• 제목/요약/키워드: Hemostatic solution

검색결과 6건 처리시간 0.025초

치과용 지혈제가 상아질 투과도에 미치는 영향 (THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY)

  • 김종현;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

Tourniquet-Free Hand Surgery Using the One-per-Mil Tumescent Technique

  • Prasetyono, Theddeus O.H.
    • Archives of Plastic Surgery
    • /
    • 제40권2호
    • /
    • pp.129-133
    • /
    • 2013
  • Background A pneumatic tourniquet is generally used to achieve a bloodless operation field in hand surgery. However, this has changed with tumescent solution-based wide-awake surgery. This study is a preliminary prospective case series study to elaborate the formula and indications of the tumescent technique in hand surgery without a tourniquet. Methods Seven patients (age range, 4 months to 37 years) underwent hand or upper extremity surgery for conditions such as nerve palsy, electric burn defect, fingertip injury, contracture, constriction ring syndrome, or acrosyndactyly. A "one-per-mil" tumescent solution (epinephrine 1:1,000,000+20 mg lidocaine/50 mL saline) was used to create a bloodless operating field without a tourniquet. Observation was performed to document the amount of solution injected, the operation field clarity, and the postoperative pain. Results The "one per mil" epinephrine solution showed an effective hemostatic effect. The tumescent technique resulted in an almost bloodless operation field in the tendon and in the constriction ring syndrome surgeries, minimal bleeding in the flap and contracture release surgeries, and acceptable bleeding in acrosyndactyly surgery. The amount of solution injected ranged from 5.3 to 60 mL. No patient expressed significant postoperative pain. Flap surgeries showed mixed results. One flap was lost, while the others survived. Conclusions Epinephrine 1:1,000,000 in saline solution is a potential replacement for a tourniquet in hand surgery. Further studies are needed to delineate its safety for flap survival.

Comparison of hemostatic efficacy and cytotoxicity of three ferric subsulfate- and chitosan-based styptics in different formulations using a rat tail bleeding model

  • Byun, Jae-Young;Lee, Soojung;Lee, Jeong Ik;Yoon, Hun-Young
    • 대한수의학회지
    • /
    • 제58권3호
    • /
    • pp.119-124
    • /
    • 2018
  • This study was conducted to compare the hemostatic efficacy of three ferric subsulfate- and chitosan-based styptics as a powder and a gel containing ferric subsulfate and chitosan (FSC-PO and FSC-G, respectively) and a soaked pad containing ferric subsulfate and lidocaine (FSL-SP) using a rat tail bleeding model. The cytotoxicity of the styptics against L-929 mouse fibroblasts was also evaluated using a cell counting kit-8 assay. Four groups of 10 rats each were assigned to the three different styptics and a non-treated control groups. Rat tail tips were transected, after which styptics were applied with pressure. The wounds were observed for hemostasis for 3 min, then irrigated with saline to check for recurrent hemorrhage. L-929 mouse fibroblasts were exposed to extracts of the styptics (100 mg/mL) and their dilutions (1:10, 1:100, and 1:1,000). FSC-PO and FSC-G more effectively controlled initial hemorrhage than FSL-SP (p = 0.033). Additionally, FSC-PO and FSC-G more effectively maintained hemostasis than the control group (p = 0.02 and p < 0.01, respectively). However, all styptics showed enhanced cytotoxicity against L-929 cells in a dose-dependent manner. Therefore, although FSC-PO and FSC-G would be recommended to control hemorrhage, the benefits of styptics must be balanced against the clinical significance of their cytotoxicity.

지혈제 오염이 콤포머의 전단결합강도에 미치는 영향 (THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER)

  • 허정무;곽주석;이황;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

심폐바이패스시 혈액응고체계 변화의 혈전탄성검사 분석 - 단일 저용량 아프로티닌 투여 효과 분석 - (Thromboelastographic Analysis of the Coagulation System During Cardiopulmonary Bypass -Analysis of the Effect of Low-Dose Aprotinin)

  • 김관민;박계현
    • Journal of Chest Surgery
    • /
    • 제30권7호
    • /
    • pp.677-685
    • /
    • 1997
  • 혈전탄성검사(혈전탄성검사, thomboelastography)는 혈전 생성 전 과정에 대한 신속한 정보를 제공해 주는 유용한 측정 방법 중의 하나이며, 많은 수술 과정에서 발생하는 혈액응고 장애의 진단을 용이하게 함으로써 적절한 치료를 가능케 한다. 최근, 단백질분해효소 억제제인 아프로티닌에 의해 심폐바이패스 후의 혈액응고 장애에 의한 출혈 문제가 많이 해결되었지만,그 지혈 작용 기전은 아직 정확히 알려져 있지 않다. 이 연구 는 개심술을 시행 받은 환자들에서 아프로티닌이 심폐바이패스에 의한 혈액응고 체계 변화에 미치는 효과를 혈전탄성검사로 분석하기위하여 시행하였다 20세 이상 성인 개심슬 환자 40명을 2개의 군으로 나누어 시행하였다. 대조군(남 10명, 여8명, 평균연령 53.4세)은 심폐기 충전액에 아프로티닌을 투여하지 않았고, 아프로티닌군(남 14명, 여 8명, 평균연령 50.8세) 은 심폐기 충전액에 아프로티닌 2백만 KIU(kallikrein inhibition unit)를 투여하였다. 이 들을 대상으로, 심폐바 이패스 전, 후( 프로타민에 의한 헤파린 효과 중화 30분 후)에 혈전탄성검사와, 활성응고시간, 프로트롬빈시 간, 활성부분트롬보플라스틴시간, 혈소 \ulcorner수, 섬유소원과 섬유소용해물질 농도 등 일반적인 혈액응고 검사들 을 시행하였다. 일반적인 혈액응고 검사상에서는, 두 군간에는 섬유소용해물질이 대조군에서 심폐바이패스 후 아프로티닌 군 보다 의미 있게 증가한 것(p<0.05)을 제외하고는 차이가 발견되지 않았다. 혈전탄성검사에서는 혈전형성 시간(K)과 $알파각(\alpha^{\circ})이$ 두 군 모두에서 심폐바이패스 후에 각각 증가 및 감소하였으나(p<0.05), 섬유소용해 지수(LYS60)는 차이가 없었다. 아프로티닌군에서는, 반응시간(R)은 심폐바이패스 후에 감소하였으나(p<0.09) 혈전강도최대치(h4A)는 변화가 없었다. 반면 대조군에서는, 반응시간은 변화가 없었으나 혈전강도최대치는 의미 있게 감소하였다(p<0.05). . 이상의 결과로부터, 심폐바이패스 시 혈액응고 체계의 주된 변화는 혈소판 기능 저하에 의한 혈전 강도의 저하이고, 과도한 섬유소용해의 증가는 일어나지 않으며, 아프로티닌은 심폐바이패스 후의 혈액응고 체계에 서 초기에는 항혈액응고 작용을 갖지만, 심폐바이패스에 의한 혈소판 기능의 저하를 억제하여, 일단.혈전이 형성되기 시작하면 혈전강도를 심폐바이패스 전 상태로 유지하는 효과를 갖는다고 \ulcorner각된다.

  • PDF