• 제목/요약/키워드: Heel Point

Search Result 46, Processing Time 0.026 seconds

Effects of Shoe Heel-Heights on the Foot Comfort (구두의 굽높이가 발의 쾌적감에 미치는 영향)

  • Kim Hyo Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 1986
  • This paper is concerned with the mutual relationship among interpressure, last. foot within a new shoe and foot within a fifty-hour-used shoe at the standing posture at three different heel-heights 1. The interrelationship between the heel-heights and interpressure is very significant at the level of $0.1\%$. The heel-heights cause high interpressure at different parts of foot; heel point and big toe point in a 3 cm-heel shoe, big toe point and heel outside joint point in a 5 cm-heel shoe, and little toe point, heel-outside joint point, and arch point in a 7 cm-heel shoe. 2. Foot girth and foot width measurements either within a new shoe or within a fifty-hour-used shoe significant at the level of $5\%,\;1\%,\;0.1\%$ and show discrepancies at three different heel heights; the part between instep and ball joint in a 3 cm-heel shoe, toe part in a 5 cm-heel shoe, heel-inside joint. heel-outside joint and toe part in a 7 cm-heel shoe are highly influenced by heel heights. The higher the shoe-hee15 are, the more heavily the fore part of foot is pressured in lateral direction because shoe is made to have high instep from a fashion viewpoint. Higher shoe heels prevent weight pressure from being concentrated on heel. If shoe heels are toe high, people in such shoes feel easily tired. It is very worthy of note in selecting shoes to consider not only the shoe fashion but also fore shoe type, heel height, and shoe material with proper elasticity.

  • PDF

Analysis About How Human Foot Move During Driving Condition (중형승용차 운전 중 발거동 분석)

  • Park, Bo-Hyun;Jung, Hee-Seok;Lee, Sung-Hwan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.1
    • /
    • pp.41-45
    • /
    • 2012
  • Until now, most studies of foot moving or driving posture have been performed under laboratory driving conditions. But there are many different things between actual driving conditions and laboratory driving conditions because, in laboratory conditions, it is hard to consider vehicle's noise, vibration and people's psychology state while driving. Thus this study is performed through actual driving conditions. And while driving test, we recorded driver's foots with 2 cameras to investigate foots(left and right) heel point and how human foots move to control the three pedals : accel, brake and footrest.. Through driving test, the results of this study show that the position of driver's heel point isn't related to stature and tends to be generalized.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

Automatic NC-Date Generation Method for 5-axis Cutting of Turbine-Blades by Finding Safe Heel-Angles and Adaptive

  • Piao, Cheng-Dao;Lee, Cheol-Soo;Cho, Kyu-Zong;Park, Gwang--Ryeol
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.753-761
    • /
    • 2004
  • In this paper, an efficient method for generating 5-axis cutting data for a turbine blade is presented. The interference elimination of 5-axis cutting currently is very complicated, and it takes up a lot of time. The proposed method can generate an interference-free tool path, within an allowance range. Generating the cutting data just point to the cutting process and using it to obtain NC data by calculating the feed rate, allows us to maintain the proper feed rate of the 5-axis machine. This paper includes the algorithms for: (1) CL data generation by detecting an interference-free heel angle, (2) finding the optimal tool path interval considering the cusp-height, (3) finding the adaptive feed rate values for each cutter path, and (4) the inverse kinematics depending on the structure of the 5-axis machine, for generating the NC data.

Feasibility Study of Gait Recognition Using Points in Three-Dimensional Space

  • Kim, Minsung;Kim, Mingon;Park, Sumin;Kwon, Junghoon;Park, Jaeheung
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.124-132
    • /
    • 2013
  • This study investigated the feasibility of gait recognition using points on the body in three-dimensional (3D) space based on comparisons of four different feature vectors. To obtain the point trajectories on the body in 3D, gait motion data were captured from 10 participants using a 3D motion capture system, and four shoes with different heel heights were used to study the effects of heel height on gait recognition. Finally, the recognition rates were compared using four methods and different heel heights.

Study of Ultrasound Imaging Technique for Diagnosing Osteoporosis (골다공증 진단을 위한 초음파 영상화 진단 기법 연구)

  • Kim, H.J.;Han, S.M.;Lee, J.H.;Lee, M.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.386-392
    • /
    • 2002
  • Ultrasonic has been proposed as an attractive means of detecting bone loss. There have been several commercial ultrasound devices developed for measuring the heel to predict fracture at other bones. However, these devices select only single point of heel bone as measurement site. It causes poor assessment of bone quality due to the error of transducer positioning. In an effort to improve current ultrasound systems, we evaluated the linear scanning method which provides better prediction of bone quality and an accurate image of bone shape. The system used in this study biaxially scans a heel bone using automated linear scanning technique. The results demonstrated that the values of ultrasound parameters varied with different positions within bone specimen. It has been also found that the linear scanning method could better pre야ct bone quality, eliminating the error of transducer positioning.

