• Title/Summary/Keyword: Hemostatic device

Search Result 4, Processing Time 0.02 seconds

Usefulness of Balloon-type Hemostatic Device After Transarterial Chemoembolization (간동맥 화학색전술 후 풍선형 지혈기구의 유용성)

  • Kim, Seung-Gi
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.181-186
    • /
    • 2019
  • Transarterial chemoembolization is one of the most representative procedures for puncture of the femoral artery. In addition, the same procedure is often repeatedly performed many times, and Hepatocellular carcinoma patients due to cancer is significantly lowered blood tests, regardless of platelet counts are not good enough to stop bleeding. More importantly, hepatocellular carcinoma has a high degree of complication and disease severity, which makes it less likely that the condition of the body will be relatively inferior to other patients. In order to prevent delayed hemorrhage of the femoral artery puncture site after the procedure, it is advised to absolutely stabilize the limb so that it does not bend the limb for 3 hours after climbing in the ward. Therefore, I have been complaining about inconvenience. In addition, in order to prevent delayed hemorrhage after hemostasis, balloon type hemostatic device was used instead of sand bag which was placed on hemostatic site. The results of this study were compared with the results of actual application. The use of a balloon-type hemostatic device to increase the effectiveness of continuous hemostasis and to minimize the inconvenience during the time of patient's absolute bed rest, rather than raising the sandbag to prevent primary delayed hemorrhage by various methods in transarterial chemoembolization. It can be used as a substitute for existing sand bags because it can alleviate pain, increase satisfaction, and can be used as a disposable one.

THE EFFECT OF HEMOSTATIC SOLUTIONS ON DENTIN PERMEABILITY (치과용 지혈제가 상아질 투과도에 미치는 영향)

  • Kim, Chong-Hyun;Shim, June-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.472-483
    • /
    • 2000
  • Before impression making in the fixed restorations or other prosthesis, hemostatic solutions are used for hemostasis and moisture control. Hemostatic solutions effectively control bleeding but their major ingredients, acid removes smear layers which are formed in the tooth preparation, exposes the dentinal tubular orifices which are occluded by smear layers, makes dentinal tubular fluid displace more easily to the various external stimulus, and according to the hydrodynamic theory, consequently causes dentin hypersensitivity. To know the effect of hemostatic solutions on dentin permeability, coronal dentin discs, 1mm in thickness, were prepared from extracted third molars free from decay and wear, and a split chamber device was used. Hydraulic conductance values and SEMs, which were measured before and after treatment with $Astringedentr^{(R)},\;Altract^(R)\;and\;Epri-dent^{(R)}$, were compared and ana-lysed. The following conclusions were drawn: 1. Hydraulic conductance values which were measured after the treatment of hemostatic solutions were increased in all groups(p<0.05). 2. %change values of hydraulic conductance were compared but no significant difference was found among the three hemostatic solutions(p<0.05). 3. On SEM observations of all groups, after treatment smear layers were removed and dentinal tubular orifices were partially exposed. On the basis of these conclusions, the reckless use of hemostatic solutions should be restricted, and when in use, various methods should be considered to protect dentin.

  • PDF

Effects of Bed Angles and Bed Rest Time Combined with Hemostatic Methods on Discomfort and the Occurrence of Hemorrhagic Complications in Patients after Transfemoral Cerebral Angiography (뇌혈관조영술 후 침상각도와 지혈방법에 따른 침상안정 시간이 불편감과 출혈합병증에 미치는 효과)

  • Kang, Young Ok;Park, In Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.3
    • /
    • pp.293-301
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of bed angles and bed rest time combined with hemostatic methods on discomfort and hemorrhagic complications in patients after transfemoral cerebral angiography. Methods: Data were collected from 93 inpatients following transfemoral cerebral angiography, from April 20 to September 23, 2016. Patients were grouped according to bed angle ($0^{\circ}$ vs. $30^{\circ}$) and bed rest time combined with hemostatic methods (4-hour bed rest after manual compression vs. 2-hour bed rest after applying vascular closure device). Results: There was a significant group differences on discomfort (F=46.44, p<.001). The post-hoc analysis showed the lowest score of discomfort in those with bed angle $30^{\circ}$ and 2-hour bed rest. There was no difference in hemorrhagic complications among 4 groups. Conclusion: The postangiograpy discomfort can be effectively reduced with the least hemorrhagic complications by bed angle $30^{\circ}$ elevation and 2-hour bed rest after applying vascular closure device for those underwent transfemoral cerebral angiography.

Preparation and characterization of medical silk sponge (인체적용을 위한 실크 스펀지의 제조 및 특성)

  • Jo, You-Young;Kweon, HaeYong;Lee, Kwang-Gill;Yeo, Joo-Hong;Lee, Heui-Sam
    • Journal of Sericultural and Entomological Science
    • /
    • v.51 no.1
    • /
    • pp.68-72
    • /
    • 2013
  • Fibroin and sericin are natural proteins obtained from cocoon and one of the spotlight materials for medical device. Medical device made of these proteins also has the advantage that this material is biodegradable in to amino acid. In this study, we prepared silk sponges using fibroin, sericin and additives. The characterizations of the silk sponges such as morphology, stability, and blood absorbency were observed. The structural stability of the silk sponge decreased significantly by increasing sericin contents. The effect on the concentrations of ethanol to induce crystallization was observed to be superior to 70% ethanol. Structural stability of silk sponges containing additives was very lower than those not containing additives. The blood absorbency of the silk sponges was found to be excellent, regardless of the composition of sericin and fibroin. The resilient power of these sponges was also very good, in spite of the repeated soaking and drying. Therefore, we expect that the silk sponges can be used medical supplies such as plastic implants and hemostatic cotton.