• Title/Summary/Keyword: Height variation

Search Result 1,130, Processing Time 0.028 seconds

Analysis of the Effects by Multi-Stacking of Superstrates on Circular-Polarized Patch Antenna (원형편파 패치안테나에서 상부덮개의 다중 적층에 의한 효과 분석)

  • Lee, Sangrok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.202-209
    • /
    • 2014
  • In this paper, we analyzed the effects by multi-stacking superstrates over the circular-polarized patch antenna. The previous works considered a single-layered superstrate or a superstrate with multiple layers, and did not almost consider the axial ratio at the performance analysis. First, the effect of center frequency shift is analyzed by the variation of air-gap height between patch antenna and superstrate. The center frequency is down-shifted at the smaller air-gap height and has almost the same frequency as patch antenna at the air-gap height of $005{\lambda}_0$. Second, the antenna performance is analyzed by multi-stacking superstrates with the air-gap height of $005{\lambda}_0$. As the number of multi-stacked superstrates increase, antenna gain has a linear increase and axial ratio is exponentially deteriorated. In addition, it has also been observed that the antenna performance has the same trend with the number of multi-stacked superstrates as the thickness of superstrate increases. Finally, we confirmed that it is possible to design the CP patch antenna with the scalable gain and less than 3dB axial ratio by stacking the superstrate.

The Seismic Behavior of Corrugated Steel Plate Lining in Cut-and-Cover Tunnel (개착식 터널에서 파형강판 라이닝의 동적 거동 특성)

  • Kim Jung-Ho;Kim Nag-Young;Lee Yong-Jun;Lee Seung-Ho;Chung Hyung-Sik
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.233-247
    • /
    • 2005
  • Most tunnel lining material which has been used in the domestic is a concrete. But many problems as the construction period, the cost, and the crack occurrence for the design, construction, and management were happened in the concrete lining. For this reason, many research institutes like the Korea Highway Corporation recognize the necessity of an alternate material development and grow on the interest for that. So in this study, the seismic behaviour characteristics for the application of the Corrugated Steel Plate Lining in cut-and-cover tunnel are evaluated as several conditions for the backfill height, the cutting slope, and the relative density of backfill soil are changed. The compressive stress which is calculated in the Corrugated Steel Plate Lining by the seismic load is decreased as the backfill height increases and the cut slope grows gentle. Also, the moment shows the tendency of decrease according to the increase of the backfill height. But in the case of the relative density of the backfill soil is small, the moment increases according to the increase of the backfill height and affects the dynamic behaviour characteristic. So it is considered that the relative density of the backfill soil is also the important point. As the result in analyzing the seismic response characteristics of the reinforcement spacing of the Corrugated Steel Plate, the variation in the compressive force is hardly happened, but the moment and the shear force increase on the reinforcement spacing being narrow.

  • PDF

Heterosis Effects of Body Weight and Jumping Height in Rotational Crossing of Two-Subspecies of Mice

  • Kurnianto, E.;Shinjo, A.;Suga, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.7
    • /
    • pp.888-893
    • /
    • 2000
  • The present study was conducted to evaluate heterosis effects of body weight and jumping height for successive generations of rotational crossing using two subspecies of mice which are very different in body weight and in genetic relationship from each other. Domesticated laboratory mouse $CF_{{\sharp}1}$ (C) and Yonakuni wild mouse (Y) were used as materials. Two groups of rotational crossing was made according to the parent used at the beginning of crosses, C male$\times$Y female and Y male$\times$C female. These crosses were done to produce the first ($G_1$ and $G_1{^{\prime}}$), second ($G_2$ and $G_2{^{\prime}}$) and third generations ($G_3$ and $G_3{^{\prime}}$) with sire used was alternated. Individual body weights were weighed at 1 (wk1), 3 (wk3), 6 (wk6) and 10 weeks of age (wk10) and jumping heights were measured at six weeks of age (wk6). Only the first litter used. For body weight, results of this study showed that genetic group effects were significant (p<0.01) source of variation at all ages studied. Sex effects were significant (p<0.01) at wk3, wk6 and wk10, but not at wk1. Significant interaction effects (p<0.01) between genetic group and sex were found at wk6 and wk10. The C mice with large maternal effects produced heavier offspring body weight and crosses using sire of this subspecies maintained heavy weight compared to wild Y mouse sire that has small body size. Heterosis tended to exist at the rotational crossing started from Y male C female. For jumping height, effects of genetic group and sex were significant, sire and dam effects (heterosis) exhibited from the first to third generations, and no maternal effects were observed.

