• Title/Summary/Keyword: Heavy Metal ions

Search Result 504, Processing Time 0.025 seconds

Leaching of Iron and Aluminum from Red Mud and Preparation of Coagulants (적니로부터 철과 알루미늄의 침출 및 응집제의 제조)

  • Lee, Jae-Rok;Hwang, In-Gook;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.15 no.1
    • /
    • pp.38-41
    • /
    • 2009
  • Red mud is generated as a waste byproduct during the production of aluminum hydroxide/alumina from bauxite ore in the Bayer process. In this study coagulants for wastewater treatment were prepared by leaching iron and aluminum from red mud with hydrochloric acid. The removal efficiency of heavy metal ions by the red mud coagulant increased with increasing the adjusted pH value of the synthetic wastewater. When the red mud coagulant was prepared, the leaching efficiency of Fe decreased with increasing the weight of red mud, while the pH value of the red mud coagulant increased. The solution of the red mud coagulant mixed with water was reacted again with red mud to produce the leached solution, which had higher concentrations of Fe and Al and a higher pH value than the red mud coagulant. Also, its pH value was comparable to that of other coagulants: $FeCl_3$ and $Fe_2(SO_4)_3$.

Adsorption of heavy metal ions onto a surface treated with granular activated carbon and activated carbon fibers (표면 처리에 따른 입상활성탄 및 활성탄소섬유의 중금속 흡착)

  • Kang, Kwang Cheol;Kwon, Soo Han;Kim, Seung Soo;Choi, Jong Won;Chun, Kwan Sik
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.285-289
    • /
    • 2006
  • In this study, the effect of an acidic treatment on granular activated carbon (GAC) and activated carbon fibers (ACF) was investigated for a $Pb^{2+}$ and $Ni^{2+}$ ion adsorption. 1.0 M nitric acid solution was used as the acid solution for the surface treatment. Surface properties of the GAC and ACF were characterized by the pH, elemental analysis and pHpzc (pH of the point of zero charge). Their specific surface area and the pore structure were also evaluated by the nitrogen adsorption data at 77K. As a result, the acidic treatment led to an increase of the oxygen-containing functional groups. Furthermore, the adsorption capacity of the acid-treated GAC and ACF was improved in the order of acidic-ACF > untreated-ACF > acidic-GAC > untreated-GAC, though the decrease in specific surface area induced by a pore blocking of the functional groups was observed.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (I): Evaluation of Acid Stability of Commercial Nanofiltration Membranes (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(I): 상용 나노여과 막의 산 안정성 평가)

  • Youm, Kyung-Ho;Shin, Hwa-Sup;Jin, Cheon-Deok
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • In this study the nanofiltration (NF) membrane treatment of a nitric acid waste solutions containing $Pb^{+2}$ heavy metal ion discharging from the etching processes of an electronics and semiconductors industry has been studied for the purpose of recycling of nitric acid etching solutions. Three kinds of NF membranes (General Electric Co. Duraslick NF-4040 membrane, Dow Co. Filmtec LP-4040 membrane and Koch Co. SelRO MPS-34 4040 membrane) were tested for their separation efficiency (total rejection) of $Pb^{+2}$ ion and membrane stability in nitric acid solution. NF experiments were carried out with a dead-end membrane filtration laboratory system. The membrane permeate flux was increased with the increasing storage time in nitric acid solution and lowering pH of acid solution because of the enhancing of NF membrane damage by nitric acid. The membrane stability in nitric acid solution was more superior in the order of Filmtec LP-4040 < Duraslick NF-4040 < SelRO MPS-34 4040 membrane. The total rejection of Pb+2 ion was decreased with the increasing storage time in nitric acid solution and lowering the pH of acid solution. The total rejection of $Pb^{+2}$ ion after 4 months NF treatment was decreased from 95% initial value to 20% in the case of Duraslick NF-4040 membrane, from 85% initial value to 65% in the case of SelRO MPS-34 4040 membrane and from 90% initial value to 10% in the case of Filmtec LP-4040 membrane. These results showed that SelRO MPS-34 4040 NF membrane was more suitable for the treatment of an acidic etching waste solutions containing heavy metal ions.

