• Title/Summary/Keyword: HgS

Search Result 1,005, Processing Time 0.031 seconds

Blood Pressure Simulation using an Arterial Pressure-volume Model

  • Yoon, Sang-Hwa;Kim, Jae-Hyung;Ye, Soo-Young;Kim, Cheol-Han;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.1
    • /
    • pp.38-43
    • /
    • 2008
  • Using an arterial pressure-volume (APV) model, we performed an analysis of the conventional blood pressure estimation method using an oscillometric sphygmomanometer with computer simulation. Traditionally, the maximum amplitude algorithm (MAA) has been applied to the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected by the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPF) circuitry. Experimental errors result from these effects when estimating blood pressure. To determine an algorithm independent of the influence of waveform shapes and parameters of HPF, the volume oscillation of the APV model and the phase shift of the oscillation with fast Fourier transform (FFT) were tested while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg/s). The phase shift between ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were obtained from simulations performed on two different arterial blood pressure waveforms and one hyperthermia waveform.

Effect of fungicides to mycelial growth of some wood destroying fungi (수종목재부후균(數種木材腐朽菌)의 균사발육(菌糸發育)에 미치는 살균제(殺菌劑)의 영향(影響))

  • Chung, Dai Kyo
    • Journal of Korean Society of Forest Science
    • /
    • v.4 no.1
    • /
    • pp.14-16
    • /
    • 1965
  • (1) The sterilizing effects of NaF, $CuSO_4$, $CuCO_3$, $HgCl_2$, $ZnSO_4$, and coaltar creosote on the mycelial growth of Irpex consors Berk. Polystictus versicolor L. Fr, Polystictus versicalor L. var. nigricans, and Schizophyllum commune Fr. Were studied. (2) The range of minimum density of the fungicides to check the growth of four fungi mentioned above was as follows; NaF 0.15~0.25(%) $CuSO_4$ 0.20~0.35(%) $CuCO_3$ 0.40~0.50(%) $HgCl_2$ 0.05(%) $ZnSO_4$ 0.40~0.45(%) Creosote 0.10~0.15(%) Of the fungicides tested, $HgCl_2$ was most effective in fungicidal effects, and Creosote, NaF, $CuSO_4$, $ZnSO_4$, $CuCO_3$, followed. The order of resistance of the fungi to the fungicides was as follows: S. Commune Fr. P. Versicalor L. var.nigricans I. Consors Berk P. Versicalor L. Fr. (3) The fungicides were added to the pepton-agor culture medium at the concentration between 0.01 and 0.5%, and the medium was filled into 9cm petridshes. Two square millimeter agar blocks prepared separately from the fungi Contained agar were placed in the middle of the Petri-dishes, in cubated six days at $26^{\circ}C$. Diameter of biggest Colonies were measured.

  • PDF

1,8-Naphthyridine Modified Naphthalimide Derivative: Ratiometric and Selective Sensor for Hg2+ in Organic Aqueous Solution

  • Shi, Yong Gang;Duan, Yu Lian;Chen, Jian Hua;Wu, Xiang Hua;Zhou, Ying;Zhang, Jun Feng
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.63-67
    • /
    • 2013
  • A bottom-modified (4-position) naphthalimide derivative 1 with 1,8-naphthyridine as binding site has been designed and synthesized. Compound 1 is the first 1,8-naphthyridine-modified naphthalimide-based sensor that can detect $Hg^{2+}$ selectively with respect to ratiometric fluorescent change and blue shift in organic aqueous solution. The Job's plot and FAB mass indicate that 1 formed a 1:1 complex with $Hg^{2+}$. A top-modified naphthalimide derivative 2 with 1,8-naphthyridin as binding site has also been synthesized for comparison.

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy (관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석)

  • Kim, Byung-Tae;Koong, Sung-Soo;Bom, Hee-Seung;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

A Study on Handiwork Technique of Filigree Artifacts Excavated from Neungsan-ri Temple Site in Buyeo, Korea (부여 능산리사지 출토 누금세공 유물의 제작기술 연구)

  • Lee, Sun-Myung;Kung, Seung-Nam;Kim, Yeon-Mi
    • Journal of Conservation Science
    • /
    • v.26 no.1
    • /
    • pp.13-24
    • /
    • 2010
  • This study examined each handiwork method of 4 filigree artifacts from Neungsan-ri temple site in Buyeo, Korea through material characteristic and microstructure analysis. As a result, it was indicated that all of the artifacts have comparatively higher purity than 22.7K and some of filigree artifacts showed that gold is alloyed with silver at a certain ratio. Gold thread that decorates surface showed thickness of 0.2~0.8mm and displayed various forms of section. Gold granule indicated that 2 or 3 granules are adhered together and they are 0.3~0.8mm in diameter. Trace of soldering was observed from gold thread and gold granule joints on surface and it confirmed a possibility of being soldering using gold solder through componential analysis. Also, it reveals a surface decorated with pigments such as cinnabar(HgS) and black.

