• 제목/요약/키워드: Heavy ion

검색결과 595건 처리시간 0.034초

A calculation on the Metal-Film Mixing by Intense Pulse Ion Beam (IPIB)

  • Le, X.Y.;Yan, S.;Zhao, W.J.;Wang, Y.G.;Xue, J.M.
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.74-78
    • /
    • 2003
  • In this paper, we studied, by numerical calculation, a system, which was composed of metal-film and metal-substrate irradiated by IPIB with beam ion energy 250 keV, current density 10 to 250 A/$\textrm{cm}^2$. While the IPIB irradiation was going on, an induced effect named mixing occurred. In this case, metal-film and part of metal-substrate melted and mixed. The mixing state was kept as it was in melting phase due to the fast cooling rate. Our works were simulating the heating and cooling process via our STEIPIB program and tried to find proper parameters for a specific film-substrate system, 500 nmtitanium film coated on aluminum, to get best mixing results. The parameters calculated for such Ti-Al system were compared with the experimental results and were in good accordance to the experimental results.

도시고형폐기물 소각비산재의 Electrokinetic 정화

  • 조용실;한상재;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.224-227
    • /
    • 2001
  • In general, municipal solid waste incinerator fly ash (MSWIF) has a potential hazardous leaching of heavy metal with subsurface environment variation. Therefore, to remove the heavy metal from MSWIF electrokinetic technology were used. With constant current density condition heavy metals in MSWIF removed by ion migration. During 7 days operation 40~80% of Cr, Cd and As were removed and longer operation, 14 days treatment, showed 35~100% removal efficiency.

  • PDF

BOD 測定에 影響을 미치는 重金屬이온에 關한 연구 (Study of the Influence of Heavy Metal Ions(Cu, Cr, Pb, Zn) on Biochemical Oxygen Demand)

  • Choi, Taek-Pyul;Yun, O-Sub
    • 한국환경보건학회지
    • /
    • 제9권2호
    • /
    • pp.75-81
    • /
    • 1983
  • The Biochemical Oxygen Demand(BOD) indicates that microbes are proliferating or that oxygen is being spent by breathing action when examining water under the same aerobic condition. In this research of the mesurement of BOD are the poisonous elements of heavy metal ions such as Cu-ion, Cr-ion, Pb-ion and Zn-ion. They exert an unfavorable influence in the analysis of BOD and research was performed to provide certain data of minimum negative influence by the poisonous matters. The results of the research confirm that heavy metal ion(Cu, Cr, Pb, Zn) do direct an influence upon the normal growth of aerobic microbes in actual tests of chemical analysis of portable water or sewage. The most critical concentration for a negative effect on lowering oxygen quantity and disturbing the aerobic mocrobes normal growth was found to be 0.01 mg/l. Therefore, test results are not valid if the heavy metal concentration is to or greater than 0.0mg/l, To improve comprehension through out the research the author uses the following abbreviations: 1. The Cu-ion is to be excluded before experimental analysis if it is over 0.01mg/l inorder to obtain a real value for the BOD. 2. The Cr-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 3. The Pb-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 4. The Zn-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD.

  • PDF

폐종이컵을 이용한 이온교환체 제조와 중금속제거특성 (Preparation of ion exchanger from waste paper cup and removal characteristics of heavy metal)

  • 유수용;이훈용;정원진;문명준;이민규
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.993-999
    • /
    • 2002
  • Waste paper cup was sulfonated to be used as ion exchanger. Removal characteristic of copper and lead ion by prepared ion exchanger was investigated. The sulfonation was conformed by the high intensity band of $SO_3H$ group around 1100~$1160cm^{-1}$. The synthesized ion exchanger had greater removal ability for copper and lead ion than the original waste paper cup. Ion exchange system reached the final equilibrium plateau within 30min. The maximum removal capacities $q_{max}$ were calculated as 9.79mg/g fur copper and 15.95mg/g for lead, respectively. The affinity of lead based on a weight was higher than that of copper. The ion exchange phenomena appeared to follow a typical Freundlich isotherm.