A Comparative Study on the Characteristics of Friction with/without shoes by Analyzing Bio-signals during walking (보행 시 생체신호분석을 통한 신발 착용 유무에 따른 마찰 특성 비교)

  • Oh, Seong-geun;Kim, Jin-Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.59-66
    • /
    • 2018
  • The utilized coefficient of friction (UCOF) as a ratio of the shear force to the normal force on the ground during walking is used to identify the point at which slip is likely to occur. Shoe walking will change the utilized coefficient of friction by shoe design such as sole thickness and hardness, heel shape, and outsole pattern. In this study, subjects are 21 adults (10 female, 11 male, age: $25.2{\pm}2.3yrs$, height: $165.6{\pm}7.2cm$), analysis variables were walking speed, GRF, when the UCOF is maximal, and Tangent of CoP-CoM angle, and correlation analysis with the utilized friction coefficient (UCOF). As a result, First, for the shod walking the time point which UCOF is maximum about heel strike was faster and the magnitude was larger than for barefoot walking. Second, the correlation between the tangent of CoP-CoM and UCOF of right foot was higher at the left heel striking point (UCOF2_h) which occurred in the post propulsion phase than at the right heel striking point (UCOF1_h). This suggests that the right foot UCOF is related to the braking phase of left foot( which is the propulsion phase of right foot) rather than the braking phase of right foot.

Reconstruction for the Soft Tissue Defect of Heel using Free Lateral Arm Neurosensory Flap (유리 외측 상박 감각신경 피판술을 이용한 종부 연부조직 결손의 재건)

  • Kim, Dong-Churl;Kim, Sang-Soo;Ha, Dae-Ho;Yoo, Hee-Jun;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.15-21
    • /
    • 1999
  • Soft tissue defect on heel area of the foot present difficult problems particularly because of anatomic property of plantar surface of the foot. There is a paucity of available local tissue in the foot for coverage. In addition to having little expandable tissue, the foot's plantar surface has a unique structure, making its replacement especially challenging. Plantar skin is attached to the underlying bone by fibrous septa, preventing shear of the soft-tissue surfaces from the underlying skeleton. Plantar surface of foot is in constant contact with the environment. Protective sensibility also would be maintained or restored in the ideal reconstruction. So the ideal flap for reconstruction of the heel should include thin, durable hairless skin with potential for reinnervation. The aim of this article is to present a clinical experience of free lateral arm neurosensory flap for reconstruction of the heel. From March 1995 to December 1997, a total 16 lateral arm free flaps were performed to soft tissue defects on the weight-bearing area of the hindfoot. we used tibial nerve as recepient nerve in 11 and calcaneal branch of tibial nerve in 5 for restoration of sensibility of flap. All cases survived completely. A static two-point discrimination of 14 to 34mm was detected in the flap. Radial nerve palsy which was caused by hematoma in donor site occured in one case, but recorverd in 3 weeks later completely. In conclusion, the lateral arm free flaps are versatile, reliable and sensible cutaneous flap and especially indicated for soft tissue defect on plantar surface of the hindfoot which are not good indications for other better-known flaps.

  • PDF

A Review on the Absence of Accumulation Point in the Governer, Conception, Thoroughfare, Belt Vessel of Extra Meridian (기경팔맥 중 독맥, 임맥, 충맥, 대맥에 극혈이 없는 이유에 대한 연구)

  • Lee, Bong Hyo;Park, Ji Ha;Kim, Hee Young;Kim, San Deul;Yang, Hyun Dong;Lee, Ho Jung;Choi, Jae Won;Lim, Sung Chul;Kim, Jae Su;Lee, Yun Kyu;Lee, Hyun Jong;Jung, Hyun Jung;Jung, Tae Young
    • Korean Journal of Acupuncture
    • /
    • v.30 no.2
    • /
    • pp.81-87
    • /
    • 2013
  • Objectives : Accumulation point is a useful acupoint for acute pain diseases. Among the eight extra meridians, only four (Yin Heel, Yang Heel, Yin Link, Yang Link vessel) have accumulation point and the others (Governor, Conception, Thoroughfare, Belt Vessel) do not. However, there is no explanation why these four meridians do not have it. So, the authors researched the literature to look for the reasons. Methods : We investigated 10 books and 1 paper about the 'accumulation point of extra meridians' using several search engines and researched reason why the other 4 meridian do not have it. Results : All of the 16 accumulation points are located on the 4 limbs. The four limbs have more Yang energy than the trunk. The governor, conception, thoroughfare, and belt vessels do not flow in the limbs. It seems that there is no acupoint located on deep gap enough to be the accumulation point among the four vessels. When it comes to the functions of these vessels, they are little related with the acute pain that is the main target of the accumulation point. Conclusions : From the results of this study, it seems to be reasonable that the four vessels do not have accumulation point.

Design Consideration of Optimal Seating Package by Generating Korean Manikins (한국형 마네킨 구현에 의한 최적 시팅 패키지 설계 치수 제안)

  • Lee, Yeong-Sin;Park, Se-Jin;Nam, Yun-Ui;Song, Geun-Yeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.57-69
    • /
    • 1999
  • The primary objective of this research was to suggest the design dimensions of automotive seating package that has an important effect upon seating package design. To conduct the research, a set of manikin dimensions that are representative for Korean was determined by using a statistical scheme. With these dimensions, we generated nine manikins for male and female, respectively. Also, the preferred driving posture was investigated using the experimental setup. To find each joint angle for subjects, a driving monitoring system was developed and a three dimensional motion analysis system was employed. The joint angle for the subject was established and compared with related literature. With the generated manikins and each joint angle, the driving posture was simulated by using SAFEWORK that is a program to generate manikins. The positions and adjustable ranges from the accelerator heel point to the hip point and the steering wheel center point that are important variables in order to design seating package were suggested. Further research is needed to determine the seating package dimensions three dimensionally.

  • PDF