계산)

  • 이상돈;김봉흡;강형부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.420-431
    • /
    • 1994
  • The HgCdTe material, which is II-VI compound semiconductor, is important materials for the fabrication of the infrared detectros. To suggest the model of accurate MIS C-V calculation for narrow band gap semiconductors such as HgCdTe, non-parabolicity from k.p theory and degeneracy effect are considered. And partially ionized effect and compensation effect which are material's properties are also considerd. Especially, degenerated material C-V characteristics from Fermi-Dirac statistics and exact charge theory are presented to get more accurate analysis of the experimental results. Also the comparison with calculation results between the general MIS theory from Boltzmann appoximation method and this model which is considered the narrow band gap semiconductor properties, show that this model is more useful theory to determination of accurate low and high frequency C-V characteristics.

  • PDF