• Title/Summary/Keyword: Height of Spray

Search Result 143, Processing Time 0.023 seconds

Empirical Correlations for Breakup Length of Liquid Jet in Uniform Cross Flow-A Review

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2013
  • The empirical correlations for the prediction of breakup length of liquid jet in uniform cross flow are reviewed and classified in this study. The breakup length of liquid jets in cross flow was normally discussed in terms of the distances from the nozzle exit to the column breakup location in the x and y directions, called as column fracture distance and column fracture height, respectively. The empirical correlations for the prediction of column fracture distance can be classified as constant form, momentum flux ratio form, Weber number form and other parameter form, respectively. In addition, the empirical correlations for the prediction of column fracture height can be grouped as momentum flux ratio form, Weber number form and other parameter form, respectively. It can be summarized that the breakup length of liquid jet in a cross flow is a basically function of the liquid to air momentum flux ratio. However, Weber number, liquid-to-air viscosity ratio and density ratio, Reynolds number or Ohnesorge number were incorporated in the empirical correlations depending on the investigators. It is clear that there exist the remarkable discrepancies of predicted values by the existing correlations even though many correlations have the same functional form. The possible reasons for discrepancies can be summarized as the different experimental conditions including jet operating condition and nozzle geometry, measurement and image processing techniques introduced in the experiment, difficulties in defining the breakup location etc. The evaluation of the existing empirical correlations for the prediction of breakup length of liquid jet in a uniform cross flow is required.

Effects of Pinching and Retardants on Growth and Flowering of Celosia argentea native to Korea (한국자생 개맨드라미의 적심 및 왜화제 처리가 생장 및 개화에 미치는 영향)

  • Lee, Jeong-Ho;Kim, Kyu-Sick;Song, Cheon-Young
    • Korean Journal of Plant Resources
    • /
    • v.19 no.5
    • /
    • pp.573-579
    • /
    • 2006
  • This experiment was conducted to investigate growth and flowering characteristics of Celosia argentea native to Korea treated by pinching and growth retardants, diniconazole, hexaconazole and daminozide. The more increased from one to three times of pinching, the more decreased in plant height and internode length but increased number of spadix and lateral branch. Spray application of diniconazole $50mg{\cdot}L^{-1}$ and daminozide $6,800mg{\cdot}L^{-1}$ decreased plant height, internode length and leaflength, but increased number of spadix, number of leaves and number of lateral branch.

Genetic Analysis on the Linkage Relationship Between Blast Resistance Gene and Plant Height Gene in Rice (Oryza sativa L.) (수도 도열병 저항성과 간장간의 연관에 관한 유전분석)

  • Ha, S.B.;Chae, Y.A.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.3
    • /
    • pp.203-208
    • /
    • 1984
  • This study was investigated to know the possible linkage relationship between blast resistance gene and plant height gene in rice. Two resistant varieties, Tadukan and Tetep were crossed with six susceptible semi-dwarf tester lines. Progenies derived from the crosses were inoculated with spray method at 3-4 leaf stage with blast races, C-8$^{+t}$ and T-2$^{+t}$. The results indicated that: (1) Resistance of Tadukan and Tetep to the C-8$^{+t}$ was controlled by a single dominant gene, respectively. (2) Resistance of Tadukan and Tetep to the T-2$^{+t}$ was expressed by complementary gene action between two dominant genes, respectively. (3) No linkage relationship was found between resistance gene and plant height gene of both Tadukan and Tetep when tested with C-8$^{+t}$ and T-2$^{+t}$, respectively.espectively.

  • PDF

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

A study on ice-slurry production by water spray (수분무에 의한 아이스 슬러리 생성에 관한 연구)

  • Kim, B.S.;Lee, Y.P.;Yoon, S.Y.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.134-143
    • /
    • 1997
  • A theoretical and experimental study has been performed to investigate the characteristics of ice-slurry product. By diffusion-controlled model, the possibility of ice slurry has been theoretically anticipated. The water vapor evaporated from the surface of droplets is extracted continuously from the chamber by a vacuum pump. The droplet diameter was measured by silion immersed method. The ice slurry has been obtained by spraying droplets of ethylene-glycol aqueous solution in the chamber where pressure is maintained under the triple point of water. The droplet of which the diameter is $300{\mu}m$, and the initial temperature is $20^{\circ}C$, was changed into ice particle within the chamber of which the height is 1.33m.

  • PDF

Flow Characteristics of Propane Premixed Flame on AC Electric Field (교류 전기장 인가에 따른 프로판 예혼합 화염의 유동 특성)

  • Boyun Kim;Minseok Kim;Taehun Kim;Ilsong Kweon;Hyemin Kim
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • This study investigates the flow characteristics of propane-air premixed flames on AC electric field using the Schlieren method. A voltage was applied to the ring electrode and the burner was grounded to form an electric field, and the applied voltage was fixed at 16 kV (Vpp). Results show that under the application of AC electric fields, flow around the flame oscillated only at frequencies below 50 Hz, and no oscillation was observed above this frequency range. Flame height oscillated with frequency in the range of 25 to 300 Hz, with frequency doubling observed in the range of 25 to 150 Hz. The flammability limit increased with frequency up to 250 Hz, but in the high-frequency range above 250 Hz, the flammability limit did not increased and converged.

