• Title/Summary/Keyword: Helical

Search Result 1,160, Processing Time 0.026 seconds

THE EFFECTS OF TRANSFORMING GROWTH FACTOR-$\beta$ ON THE VIABILITY OF HUMAN PERIODONTAL LIGAMENT CELL AND ON THE EXPERIMENTAL TOOTH MOVEMENT IN RAT (Transforming growth factor-$\beta$가 인체 치주 인대세포 활성 및 백서의 실험적 치아 이동에 미치는 영향에 관한 연구)

  • Park, Yun-Kyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.311-327
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of Transforming Growth Factor-${\beta}$ (TGF-${\beta}$) on the viability of human periodontal ligament cells, in-vitro and on the experimental tooth movement in rat, in-vivo. Human periodontal ligaments were cultured from the first premolar tooth extracted for the purpose of the orthodontic treatment. 0.1, 1, 5 and 10ng/m1 of TGF-${\beta}$ was given to the cultured wells, respectively and the viability was evaluated by MTT assay. Twenty Sprague-Dawley rats were divided into 5 experimental groups(4 rats in each) where 100g of force was applied from helical spring across the maxillary incisors. TGF-${\beta}$ was injected via Hamilton syringe into the periodontal ligament at the mesial and the distal surface of a maxillary incisor of 2 rats in each experimental group. Phosphate buffer saline(PBS) was injected in 2 other rats as controls. Experimental groups were sacrificed at 1, 3, 7, 14 and 28 days after force application, respectively. The obtained tissues were evaluated histologically. The obtained results were as follows: 1. The viability of periodontal ligament cells in 0.1ng/ml of TGF-${\beta}$ was not significantly different from that of control at 1-, 2- and 3-day of cultivation. 2. The viability of periodontal ligament cells was significantly increased at 3-day in 1ng/ml or 5ng/ml of TGF-${\beta}$, and at 2-,3-day in 10ng/ml of of TGF-${\beta}$. 3. The zone of hyalinization in periodontal ligament in pressure side was smaller in TGF-${\beta}$ injection group than that in control group at 3-day after the application of experimental force in rat. But no difference was seen after 7-day. 4. Osteoclastic activity and capillary prolieferation in pressure side were greater in TGF-${\beta}$ injection group than that in control group at 3-day to 7-day. 5. Osteoblastic activity and new bone fomation in tension side were greater in TGF-${\beta}$ injection group than that in control group at 3-day to 14-day.

  • PDF

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

THE EXPRESSION OF NITRIC OXIDE SYNTHETASE IN THE EXPERIMENTAL TOOTH MOVEMENT IN RATS (백서의 실험적 치아이동시 Nitric Oxide Synthetase의 발현 양상)

  • Park, Dong-Kwon;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.107-120
    • /
    • 2001
  • Nitric oxide(NO) has been reported to be one of the mediators relating to bone remodelling. Nitric oxide is synthesized from L-arguinine by nitric oxide synthetase(NOS), which is largely divided Into two groups. One group which is composed of $NOS_1\;and\;NOS_3$, is dependent of calcium or calmodulin. The other consisted of $NOS_2$, which is independent of calcium or calmodulin. NOS is thought to be a possible intermediate affecting in the course of tooth movement. This study was designed to evaluate the expression of nitrous oxide synthetase(NOS) in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for $NOS_2\;and\;NOS_3$. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats), and 6 experimental groups(24 rats), to which 75g of force was applied, with helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. After that, the tissues of the control group and experimental groups were studied immunohistochemically. The results were as follows: 1. In control group, the expression of $NOS_3$ was rare in gingiva, dentin, periodontal ligament and alveolar bone, and was mild in the capillaries of pulp and intermaxillary suture. And the expression of $NOS_2$ showed similar pattern to that of $NOS_3$. 2. There were no differences in the expression of $NOS_2\;or\;NOS_3$ in dentin, gingiva, cementum, cementoblast and odontoblast, between control and experimental groups, regardless of the duration of the force application. 3. The expression of $NOS_3$ began to increase at 4 days and showed to the highest degree at 7 days after force application, in the apical region of pressure side of periodontal ligament in experimental groups. 4. The expression of $NOS_3$ in alveolar bone was rare until 7 days, after which it increased to mild degree at 14 days through 28 days in experimental group. But there was no difference between pressure and tension side of periodontal ligament. 5. The expression of $NOS_2$ in periodontal ligament was mild from 7 days after force application, regardless of the side of periodontium, which was generally more evident than that of $NOS_3$. 6. The expression of $NOS_2$ in alveolar bone increased to mild degree at 14 days after force application, and it was evident in osteoblasts, osteoclasts and osteocytes. And the expression of $NOS_2$ was little more stronger in the tension side than that of pressure side of alveolar bone.

