• Title/Summary/Keyword: Hemodynamic study

Search Result 421, Processing Time 0.031 seconds

Significance of Hemodynamic Effects on the Generation of Atherosclerosis

  • Suh Sang-Ho;Roh Hyung-Woon;Kim Dong-Joo;Kwon Hyuck-Moon;Lee Byoung-Kwon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.836-845
    • /
    • 2005
  • Atherosclerosis, which is a degenerative vascular disease, is believed to occur in the blood vessels due to deposition of cholesterol or low density lipoprotein (LDL). Atherosclerotic lumen narrowing causes reduction of blood flow due to hemodynamic features. Several hypothetical theories related to the hemodynamic effects have been reported : high shear stress theory, low shear stress theory, high shear stress gradient theory, flow separation and turbulence theory, and high pressure theory. However, no one theory clearly explains, the causes of atherosclerosis. The objective of the present study was to investigate the mechanism of the generation of atherosclerosis. In the study, the database of Korean carotid and coronary arteries for geometrical and hemodynamic clinical data was established. The atherosclerotic sites were predicted by the computer simulations. The results of the computer simulation were compared with the in vivo experimental results, and then the pathogenesis of atherosclerosis by using the clinical data and several hypothetical theories were investigated. From the investigation, it was concluded carefully that the mechanism of the generation of atherosclerosis was related to the hemodynamic effects such as flow separation and oscillatory wall shear stress on the vessel walls.

Hemodynamic Interpretation of Various Extraanatomical Bypasses: Clinical & Engineering Views

  • Lee, Byung-Boong;Kim, Young-Wook;Suh, Sang-Ho;Roh, Hyung-Woon;Kim, Dong-Ik;Yoo, Sang-Sin;Cho, Min-Tae;Huh, Sung
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.32-40
    • /
    • 2003
  • Axillo-bifemoral (Ax-Fem) bypass are now well accepted for bilateral iliac artery occlusion as the second best option. This extra-anatomical (unnatural) bypasses, however, have various hemodynamic liabilities affecting the patency. Hemodynamic conditions of each different type of Ax-Fem bypass were assessed with computer simulation model to determine the hemodynamically more sound type. Simulation models of five different types of Ax-Fem bypass were constructed. Our investigation based on the computer simulation models have shown distinct differences between two most popular Lazy-S type and Inverted-C type on the distribution of flow volume, shear stress and recirculation zone, etc., though both types have shown similar clinical results. Lazy-S type has shown better hemodyanmic status than inverted-C type. The theoretical advantage of "Lazy-S" type has never been adequately proved for its superiority clinically over the inverted-C type. Inverted-C type is now in more favor with clinically better results in spite of many hemodynamic liabilities including retrograde flow to the branching graft. The improvement of over-all long-term patency rate of various extra-anatomical bypasses is still warranted through proper correction of the hemodynamic liability. Even though clinical outcome of the extra-anatomical bypass has been equal regardless of the type of crossover femoral graft configuration, there are distinct differences on the hemodynamic characteristics among various types of configuration. Further hemodynamic study in the pulsatile flow status is warranted to correct hemodynamic defects with proper modification of various hemodynamic factors of each model.

  • PDF

Hemodynamic Responses of Rat Brain Measured by Near-infrared Spectroscopy During Various Whisker Stimulations

  • Lee, Seung-Duk;Koh, Dalk-Won;Kwon, Ki-Woon;Lee, Hyun-Joo;Lang, Yiran;Shin, Hyung-Cheul;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.166-170
    • /
    • 2009
  • NIRS (Near-infrared spectroscopy) is a relatively, new, non-invasive, and non-ionizing method of measuring hemodynamic responses in thick biological tissues such as the cerebral cortex. In this study, we measured the hemodynamic responses of the rat barrel cortex to whisker stimulation by using a frequency-domain NIRS system. We designed multiple optical probes comprising multi-mode optical fibers and manipulating arms, both of which can be easily applied to small animals. Various electrical stimulations were applied to rat whiskers at different voltage levels and stimulation frequencies. Our results show that the hemodynamic responses are highly dependent on the stimulation voltage level, and not so much on stimulation frequency. This paper suggests that NIRS technology is highly suitable for the study of small animal brains.