Design of Helical Ribbon Type Impeller for Agitation Using CFD Analysis (전산유동해석을 활용한 헬리컬 리본형 교반기 임펠러 설계)

  • Yun, Jeong-Eui
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.15-20
    • /
    • 2019
  • The agitator is an important industrial instrument widely used for mixing various solutions in the industrial field. In this study, the optimized design of the helical ribbon type impeller, which is mainly used for the stirring of the high viscosity solution, is carried out by CFD analysis. For this purpose, an index for evaluating the agitation performance is newly defined and an optimization design process is performed through a multiphase computational fluid dynamic analysis. From these results, it is understood that the stirring performance is maximized in the case of the helical ribbon impeller under given operating conditions when the width is 7.5 mm, the height is 160 mm and the turn is 1.

Application of High-temperature 3-phase Equilibrium Distribution to Dry Scrubber for the Simultaneous Removal of $SO_2$ and Vinyl Chloride (건식세정기에서의 오염물 동시제거를 위한 고온3계평형 모델의 적용과 예비설계에의 응용)

  • 구자공;백경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.85-96
    • /
    • 1990
  • Simultaneous removal efficiencies of hydrophilic and hydrophobic gaseous pollutants are experimentally determined, and the macroscopic removal mechanism of pollutants in a dry scrubber is analyzed using the extended model of three phase equilibrium distribution of pollutant at high temperatures that can describe the different morphological conditions of adsorbent and water at varying relative humidities. For the simplicity, the inside of spray dryer is divided into three regions of ; (1) absorption, (2) three-phase equilibrium, and (3) adsorption, and the removal efficiencies of each pollutants at three regions are observed at different experimental conditions to estimate the effects of important parameters of dry scrubber. The laboratory experiments simulate the three regions of spray dryer with the temperature control and thus evaporation rate of water from the slurry particle. $SO_2$ as a hydrophilic gaseous pollutant and vinyl chloride as a hydrophobic toxic gas are selected for the future field application to soid waste incineration, and the two types of slurry are made of the two sorbents ; 10 wt.% $Ca(OH)_2$, and 10 wt.% NaOH. Result of temperature effect shows the height of absorption plus three-phase region is decreased as the operation temperature is increased, which results in the lower removal efficiency of $SO_2$ but higher removal for vinyl chloride in the adsorption region of dry scrubber. The removal efficiency of $SO_2$ is higher by NaOH slurry than by $Ca(OH)_2$ slurry due to the hygroscopic nature of NaOH, while the removal of vinyl chloride is higher in $Ca(OH)_2$ case. From the analysis of redults using three-phase equilibrium distribution model, the effective two-phase partition coefficients can be obtained, and the possible extention in the application of the three-phase equilibrium model in a dry scrubber design has been demonstrated.

  • PDF

Spray Characteristics of Jet According to Position of Injector Hole in Crossflow (횡단유동내 인젝터 홀의 위치에 따른 제트의 분무 특성)

  • Choi, Myeung Hwan;Shin, Dong Soo;Radhakrishnan, Kanmaniraja;Son, Min;Koo, Jaye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.88-96
    • /
    • 2018
  • Effects of injector position and momentum flux ratio on a vertical jet in a cross-flow field are qualitatively studied and displayed using air and water. The position of the injector hole and the momentum flux ratio is changed and image visualization is performed using a shadowgraph technique and a high-speed camera. The visualized images are compared to find differences in spraying using density gradient magnitude image. It is observed that, as the x/d of the apparatus increases, the jet break-up height decreases. When x/d is 0, the spray reaches the bottom and ceiling at any momentum flux ratio.

Effects of Replacing Spray Dried Porcine Plasma with Solpro500 on Performance, Nutrient Digestibility and Intestinal Morphology of Starter Pigs

  • Lai, C.H.;Qiao, S.Y.;Li, Defa;Piao, X.S.;Bai, L.;Mao, X.F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.2
    • /
    • pp.237-243
    • /
    • 2004
  • The objective of this study was to evaluate Solpro500 (a wheat hydrolysate containing a high level of glutamine) as a replacement for spray dried porcine plasma (SDPP) in diets fed to nursery pigs. One hundred and eight pigs (Dalland, $5.39{\pm}0.80$ kg BW) weaned at 21 days were assigned to one of three treatment groups for a 28 day feeding trial. The experimental diets were based on corn and soybean meal and were supplemented with either 8% SDPP, 4% SDPP plus 4% Solpro500 or 8% Solpro500. Each treatment was fed to six pens with six pigs per pen (4 barrows and 2 gilts). The experimental results indicated no significant difference (p>0.05) in daily gain, feed intake or feed efficiency for pigs fed the three experimental diets. However, the diarrhea index for pigs fed either 4% SDPP and 4% Solpro500 or 8% Solpro500 was lower (p<0.05) than that for pigs fed 8% SDPP. No differences (p>0.05) were found in the apparent fecal digestibility of dry matter, organic matter or crude protein between pigs fed the three diets. The intestinal morphology (villous height, villous width and crypt depth) was not affected by diet treatments (p>0.05). In conclusion, Solpro500 SDPP can replace SDPP without any negative effects on nursery pig performance.