• Title/Summary/Keyword: Hemostatic solution

Search Result 6, Processing Time 0.021 seconds

THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY (치과용 지혈제가 상아질 투과도에 미치는 영향)

  • Kim, Chong-Hyun;Shim, June-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

Tourniquet-Free Hand Surgery Using the One-per-Mil Tumescent Technique

  • Prasetyono, Theddeus O.H.
    • Archives of Plastic Surgery
    • /
    • v.40 no.2
    • /
    • pp.129-133
    • /
    • 2013
  • Background A pneumatic tourniquet is generally used to achieve a bloodless operation field in hand surgery. However, this has changed with tumescent solution-based wide-awake surgery. This study is a preliminary prospective case series study to elaborate the formula and indications of the tumescent technique in hand surgery without a tourniquet. Methods Seven patients (age range, 4 months to 37 years) underwent hand or upper extremity surgery for conditions such as nerve palsy, electric burn defect, fingertip injury, contracture, constriction ring syndrome, or acrosyndactyly. A "one-per-mil" tumescent solution (epinephrine 1:1,000,000+20 mg lidocaine/50 mL saline) was used to create a bloodless operating field without a tourniquet. Observation was performed to document the amount of solution injected, the operation field clarity, and the postoperative pain. Results The "one per mil" epinephrine solution showed an effective hemostatic effect. The tumescent technique resulted in an almost bloodless operation field in the tendon and in the constriction ring syndrome surgeries, minimal bleeding in the flap and contracture release surgeries, and acceptable bleeding in acrosyndactyly surgery. The amount of solution injected ranged from 5.3 to 60 mL. No patient expressed significant postoperative pain. Flap surgeries showed mixed results. One flap was lost, while the others survived. Conclusions Epinephrine 1:1,000,000 in saline solution is a potential replacement for a tourniquet in hand surgery. Further studies are needed to delineate its safety for flap survival.

Comparison of hemostatic efficacy and cytotoxicity of three ferric subsulfate- and chitosan-based styptics in different formulations using a rat tail bleeding model

  • Byun, Jae-Young;Lee, Soojung;Lee, Jeong Ik;Yoon, Hun-Young
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.119-124
    • /
    • 2018
  • This study was conducted to compare the hemostatic efficacy of three ferric subsulfate- and chitosan-based styptics as a powder and a gel containing ferric subsulfate and chitosan (FSC-PO and FSC-G, respectively) and a soaked pad containing ferric subsulfate and lidocaine (FSL-SP) using a rat tail bleeding model. The cytotoxicity of the styptics against L-929 mouse fibroblasts was also evaluated using a cell counting kit-8 assay. Four groups of 10 rats each were assigned to the three different styptics and a non-treated control groups. Rat tail tips were transected, after which styptics were applied with pressure. The wounds were observed for hemostasis for 3 min, then irrigated with saline to check for recurrent hemorrhage. L-929 mouse fibroblasts were exposed to extracts of the styptics (100 mg/mL) and their dilutions (1:10, 1:100, and 1:1,000). FSC-PO and FSC-G more effectively controlled initial hemorrhage than FSL-SP (p = 0.033). Additionally, FSC-PO and FSC-G more effectively maintained hemostasis than the control group (p = 0.02 and p < 0.01, respectively). However, all styptics showed enhanced cytotoxicity against L-929 cells in a dose-dependent manner. Therefore, although FSC-PO and FSC-G would be recommended to control hemorrhage, the benefits of styptics must be balanced against the clinical significance of their cytotoxicity.

THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER (지혈제 오염이 콤포머의 전단결합강도에 미치는 영향)

  • Heo, Jeong-Moo;Kwak, Ju-Seog;Lee, Hwang;Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

Thromboelastographic Analysis of the Coagulation System During Cardiopulmonary Bypass -Analysis of the Effect of Low-Dose Aprotinin (심폐바이패스시 혈액응고체계 변화의 혈전탄성검사 분석 - 단일 저용량 아프로티닌 투여 효과 분석 -)

  • 김관민;박계현
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.677-685
    • /
    • 1997
  • Thromboelastography(TEG) is the unique measure that gives rapid information about the whole clotting process. Simplifying the diagnosis of coagulopathy during operations, TEG can provide an adequate therapy for postoperative bleeding. Remarkable improvement in hemostasis after cardiopulmonary bypass(CPB) has been achieved by the treatment with proteinase inhibitor aprotinin, but the hemostatic mechanism of aprotinin during CPB is still unclear. This study was designed to evaluate the effects of aprotinin on coagulation system during CPB by using TEG. Forty patients who underwent CPB were divided into two groups: aprotinin(2u 106 kallikrein inhibition units, as a single dose into the cardiopulmonary bypass priming solution) treatment group(male 14, female 8, mean age=50.Byears) and no aprotinin treatment(control) group(male 10, female 8, mean age=53.4 years). TEG, activated clotting time, prothrombin time, activated partial thromboplastin time, platelet counts, fibrinogen an (ibrinogen degradation product(FDP) concentrations were checked before and after CPB(30 minutes after neutralization of heparin effect by protamine sulfate). There was no significant difference in other conventional coagulation tests of two groups except postcardiopulmonary bypass FDP concentration in control group, which was significantly increased compared to that in aprotinin group(p<0.05). In TEG variables of both groups, clot formation time(K) and alpha $angle(\alpha^{\circ})$ were significantly increased and decreased, respectively, after CPB(p<0.05), but fibrinolytic index(LYS60) was not changed during CPB. In aprotinin group, reaction time(R) was decreased significantly after CPB(p<0.05) but maximum amplitude(MA) was not changed(p>0.05). On the contrary, R was not changed markedly but MA was decreased significantly in control group after CPB(p<0.05). This result shows that main change in coagulation system during CPB is not hyperfibrinolysis but cecrease in clot strength by platelet dys unction, and the main effect of aprotinin during cardiopulmonary bypass is the maintenance of clot strength to the pre-CPB level by the preservation of platelet function.

  • PDF