Analysis of Spray Characteristics of Tractor-mounted Boom Sprayer for Precise Spraying

  • Kim, Ki-Duck;Lee, Hyeon-Seung;Hwang, Seok-Joon;Lee, Young-Joo;Nam, Ju-Seok;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.258-264
    • /
    • 2017
  • Purpose: This study determines the spray characteristics and effective spray width of a tractor-mounted commercial boom sprayer through experiments. Methods: Performance tests were conducted to investigate the spray characteristics of the nozzles on a commercial boom sprayer. The flow rate and spray width of a single nozzle were measured at three levels of spray pressure (0.5, 0.7, and 1.0 MPa) and spray height (15, 30, and 45 cm), respectively. The average value of three repetition tests was used as the representative value. A coefficient of variation (CV) was used as an index of spray uniformity, and the width that guarantees CV values of approximately 15% was determined as the effective spray width. The spray characteristics of the overall boom sprayer were derived analytically by superimposing the spray characteristics of a single nozzle. Results: The test results for a single nozzle showed that the spray width tended to increase as the spray height and spray pressure increased. The effective spray width for a single nozzle was the largest at a spray pressure of 1.0 MPa and spray height of 45 cm, which resulted in a coverage of 84 cm of width. The effective spray width for the entire boom sprayer was also the largest at the spray pressure of 1.0 MPa and spray height of 45 cm, with a magnitude of 424.5 cm. The chemical spraying work in an actual field was simulated by applying a spray width of 400 cm. As a result of the operation for three swaths, the CV value was less than 10% for 1,200 cm of the overall spray width, which meant that uniform application was achieved. Conclusions: It was reasonable to set the effective spray width of the boom sprayer used in this study to 400 cm.

Seasonal Variation of Meteor Decay Times Observed at King Sejong Station ($62.22^{\circ}S$, $58.78^{\circ}W$), Antarctica

  • Kim, Jeong-Han;Kim, Yong-Ha;Lee, Chang-Sup;Jee, Geon-Hwa
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.29.4-30
    • /
    • 2010
  • A VHF meteor radar at King Sejong Station ($162.22^{\circ}S$, $58.78^{\circ}W$), Antarctica has been observing meteors during a period of March 2007-July 2009. We analyzed the height profiles of the observed meteor decay times between 70 and 95 km by classifying strong and weak meteors according to their estimated electron line densities. The height profiles of monthly averaged decay times show a peak whose altitude varies with season in the range of 80~85 km: higher peak in southern spring and summer than in fall and winter. The higher peak during summer is consistent with colder temperatures that cause faster chemical reactions of electron removal, as effective recombination rates measured by rocket experiments. The height profiles of 15-min averaged decay times show a clear increasing trend with decreasing altitude from 95 km to the peak altitude, especially for weak meteors. This feature for weak meteors is well explained by ambipolar diffusion of meteor trails, allowing one to estimate atmospheric temperatures and pressures, as in previous studies. However, the strong meteors show not only significant scatters but also different slope of the increasing trend from 95 km to the peak altitude. Therefore, atmospheric temperature estimation from meteor decay times should be applied for weak meteors only. In this study, we present the simple model decay times to explain the height profiles of the observed decay times and discuss the additional removal processes of meteor trail electrons through the empirical recombination and by icy particles.

  • PDF

Long Term Flux Variation Analysis on the Boseong Paddy Field (보성 농업지역에서의 장기간 플럭스 특성 분석)

  • Young-Tae Lee;Sung-Eun Hwang;Byeong-Taek Kim;Ki-Hun Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

Numerical investigation of wind interference effect on twin C-shaped tall buildings

  • Himanshoo Verma;R. S. Sonparote
    • Wind and Structures
    • /
    • v.37 no.6
    • /
    • pp.425-444
    • /
    • 2023
  • This study is to investigate the effect of interference between two C-shaped high-rise buildings by computational fluid dynamics (CFD), focusing on the variation of the local pressure coefficient (CP) and the mean pressure coefficient (CPMEAN). Sixteen building position cases are considered for the present study. These cases were based on the position and height of the interference building (IB). The pressure coefficient (CP) is calculated on the principal building (PB) and is compared with an isolated building identical in shape and size. The interference effect on PB has also been presented in reference for the interference factor (IF). According to the findings, the maximum force coefficient on the PB is 0.971 and it is 10.97% more than the isolated PB when IB is located at position 2b (two times the width of the building), and the interfering height of 13H/15 mm. The moment coefficient on PB is 1.27, which is 27.36% less than the isolated case in which IB pushed 2b to 3b in the y direction with 750 mm height. In most of the cases, because of the shielding effect of the IB, the value of force coefficient (CF) on PB has been reduced. On the face of the PB, there are also considerable differences in the mean pressure coefficient CPMEAN. When IB was positioned at a location of 2b in Y direction and an interfering height of 13H/15 mm, the maximum CPMEAN (1.58) was observed on the leeward face of PB.