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF

Three-Dimensional Model Construction and Blood Flow Analysis of Coronary Artery using In-vivo Angiography (생체내 혈관조형술을 이용한 관상동맥의 3차원 형상화 및 혈류특성 해석)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Kwon, Hyuck-Moon;Lee, Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.753-758
    • /
    • 2003
  • The purpose of the present study was to establish the mechanism of the generation of atherosclerosis by analyzing the hemodynamic variables in the coronary artery where atherosclerosis occurs frequently. From the previous results, the stenosis phenomena due to atherosclerosis were related to not only biochemical reaction between blood and blood vessel but also the hemodynamic factors like flow separation and oscillatory wall shear stress. The present study aimed to investigate the causes of the generation and progression of atherosclerosis in the coronary artery. This study also aimed to develop the softwares which generate automatically three dimensional vascular models obtained by the angiogram images and the computer vision techniques. In the present study, the flow patterns for full three-dimensional hemodynamic characteristics were analyzed. To understand the three-dimensional hemodynamic characteristics, the wall shear stress distributions and secondary flows were investigated quantitatively.

  • PDF

Continuous Hemodynamic Profiles of Healthy Adults during Valsalva Maneuver (Valsalva Maneuver에 따른 정상 성인의 지속적 혈류역동 변화)

  • Kwak, Hye-Weon;Kim, Na-Hyun
    • Journal of Korean Biological Nursing Science
    • /
    • v.11 no.1
    • /
    • pp.68-76
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the hemodynamic changes in degree and duration that occur during Valsalva maneuver (VM). Furthermore, we wanted to investigate the patterns and mechanisms of physiological hemodynamic control. Method: Thirty six healthy college students were recruited from Y university. Each participant was provided with written informed consent. Blood pressure (BP), heart rate (HR), cardiac output (CO) were continuously recorded using the Finometer. Result: During the phase I of VM, means of systolic and diastolic pressures were increased by 32.15% and 38.28%, respectively, compared with basal values. HR and CO were decreased by 9.91% and 13.01%, respectively. Immediately after the maneuver (phase III), systolic and diastolic pressures were decreased by 5.05% and 6.24%, respectively, compared with those obtained in the phase II. HR and CO were elevated by 13.33% and 11.93%, respectively, compared to the levels of earlier phases. BPs were represented with overshoot in the phase IV, and recovered by baseline values about 20 sec after VM. Conclusion: These results demonstrated that hemodynamic changes are variable in the event of VM even in healthy humans. It will be valuable to accumulate more quantitative hemodynamic information in special populations such as the elderly and the patients with cardiovascular problems.

  • PDF

A Review on Impedance Cardiography and Its Oriental Medical Application (한의학적 활용을 위한 임피던스 심장기록법의 연구동향)

  • Ko, Young-Il;Lee, Hyon-Soo;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF

Changes of Hemodynamic Characteristics during Angulated Stenting in the Stenosed Coronary (관상동맥 협착부에 각이진 스텐트 시술시 혈류역학적 특성변화)

  • Suh Sang-Ho;Cho Min-Tae;Kwon Hyuck-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.717-720
    • /
    • 2002
  • The present study is to evaluate the performances of flow velocity and wall shear stress in the stenosed coronary artery using human in vivo hemodynamic Parameters and computer simulation. Initial and follow-up coronary angiographics in the patients with angulated coronary stenosis are performed. Follow-up coronary angiogram demonstrated significant difference in the percent of diameter in the stenosed coronary between two groups ($Group\;1:\;40.3{\%},\;Group\;2:\;25.5{\%}$). Flow-velocity wave obtained from in vivo intracoronary Doppler ultrasound data is used for the boundary condition for the computer simulation. Spatial and temporal variations of flow velocity vector and recirculation area are drawn throughout the selected segment of coronary models. The WSS of pre- and post-intracoronary stenting are calculated from three-dimensional computer simulation. Then negative shear stresses area on 3D simulation we noted on the inner wall of the post-stenotic area before stenting. The negative WSS is disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2. The present study suggest that hemodynamic forces exerted by pulsatile coronary circulation termed WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. The local recirculation area which has low or negative WSS, might lead to progression of atherosclerosis.

  • PDF

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.