Localization of Ultra-Low Frequency Waves in Multi-Ion Plasmas of the Planetary Magnetosphere

  • Kim, Eun-Hwa;Johnson, Jay R.;Lee, Dong-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권4호
    • /
    • pp.289-295
    • /
    • 2015
  • By adopting a 2D time-dependent wave code, we investigate how mode-converted waves at the Ion-Ion Hybrid (IIH) resonance and compressional waves propagate in 2D density structures with a wide range of field-aligned wavenumbers to background magnetic fields. The simulation results show that the mode-converted waves have continuous bands across the field line consistent with previous numerical studies. These waves also have harmonic structures in frequency domain and are localized in the field-aligned heavy ion density well. Our results thus emphasize the importance of a field-aligned heavy ion density structure for ultra-low frequency wave propagation, and suggest that IIH waves can be localized in different locations along the field line.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

HCl 용액에서의 중금속 이온, $Cd^{2+}$-$Cl^{3+}$-$Pb^{2+}$의 흡착 특성 (Adsorption Property of Heavy Metal ion, $Cd^{2+}$-$Cl^{3+}$-$Pb^{2+}$+ in HCI Solution)

  • 박원우;이봉헌
    • 한국환경과학회지
    • /
    • 제5권6호
    • /
    • pp.779-783
    • /
    • 1996
  • Cation exchange distribution coefficients of poly(dithiocarbamate) were presented for $Cd^{2+}$, $Cr^{3+}$, and $Pb^{2+}$ in HCI. The distribution coefficients were determined tv using the batch method. Based on these distribution data, the separation possibilities of the heavy metal ions were discussed. The distribution coefficients of three heavy metal ions on dithiocarbamate resin were decreased as HCI concentrations were increased. The selective separation of $Cr^{3+}$ and $Cd^{2+}$ was possible by using 0.1M HCl in dithiocarbamate resin and the reproducibility test showed that the average absorptivity of resin was 90% in the case of $Cd^{2+}$ ion by the column method.

  • PDF

Design study of the Vacuum system for RAON accelerator using MonteCarlo method

  • 김재홍;전동오
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.70.1-70.1
    • /
    • 2015
  • The facility for RAON superconducting heavy-ion accelerator at a beam power of up to 400 kW will be produced rare isotopes with two electron cyclotron resonance (ECR) ion sources. Highly charged ions generated by the ECR ion source will be injected to a superconducting LINAC to accelerate them up to 200 MeV/u. During the acceleration of the heavy ions, a good vacuum system is required to avoid beam loss due to interaction with residual gases. Therefore ultra-high vacuum (UHV) is required to (i) limit beam losses, (ii) keep the radiation induced within safe levels, and (iii) prevent contamination of superconducting cavities by residual gas. In this work, a RAON vacuum design for all the accelerator system will be presented along with Monte Carlo simulation of vacuum levels in order to validate the vacuum hardware configuration, which is needed to meet the baseline requirements.

  • PDF

Ionic Strength 및 공존(共存) 음(陰)Ion이 Zeolite에 의(依)한 중금속(重金屬)의 흡착(吸着)에 미치는 영향(影響) (Effects of Ionic strength and Anion species on Heavy Metal Adsorption by Zeolite)

  • 이정재;박병윤;최정
    • 한국환경농학회지
    • /
    • 제7권2호
    • /
    • pp.96-101
    • /
    • 1988
  • Ionic strength 및 공존(共存) 음(陰)Ion($Cl^-$, $SO^{2-}\;_4$, $ClO^-\;_4$)이 Zeolite에 의(依)한 중금속(重金屬)의 흡착(吸着)에 미치는 영향(影響)을 조사(調査)한 결과(結果)는 다음과 같다. Ionic strength별(別) Zeolite에 의(依)한 Cd, Cu 및 Zn의 흡착등온선(吸着等溫線)은 Freundlich 식(式)에 잘 부합(符合)되었다. Ionic strength가 증가(增加)할수록 중금속(重金屬)의 흡착량(吸着量)은 3종(種)의 서로 다른 음(陰)Ion이 공존(共存)하여도 모두 감소(減少)하는 경향(傾向)이었다. Background salt의 음(陰)Ion 종류별(種類別) 중금속(重金屬) 흡착량(吸着量)은 $ClO^-\;_4>SO^{2-}\;_4>Cl^-$의 순(順)이었으며 흡착평형용액내(吸着平衡溶液內)에서 음(陰)Ion은 Ligand로 작용(作用)하여 중금속(重金屬) Ion들과 Complex를 형성(形成)하는 능력(能力)에 차이(差異)가 있음이 인정(認定)되었다.

  • PDF

저압나노여과에 의한 각종 중금속의 제거 특성 (Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration)

  • 오정익;김한승;김충환
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.