The Variation of Winter Buds among 10 Selected Populations of Kalopanax septemlobus Koidz. in Korea

  • Kim, Sea-Hyun;Ahn, Young-sang;Jung, Hyun-Kwon;Jang, Yong-Seok;Park, Hyung-Soon
    • Plant Resources
    • /
    • v.5 no.3
    • /
    • pp.214-223
    • /
    • 2002
  • The objective of this study was to understand the conservation of gene resources and provide information for mass selection' of winter bud characters among the selected populations of Kalopanax septemlobus Koidz using analysis of variance(ANOVA) tests. The obtained results are shown below; 1. Ten populations of K. septemlobus were selected for the study of the variation of winter bud characters in Korea. The results of the analysis of variance(ANOVA) tests shows that there were statistically significant differences in all of the winter bud characters among those populations. 2. Correlation analysis shows that width between Height and DBH(Diameter at breast height) characters have negative relationship with all of the characters, as ABL(Apical branch length), ABW(Apical branch width), AWBL(Apical branch winter bud length), AWBW(Apical branch winter bud width), ABT(Apical branch No. of thorns), ABLB(Apical branch No. of lateral bud) and LBL(Lateral branch length), LBW(Lateral branch width), LBT(Lateral branch No. of thorns), LBLB(Lateral branch No. of lateral bud). 3. The result of principal component analysis(PCA) for winter buds showed that the first principal components(PC' s) to the fourth principal component explains about 78% of the total variation. The first principal component(PC) was correlated with AWBW, LWBW, and LBL and the ratio of ABL/ABW and LBL/LBW out of 16 winter bud characters. The second principal component correlated with ABL, ABW, ABLB, LWBL(Lateral branch winter bud length), and LBW and the ratio of AWBL/AWBW. The third principal component correlated with ABL, ABW, LWBL, LBL, and the ratio of LBL/LBW. The fourth principal component correlated with LBL and the ratio of LWBL/LWBW(Lateral branch winter bud width), LBL/LBW. Therefore, these characters were important to analysis of the variation for winter bud characters among selected populations of K. septemlobus in Korea. 4. Cluster analysis using the average linkage method based on 10 selected populations for the 16 winter bud characters of K. septemlobus in Korea showed a clustering into two groups by level of distance 1.1(Fig. 3). As can be seen in Fig. 3, Group I consisted of three areas(Mt. Sori, Mt. Balwang and Mt. Worak) and Group Ⅱ contisted of seven areas(Suwon, Mt. Chuwang, Mt. Kyeryong, Mt. Kaji, Mt. Jiri, Muan, and Mt. Halla). The result of cluster analysis for winter bud characters corresponded well with principal component analysis, as is shown in Fig. 2.

  • PDF

Characteristics of Waves around the Sea near Busan New Port Based on Continuous Long-term Observations during Recent 10 years (최근 10년간 장기연속관측에 근거한 부산항 신항 인근 해역의 파랑특성)

  • Jeong, Weon-Mu;Oh, Sang-Ho;Baek, Won-Dae;Chae, Jang-Won
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.2
    • /
    • pp.109-119
    • /
    • 2012
  • Long-term wave observation was carried out near Busan New Port and the major wave characteristics were analyzed. At Busan New Port, waves from south direction were predominant throughout the year, while waves from the west, developed at the north sea of Geoje island, appeared almost the same frequency in winter season, showing apparent seasonal variation. During the observation period, the significant wave height was mostly less than 1 m, but it reached its maximum of 8.0 m when typhoon Maemi passed on September 2003. Also, the seasonal variation was hardly observed except July. In contrast, seasonal variation was apparent for the significant wave period, whose peak ranges 4~5 s in summer whereas about 3 s in winter. The largest significant wave period was 15.56 s, observed on June 2003. Meanwhile, the annual variation was negligible for mean wave direction as well as significant wave height and period. Further analysis of the wave data acquired for 5 years at 4.5 km south, in the south sea of Daejuk island, confirmed high correlation between the two observation points in summer and vice versa in winter.

The Variation of Population of Pinus koraiensis Sieb. et Zucc. in Mt. Jiri (지리산(智異山) 잣나무집단(集團)의 변이(變異)에 관(關)한 연구(硏究))

  • Lee, Kang Young
    • Journal of Korean Society of Forest Science
    • /
    • v.34 no.1
    • /
    • pp.1-14
    • /
    • 1977
  • These studies were carried out to know the variation of morphological tree forms, needles, cotyledons, seed characters and top height growth of seedlings of Pinus koraiensis S. et Z. by populations in Mt. Jiri. The results are summarized as follows: 1. It was observed that the characteristics of length, needles of serration density of needles, percentage of full seeds length, of seeds, thickness, of seeds length of cotyledons, width of cotyledon, numbers of the stomata line in cotyledons and the top height growth of seedlings were significantly different in individual trees and populations. 2. The characteristics of branch angle specific gravity of wood and resin canal numbers of cotyledons were significantly different in populations. 3. It was that the characteristics of numbers of stomata line, width, of seeds weight, of seeds serration density of cotyledons, numbers of cotyledons were significantly different in individuals. 4. The resin canals of needles showed three principle resin canals in individual trees and population, and the coefficients of variation were not shown in individual trees and populations. Stem forms showed to be a straight form with all populations. 5. The characteristics of cotyledons had generally higher tendency than the characteristics of needles in comparison with coefficience of variation.

  • PDF