• Title/Summary/Keyword: Helicopter Vibration

Search Result 134, Processing Time 0.027 seconds

Vibration Prediction of Helicopter Airframe (헬리콥터 동체의 진동 예측)

  • Yun, Chul Yong;Kim, Do-Hyung;Kang, Hee Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.340-346
    • /
    • 2013
  • This paper describes a helicopter vibration induced by main rotor in forward flight. The hub loads in the fixed frame, which are dominant source of helicopter vibration, are obtained by multi-blade summation of rotating blades loadings. The components of 3/rev, 4/rev, and 5/rev blades loadings are transmitted by blades to 4/rev hub loads in the fixed frame. The vertical vibrations of helicopter at pilot seat and copilot seat are calculated through rigid body transfer functions considering airframe to be rigid body. The blades are assumed to be elastic and undergo the flap, lag, and torsion motion and free wake aerodynamic model is used to calculate the precise blade loadings in the analysis. The 4/rev vertical vibration responses are analyzed from rotating blade loadings and fixed hub loadings.

  • PDF

Vibration Analyses and Design of Resonance Avoidance of the Unmanned Helicopter Master (무인 헬리콥터 마스터의 진동해석 및 공진회피 설계)

  • Lee, Seong-Chul;Son, In-Soo;Hur, Kwan-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.951-958
    • /
    • 2011
  • In this paper, the purpose is to investigate the vibration characteristics and the design of resonance avoidance of the unmanned helicopter master. Based on the Euler-Bernoulli beam theory for helicopter master, the equation of motion is derived by using extended Hamilton's principle. It was studied about the natural frequency of helicopter master as the design variances(tip mass, length and diameter of master). Also, it was compared the theoretical results for natural frequency with the results of FE analysis. The results of this study showed the vibration characteristics of helicopter master for the design of resonance avoidance.

Mount Design of Helicopter FLIR Sensor Using Experimental Dynamic Model (실험적 동적 모델을 이용한 헬기용 FLIR 센서의 마운트 설계)

  • 조기대
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1129-1136
    • /
    • 2004
  • The structural modification to install a heavy sensor was made at the front extremities of the foreign-produced helicopter operated in the Korea Navy Mounting the sensor directly to the nose structure is unlikely to be practical because it lowers a dynamic mode of the airframe close to rotor blade passing frequencies, leading to increased helicopter vibration. Unfortunately we have no information on dynamic characteristics of the imported helicopter. So the experimental modal model derived from shake testing on the overall airframe of a working helicopter was used to solve the sensor Installation problems. The sensitivity analysis was done to evaluate what the best of modification woo)d be. Simple ID model and experimental modal data for mount system with sensor were Incorporated into overall dynamic model to assess the effects of the sensor installation on helicopter. Modal testing for the modified helicopter shows that the airframe modes are sufficiently displaced from rotor passing frequencies. The mount system has been proven fight to be sufficiently stable to meet vibration-level requirement for all required operational profiles.

Technology Trend of Vibration/Noise Active Control in Helicopter (헬리콥터 능동 진동/소음 제어 기법 해외 동향 및 사례)

  • Kim, Deog-Kwan;Yun, Chul-Yong;Chung, Ki-Hoon;Kim, Seung-Ho
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.9 no.1
    • /
    • pp.77-89
    • /
    • 2011
  • The vibration and noise reduction issue is very important in helicopter since the thrust and flight control force of helicopter are generated by rotating drive system. In past, there was a passive method to reduce vibration and noise to focus on specified frequency. Now, there are various active method to reduce vibration and noise due to technology development. This paper describes the worldwide technology trend of vibration and noise active control in helicopter. At introduction, generalmethod of vibration and noise reduction.

  • PDF

Dynamic Analysis of a Helicopter Landing Gear with Considering Flexible Structural Modes (동체의 유연성을 고려한 헬기 착륙장치의 동특성 해석 연구)

  • Hyun, Young-O;Bae, Jae-Seoung;Kim, Young-Seok;Hwang, Jae-Up;Lim, Kyoung-Ho;Kim, Doo-Man;Kim, Tae-Wook;Hwang, Jai-Hyuk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.33-37
    • /
    • 2007
  • In this paper, a dynamic analysis of a helicopter landing gear with considering flexible structural modes has been investigated. The main body of the helicopter has been modeled as a flexible body using FEM code, then a few selected vibration modes of the helicopter main body have been used as basis for the dynamic analysis of the helicopter landing gear. The simulation of dynamic analysis was carried out on the base of ADAMS aircraft module. It has been found by a series of simulation that the flexible structural modes has a significant effect on the dynamic characteristics of helicopter landing gear as the flexibility of the main body is increased.

