• Title/Summary/Keyword: Height reproducibility

Search Result 36, Processing Time 0.022 seconds

Three-dimensional Simulation of Wave Reflection and Pressure Acting on Circular Perforated Caisson Breakwater by OLAFOAM (OLAFOAM에 기초한 원형유공케이슨 방파제의 반사율 및 작용파압에 관한 3차원시뮬레이션)

  • Lee, Kwang-Ho;Bae, Ju-Hyun;Kim, Sang-Gi;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.6
    • /
    • pp.286-304
    • /
    • 2017
  • In this study, we proposed a new-type of circular perforated caisson breakwater consisting of a bundle of latticed blocks that can be applied to a small port such as a fishing port, and numerically investigated the hydraulic characteristics of the breakwater. The numerical method used in this study is OLAFOAM which newly added wave generation module, porous media analysis module and reflected wave control module based on OpenFOAM that is open source CFD software published under the GPL license. To investigate the applicability of OLAFOAM, the variations of wave pressure acting on the three-dimensional slit caisson were compared to the previous experimental results under the regular wave conditions, and then the performance for irregular waves was examined from the reproducibility of the target irregular waves and frequency spectrum analysis. As a result, a series of numerical simulations for the new-type of circular perforated caisson breakwaters, which is similar to slit caisson breakwater, was carried out under the irregular wave actions. The hydraulic characteristics of the breakwater such as wave overtopping, reflection, and wave pressure distribution were carefully investigated respect to the significant wave height and period, the wave chamber width, and the interconnectivity between them. The numerical results revealed that the wave pressure acting on the new-type of circular perforated caisson breakwaters was considerably smaller than the result of the impermeable vertical wall computed by the Goda equation. Also, the reflection of the new-type caisson breakwater was similar to the variation range of the reflection coefficient of the existing slit caisson breakwater.

THE COMPARATIVE STUDY OF CORRELATION ON HAND-WRIST WITH CERVICAL VERTEBRAE FOR SKELETAL MATURATION IN MIXED DENTITION CHILDREN WITH NORMAL OCCLUSION (혼합치열기 정상교합아동의 수완부골과 경추골의 성숙도 비교 연구)

  • Kim, Myoung-Gook;Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi;Kim, Jee-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.237-243
    • /
    • 2011
  • The purpose of study is for the certified correlations of hand-wrist radiograph with cervical vertebrae for skeletal maturation in children. Normal evaluation devices of growth stage is sexual feature, biological age, tooth development stage, height and weight. Evaluation of growth potential is very important for childhood and puberty. The skeletal developmental stages were evaluated by using the hand-wrist radiograph and cephalometric radiograph that obtained from 6 to 18 years old children. 1. Chronologic age was not more suitable indicator of skeletal development compared to Skeletal Maturity Indicators(SMI) and Cervical Vertebrae Maturation(CVM) stages. 2. SMI and CVM stages for females occurred earlier than that for male. 3. SMI 1 and 2 stages were corresponded to CVM 1; SMI 3,4 = CVM 2; SMI 5,6 = CVM 3. 4. Reproducibility and reliability of observer for SMI and CVM were excellent. This results suggest CVM stage is comparable to SMI stage in terms of evaluating the skeletal development.

Improvement of a Planning Technique Based on Heuristic Target Shaping for Stereotactic Radiosurgery (방사선 수술시 경험적 표적 근사화에 근거한 최적화 방법 개선)

  • Oh Seungjong;Choi Kyoung-Sik;Song Ju-Young;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.176-182
    • /
    • 2005
  • Stereotactic radiosurgery (SRS) is a technique to deliver a high dose to a target region and a low dose to a critical organ through only one or a few irradiation. The SRS must be planned exactly. Currently the surgery plan is peformed by trial and error method. There are many questions about the reliability and reproducibility of the plan result. This study Improve each step of the Oh's method based on heuristic target shaping to obtain the better result. The target was reconstructed using cylinders with same height and the neighbored cylinders were combined according to the difference of each center and diameter. Then, spheres were packed within each cylinders by the packing rules. Two virtual targets were used to compare this method with Oh's method. As a result, the numbers of isocenter were successfully reduced - more than $35\%$ and $26\%$ - without serious differences of proscription isodose to tumour volume ratio (PITV) and maximum dose to proscription dose ratio (MDPD). This technique using cylinder piling and sphere packing will be a helpful tool to planner in stereotactic radiosurgery.

  • PDF

Surface Dose Evaluation According to the Environment Around the Patient after Nuclear Medicine Examination (핵의학 검사 후 환자의 주위 환경에 따른 표면 선량 평가)

  • Lee, Young-Hee;Park, Jae-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.943-948
    • /
    • 2021
  • The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18F by injecting 20 and 10 mCi respectively into the NEMA phantom, and then measuring the surface dose for 60 minutes by positioning the phantom at a height of 1 m above the surface, at a distance of 0, 5 and 10 cm from the wall, and at the same location as the phantom facing the wall. Each experiment was repeated five times for reproducibility of the experiment and one way analysis of variability (ANOVA) was performed for significance testing and Tukey was used as a post-test. The study found that surface doses of 220.268, 287.121, 243.957, and 226.272 mGy were measured at 99mTc, respectively, in the case of empty space and in the case of 0, 5 and 10 cm, while those of 18F were measured at 637.111, 724.469, 657.107, and 640.365 mGy, respectively. In order to reduce changes in surface dose depending on the patient's location while waiting, it is necessary to keep the distance from the ground or the wall where the patient is closely adhered to, or install an air mattress, etc., to prevent the scattered lines as much as possible, considering the scattered lines due to the wall etc. in future setup of the patient waiting room and safety room, and in addition to the examination, the external skin width may be reduced.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Cephalometric study on head posture according to the Classification of Malocclusion (부정교합 분류에 따른 두경부 위치의 두부방사선 계측학적 연구)

  • Hwang, Chung-Ju;Kim, Suk-Hyun;Kil, Jae-Kyung
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.221-230
    • /
    • 1997
  • It has been known that head posture may influence directly and/or indirectly the growth and development of craniofacial morphology and can also be influenced by the funtional demand of physiologic activity. It was reported that facial morphology has close relationships with hyoid bone position and head posture. In many previous studies, Natural Head Posture(NHP) was guided, and also it was shown that NHP has high degree of reproducibility. Otherwise, There was few study about the relationship of head posture, with routine cephalometric film which is used for clinical orthodontic purpose. In this study, according to the Wits and ANB of initial cephalometric film which was taken with vertical pendulum as representative of true vertical reference line. We classified the subjects which is comprised of 60 adult female patients into Class I, II, III (Cl I, II, III)and we tried to find out the correlation of head posture and hyoid bone position according to the classification of malocclusion. As a result of our research, we found the followigs. 1. In comparison of vertical position of hyoid bone relative to the cranial base. the position of hyoid bone of Cl III was lower than that of Cl II. 2. In comparison of anteriorpostes or position of hyoid bone, relative to the cervical column. The position of hyoid bone of Cl III was more anterior than that of a II 3. in comparison of vertical position of hyoid bone relative to mandible. There was no significant correlation aumoug the groups of malocclusion. 4. ANB and Wits showed no significant correlation with hyoid bone position. 5. The relative extension of head, which was noted in Cl II, showed negative with Sum, ANB. 6. In Cl II and Cl III, Post to Ant facial height showed positive correlation with NSL/VER.

  • PDF