Preparation and Crystal Structures of Silver(I), Mercury(II), and Lead(II) Complexes of Oxathia-Tribenzo-Macrocycles

  • Siewe, Arlette Deukam;Ju, Huiyeong;Lee, Shim Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.725-730
    • /
    • 2013
  • An investigation of the coordination behavior of sulfur-containing mixed-donor tribenzo-macrocycles $L^1-L^3$ ($L^1$: 20-membered $O_3S_2$, $L^2$: 20-membered $O_2S_3$, and $L^3$: 23-membered $O_4S_2$) with $d^{10}$-metal ($Ag^+$, $Hg^{2+}$, and $Pb^{2+}$) salts is reported. The X-ray structures of five complexes (1-5) with different structural types and stoichiometries, including mono- to dinuclear species have been determined. Reactions of $L^2$ and $L^3$ with the silver(I) salts ($PF_6{^-}$ and $SCN^-$) afforded two dinuclear 2:2 (metal-to-ligand) complexes with different arrangements: a sandwich-type cyclic dinuclear complex $[Ag_2(L^2)_2](PF_6)_2{\cdot}3CH_2Cl_2$ (1) and a linear dinuclear complex $[Ag_2(L^3)_2(SCN)_2]$ (2), in which two monosilver(I) complex units are linked by an Ag-Ag contact. Reactions of $L^1$ and $L^2$ with mercury(II) salts ($SCN^-$ and $Cl^-$) gave a mononuclear 1:1 complexes $[Hg(L^1)(SCN)_2]$ (3) and $[Hg(L^2)Cl_2]$ (4) with anion coordination in both cases. $L^2$ reacts with lead(II) perchlorate to yield a mononuclear sandwich-type complex $[Pb(L^2)_2(ClO_4)_2]$ (5), giving an overall metal coordination geometry of eight with a square antiprism arrangement. From these results, the effects of the donor variation and the anioncoordination ability on the resulting topologies of the soft metal complexes are discussed.

Feasibility as radiation detectors of Flexible ITO film fabricated by roll-to-roll sputtering (롤-투-롤 스퍼터링으로 제작된 Flexible ITO Film의 방사선검출기 적용가능성 연구)

  • Kim, Sung-Hun;Lee, S.H.;Jeon, S.P.;Park, G.U.;Heo, E.S.;Sung, Han-Kyu;Park, J.G.;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.374-374
    • /
    • 2010
  • 본 연구는 Roll-to-Roll Sputtering 장비를 사용하여 제작된 Flexible ITO electrode 필름의 방사선 검출기로의 적용가능성을 알아보기 위해 기존의 Glass ITO electrode의 전기적 특성을 비교 평가하였다. 본 연구는 Flexible ITO electrode와 Glass ITO electrode을 하부전극으로 형성하고, 최근에 X-ray 변환체로 활발히 연구되고 있는 Powder 형태의 반도체물질인 HgI2 와 PbI2를 Binder와 일정한 비율로 혼합하여 3-Rolls-Miller를 사용하여 Powder를 일정한 미세크기로 만들고, 대면적 제작이 용이한 Screen-Printing method을 이용하여 시편을 제작하였다. 제작된 필름은 하부전극의 종류에 따른 X-ray 입사 후의 전기적신호의 차이를 측정하고, HgI2와 PbI2 중 Flexible ITO electrode와 더욱 효율적으로 반응하여 기존의 Glass ITO electrode를 대체할 수 있는 전극을 발견하여 진단용 의료영상의 왜곡 현상을 제거할 수 있는 Flexible 방사선 검출기의 제작의 초석을 제공하는 연구를 목적으로 한다. SEM(Scanning Electron Microscope) 통하여 반도체 물질의 결정구조와 크기를 알아보았고, 하부 전극의 종류에 따른 전기적 신호검출을 위해 제작된 필름의 암전류(Dark current) 와 민감도(Sensitivity)를 측정한 후, SNR (Signal -to- Noise)을 계산하여 평가하였다.

  • PDF

Clinical Application of Balloon Valvuloplasty in a Boxer Dog with Subaortic Stenosis (대동맥 판막하 협착증에 이환된 박서견의 풍선 확장술 적용예)

  • Choi, Ran;Nam, So-Jeong;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.160-165
    • /
    • 2009
  • A 4-month-old intact male Boxer dog(9 kg of body weight) was presented with the primary complaints of heart murmur and exercise intolerance. Diagnostic studies revealed severe subaortic stenosis. Since the pressure gradient(PG) in stenotic aortic valve area was higher than ${\sim}120mmHg$(5.4 m/s of peak velocity), the dog was underwent balloon valvuloplasty. With this procedure, the peak aortic velocity was reduced to 3.9 m/s(${\sim}60mmHg$ of PG) and the clinical condition of dog was markedly improved. Periodic re-evaluations performed at monthly interval revealed no further deterioration. This is the first case report of subaortic stenosis treated by non-surgical palliative balloon valvuloplasty in Korea.