  • PDF

Rotating Frequency Analysis of a Helicopter Rotor Blade with Swpt Tips (후퇴각 날개끝이 있는 헬리콥터 로터깃의 회전주파수 해석)

  • ;Yang, Wei Dong
    • Journal of KSNVE
    • /
    • v.10 no.2
    • /
    • pp.229-239
    • /
    • 2000
  • To reduce the drag rise on the advancing helicopter rotor blade tips, the tip of the blade is modified to have sweep, anhedral and pretwist. The equations of motion of rotor blade with these tip angles were derived using Hamilton principle, programmed using FORTRAN and named as ARMDAS(Advanced Rotorcraft Multidisplinary Design and Analysis System). Rotating frequency analysis of rotor blades with swept tipe was performed that is necessary in conceptual and preliminary design phases of the helicopter design. Vibration analysis of non-rotating blades was also accomplished and compared with MSC/NASTRAN resutls for the basis of comparison with the vibration test data. The rotating frequency analysis of blades with an actual rotor blade data was also performed to verify coded program and to check the possibility of a resonance of an actual rotor blade at the specific rotating speed.

  • PDF

Vibration Health Monitoring of Helicopter Transmission Systems at Westland Helicopter Ltd.

  • Kang, Chung-Shin;Choi, Sun-Woo;Ahn, Seok-Min;Horsey, M.W;Stuckey, M.J
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.48-61
    • /
    • 2000
  • Korea Aerospace Research Institute (KARI) have gained experience with Helicopter Vibration Health Monitoring (VHM) System technology with the help of UK GKN-WHL. GKN-WHL have had many years of experience with the research and development of vibration analysis techniques to improve the health monitoring of helicopter transmissions. This activity was targeted at transmission rig testing at first, but the techniques have been progressively developed where they are now used as a part of integrated Health and Usage Monitoring (HUM) systems on many types of in-service and new helicopters. The technique development process has been considerably aided by an ever expanding database of transmission monitoring experience from both the rig testing and aircraft operations. This experience covers a wide range of failure types from naturally occurring faults to crack propagation studies and covering a wide range of transmission configurations. Primarily based on accelerometer signals GKN-WHL's vibration analysis methods have also been applied to a variety of other sensor types. The transition from an experimental environment to operational VHM systems has been a lengthy process, there being a need to demonstrate technique reliability as well as effectiveness to both regulatory (Airworthiness Authority) and commercial organizations. Another important feature of this process has been the development of close relationships with a number of VHM system hardware and software suppliers. Such an experienced GKN-WHL provides various raw vibration data which was acquired from transmission ground test rig and allow KARI to develop it's own analysis program. KARI made a program and then analyzed the data to coma pre with the results of GKN-WHL. The KARI's results both time domain signals and statistical values show comparable to GKN's.

  • PDF

Improvement and Operation of a Helicopter Tail-Fan Performance Test System (헬리콥터 테일팬 시험장치 개조 및 운용)

  • Lee, Je-Dong;Song, Keun-Woong;Kang, Hee-Jung;Sim, Jung-Wook;Kim, Seung-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.41-44
    • /
    • 2005
  • This paper described improvement and operation of a 'Tail-Fan' anti-torque performance test system KARI (Korea Aerospace Research Institute) developed a 'Tail-Fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the Tail-Fan. The test-rig was improved for full rotating test in 4300rpm(100%). Machinery and hydraulic parts ware changed to reduce vibration and to increase safety. To find the operation rotating speed for the performance test, vibration test were carried out rising accelerometers on tail gear box. The performance test conditions of the Tail-Fan to avoid a resonance were found from vibration test results. The Tail-Fan operation tests were performed safely frier to carry out performance test.

  • PDF

A Numerical Analysis on the Vibration Characteristics of Rotating Composite Blades (회전하는 복합재료 블레이드의 진동특성에 대한 수치해석)

  • Kee, Young-Jung;Song, Keun-Woong;Kim, Deog-Kwan;Shim, Jeong-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.300-303
    • /
    • 2006
  • The rotor blade of a helicopter is the key structural units and provides three components such as vertical lifting force, horizontal propulsive force and control force. With advancements in aerospace technology, composite materials have been widely used in lightweight structures. In addition, composites show great potential on the design of rotor blades due to the advantages of strength, durability and weight of the materials. In the operational condition of a helicopter, it is required the vibration characteristics of the rotating blades for avoiding resonance and analysis of efficient performance prediction et al. In this study, the CAMRAD-II is used for analyzing the vibration characteristics of rotating composite blades. The effects of rotating speed and collective angles are investigated. Also, the numerical results are compared with experimental data.

  • PDF

Helicopter Active Airframe Vibration Control Simulations Using an Exhaustive Test Method (Exhaustive 시험 기법을 이용한 헬리콥터 능동 기체 진동 제어 시뮬레이션)

  • Park, Byeong-Hyeon;Lee, Ye-Lin;Park, Jae-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.791-800
    • /
    • 2022
  • The number and locations of force generators and their force directions of Active Vibration Control System(AVCS) are important to maximize the airframe vibration reduction performance of helicopters. The present AVCS simulation using an exhaustive test method attempts to determine the best number and locations of force generators and their force directions for maximization of the airframe vibration reduction performance of UH-60A helicopter at 158 knots. The 4P hub vibratory loads of the UH-60A helicopter are calculated using DYMORE II, a nonlinear multibody dynamics analysis code, and MSC.NASTRAN is used to predict the vibration responses of the UH-60A airframe. The AVCS framework with an exhaustive test method is constructed using MATLAB Simulink. As a result, when applying AVCS with the optimal combination of the force generators, the 4P airframe vibration responses of UH-60A helicopter are reduced by from 19.35% to 98.07% compared to the baseline results without AVCS.