  • PDF

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

Anatomical Studies on the Features of Rays in Compression Wood of Korean Red Pine(Pinus densiflora S. et Z.) (소나무(Pinus densiflora S. et Z.) 압축이상재(壓縮異常材)의 방사조직(放射組織) 특성(特性)에 관한 해부학적(解剖學的) 연구(硏究))

  • Chung, Youn Jib;Lee, Phil Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.2
    • /
    • pp.119-131
    • /
    • 1989
  • This experiment was executed to investigate and compare qualitative and quantitative anatomical features in compression wood, opposite wood, and side wood formed in a bent stem, a straight branch, and an exposed horizontal root of Korean red pine(Pinus densiflora S. et Z.). The respective four discs containing compression wood taken at 20cm interval both in stem and branch as well as a disc containing well developed compression wood from horizontal root were analyzed. Percentage of compression wood and eccentricity showed decreasing tendency with the increasing distance in height direction of stem and length direction of branch. The qualitative anatomical features of compression wood appeared to differ from those of side and opposite wood in very gradual tracheid transition from earlywood to latewood, roundish tracheid shape on cross surface, tracheid distortion at tip on radial surface, existence of intercellular space, and helical cavity in tracheid wall. And the differences in these qualitative features among the compression wood, opposite wood, and side wood became less intensive with the decreasing trends in percentage of compression wood and eccentricity. The quantitative anatomical features in compression wood also appeared to be wider in that respective widths of fusiform and uniseriate ray than those of opposite and side wood, but the heights of fusiform and uniseriate ray in compression wood were smaller than in opposite and side wood. The number of horizontal resin canal(fusiform ray) and uniseriate ray, however, showed no differences among the compression wood, opposite wood, and side wood. And the number of vertical resin canal in unit area, $4{\pi}mm^2$ of compression wood was fewer than that in opposite wood, whereas numerous vertical resin canals contained in a growth ring. These rays of compression wood seemed to be characterized by smaller height and wider width than those of opposite and side wood.

  • PDF

A Study on the Expression of Connexin 43 in the Experimental Tooth Movement of Rat (백서의 실험적 치아이동시 connexin 43의 발현에 관한 연구)

  • Lim, Jeong-Hyeon;Kang, Kyung-Hwa;Lee, Jong-Jin;Kim, Eun-Cheol;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.525-534
    • /
    • 2001
  • Bone remodeling in response to force requires coordinated actions of osteoblasts, osteoclasts, osteocytes, and periodontal ligament cells. Coordination among these cells may be mediated, in part, by cell-to-cell communication via gap junctions. This study was designed to evaluate the expression of gap junction, connection 43 In periodontal tissue during the experimental movement of rat's incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for connexin 43. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats), and 6 experimental groups(24 rats) where 75g of force was applied from helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. And the tissues of a control group and experimental groups were studied immunohistochemically. The results were as follows : 1. In control group, the expression of connexin 43 was rare in gingiva, dentin, cementum, periodontal ligament, and bone cells. 2. In experimental group, the expression of connexin 43 was increased in pulp, periodontal ligament, osteoblasts, and osteoclasts, comparing to that in control. And it was rare in gingiva, dentin, and odontoblasts regardless of the duration of force application, which was not different from that of control group. 3. The expression of connexin 43 in pulp of experimental group began to increase in 4-day after force application and got to the highest degree at 7-day. And it decreased after 14-day to be similar to that of control group at 28-day. 4. The expression of connexin 43 in periodontal ligament was noted in small capillaries adjacent to alveolar bone, showing higher intensity of immunolabelling after 4-day And it was stronger in the pressure side than in tension side of periodontal ligament. After 7-day, decrease in connexin 43 expression was observed. 5. The expression of connexin 43 in alveolar bone began to increase 1-day, reached to the highest degree at 4-day, and decreased at 7-day. And the expression in osteoclasts was more than that in osteoblasts or osteocyte at 7-day.

  • PDF

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF