• 제목/요약/키워드: Heavy-weight Noise

검색결과 160건 처리시간 0.022초

중량바닥충격에 의한 소음 및 진동 특성 (Noise and Vibration Characteristics by Heavy-weight Floor Impact)

  • 서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.919-922
    • /
    • 2003
  • The correlation between noise and vibration by a heavy-weight floor impact was studied. The triggering technique was used for increasing the reliability and stability to measure the level of sound pressure, sound intensity and vibration acceleration. The simple finite element and rigid body analysis method were suggested to calculate the natural frequencies of the multi-layer floor system. The result show that the isolation material adapted to reduce the light-weight floor impact noise, causing the natural frequency lower, make resonance with dominant driving frequency, and increase the noise level very sharply. Therefore the noise level Peak in the region of low frequency, below 63Hz, would be related with the natural frequencies of the floor system.

  • PDF

표준실험동에서 중량충격음의 방사 특성 (Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building)

  • 유승엽;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구 (Noise control of a slab using the laminated composite damping system)

  • 황재승;김광용;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구 (Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources)

  • 유승엽;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

슬래브 진동모드의 바닥충격음 기여특성에 관한 연구 (Contribution of the Mode Vibration to Heavy Weight Floor Impact Noise)

  • 황재승;박홍근;문대호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.159-160
    • /
    • 2014
  • The floor impact noise arising between upper and lower households in residential houses has been known as one of major causes worsening residential environment and still led to serious social troubles in a residential community. It is known that the heavy weight floor impact noise is induced by flexural vibration modes in the relatively lower frequency ranges. In this study, a procedure is examined to evaluate the relations between the vibration modes and the corresponding noise of the slab. In the process, for simplicity of the numerical analysis, it is assumed that the slab is simply supported plate-like structure and the acoustic mode formed in the lower room by acoustic boundary conditions is ignored.

  • PDF

노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구 (A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses)

  • 주문기;한명호;오양기
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

공동주택 이중바닥구조의 바닥충격음 저감성능 (Floor Impact Noise Reduction Performance of Double-Floor System in Apartments)

  • 백길옥;박홍근;문대호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.197-202
    • /
    • 2014
  • Floor Impact Noise is a structure-borne noise which is mainly caused by vibration of concrete slabs. The majority of previous studies have focused on investigating performance of absorbing sheets on the reduction of floor impact noise. But absorbing sheets do not efficiently reduce heavy-weight floor impact noise level because it cannot absorb slab vibration, which is the fundamental noise source. In this study, double-floor system was developed in order to reduce floor impact noise level in residual buildings. This floor system reduces heavy-weight impact noise level by reducing vibration response at the center of slab, which has maximum amplitude in the 1st vibration mode. In order to identify the performance of the double-floor system, experiments were planned. Primary test parameters are span of double floor, arrangement and types of absorbing sheets.

  • PDF

Annoyance 반응에 의한 중량충격음 평가척도 구성 (Establishing Evaluation Modifiers for the Annoyance Responses to Heavyweight Impact Noise)

  • Kim, Kyoung-Ho;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.917-917
    • /
    • 2003
  • The auditory experiments based on the subjective annoyance responses were undertaken for the establishment of the adverb modifiers of the heavy-weight impact noises. The standard heavy weight impact noise, impact ball noise and adult walking noise were recorded by dummy head at a newly-built apartment and were presented to the subjects by headphones. The levels of the three impact noises were varied from 30 to 60㏈(A) and the subjects matched one of the adverb modifiers to each level of the noise sources. As a result, seven scale modifiers were established and the intervals between the modifiers were found as equal. In addition, it was found that the lower annoyance noise limits for the heavyweight impact, impact ball and walking were 40-45㏈ (L$\sub$I, Fmax. AW), which is 6㏈ lower than in the previous study. The background noise level was as low as 21㏈(A) in the test booth, therefore, the testing conditions need to be concerned for evaluation of floor impact noise.

  • PDF

공동주택의 중량충격음 저감을 위한 제진재의 활용 (Use of Damping Materials for Reducing Heavyweight Floor Impact Noise in Apartment Buildings)

  • 정영;유승엽;김민배;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.96-99
    • /
    • 2005
  • Noise and vibration generated by heavy-weight floor impact in apartment buildings were studied. The resonance frequency increased in the floor structures where damping materials were used in the living room and the bedroom. Both the acceleration wavelength and the acceleration level decreased. The results showed that the resonance frequency increased and vibration acceleration level decreased when the damping materials were used. Heavy-weight impact sound levels of the structure decreased substantially below 80Hz.

  • PDF

슬래브 두께에 따른 표준실험동의 중량충격음 특성 (Heavy-weight Floor Impact Sound Characteristics of Standard Laboratory by Slab Thickness)

  • 정영;송희수;전진용;김진수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.103-108
    • /
    • 2004
  • In this study, examined heavy-weight floor impact sound to structure that have slab thickness of 4 form at a standard laboratory through noise and vibration measured. The results show that the nature Natural frequency increased according to change of thickness of each slab by finite element analysis, and acceleration value decreased. Results of measurements of noise and vibration at a standard laboratory, the slab 210, 240mm structures was construed result such as finite element analysis but the slab 150, 180mm structures is construed that influence in vibration acceleration level because edge condition has condition that contact to ground. Therefore, in modelling process for analysis, is thought that need that condition analyzes examining element influencing about structure that contact to ground.

  • PDF