Physicochemical Heterogeneity of the Supply Water Quality depending on Seasonal Changes in the Taejon Area, Korea (대전지역 상수도 물의 계절변화에 따른 물리화학적 불균질)

  • 이현구;이찬희;서호택
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.505-517
    • /
    • 2000
  • This study was undertaken to provide a drinking water quality on the basis of physicochemical properties. In this study, the 25 samples of supply waters of the Taejon area were sampled twice (February and August in 1999). Hydrochemistry of the supply water belongs to the $Ca^{2+}$-${HCO_3}^{-1}$ type, whereas the supply water was characterized by the relatively significant enrichment of ${Ca}^{2+}$, ${Na}^{2+}$, ${K}^{2+}$, ${Cl}^{2+}$ ions and heavy metals compared to the original water from the Daecheong lake. Generally, the supply water has a mean values for $10.7^{\circ}C$ of temperature, 6.86 of pH, -12 mV of Eh, 88 ${\mu}S$/cm of EC and 70.379 mg/l of TDS in February, whereas the waters of the same sites in August are a slightly high temperature ($26.1^{\circ}C$), TDS (78.069 mg/l) and extremely high EC (442 ${\mu}S$/cm) value. These values are similar with physicochemical properties of the original lake water depending on the seasonal differences. Results of speciation calculation indicate that potentially toxic ions might exist mainly in the forms of free metal (${Cu}^{2+}$ or ${Zn}^{2+}$) and a small amount of ${CO_3}^{2-}$and ${OH}^{-}$in the supply water. The water seemed to be in equilibrium with kaolinite field of the normal stability diagrams for the natural water. Based on enrichment parameter of the supply water normalized by original lake water composition, the average value of those parameter can be calculated with nearly 1.00, but the those values for Cu+Zn possible source of decrepit pipe lines are 126.75 in February and 115.63 in August samples. The parameter values varied with sampling sites, however, do not exceed by chemistry of drinking water standard. Solid compounds remained on the membrane filter papers after filtration are adhered to pale yellow or yellowish brown colored dissolved solids and precipitates, which are coated by 0.02 to 0.35 mm thick per 500 ml with colloidal particles of about 1 to 2${\mu}m$ size. The particles are mainly Fe-Cu-Zn compounds and partly detected to Mn and Pb.

  • PDF

Preparation of Acrylic Acid Grafted Polypropylene by Electron Beam Irradiation and Heavy Metal Ion Adsorption Property (전자선 조사를 이용한 아크릴산이 그라프트된 폴리프로필렌의 제조 및 중금속 이온 흡착 특성)

  • Cheon, Ja young;Jeun, Joon-pyo
    • Composites Research
    • /
    • v.32 no.6
    • /
    • pp.335-341
    • /
    • 2019
  • In this study, an acrylic acid (AAc) was grafted on a polypropylene (PP) nonwoven fabric using electron beam irradiation. Electron beam grafting was carried out under various conditions to produce AAc grafted PP (PP-g-AAc) nonwoven fabric having a grafting yield of about 50% at radiation dose of 100 kGy and a monomer concentration of 60%. The physical and chemical properties of PP-g-AAc nonwoven fabric were evaluated by SEM, ATR-FTIR, thermal analysis and tensile strength. The morphology of PP and PP-g-AAc nonwoven fabric confirmed by SEM showed no significant change, and it was judged that AAc was introduced into PP nonwoven fabric from ATR-FTIR. PP-g-AAc nonwoven fabric showed an increase in tensile strength and a decrease in tensile strain compared to PP nonwoven fabric. However, since change of value is not significant, it is considered that there is no significant influence on the physical characterization. Adsorption experiments of PP-g-AAc nonwoven fabric on various ions showed selective adsorption behavior for lead ion. In conclusion, the electron beam radiation-induced PP-g-AAc nonwoven fabric is expected to be applied as an effective adsorbent for the adsorption of lead ions.

Studies on the Determination of Heavy Metal Ions by Flow Injection, the Photochemical Characterization and Polymerization of Eight-Coordinated Complex(Part I): Spectrophotometric Determination of Uranium and Thorium Ions by Flow Injection Analysis using Chrome Azurol S in the Presence of Surfactant (금속이온의 흐름주입법에 의한 정량, 8-배위착물의 광학적 특성 및 중합체에 관한 연구(제1보): 계면활성제 존재하에서 Chrome Azurol S를 사용하여 우라늄 및 토륨이온의 흐름 주입법에 의한 분광광도 정량)

  • Chang, Choo-Hwan;Kang, Sam-Woo;Son, Byung-Chan;Cho, Kwang-Hee
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Spectrophotometric determination of U(VI) and Th(IV) by Flow injection method is described. Chrome Azurol S forms water soluble complexes with U(VI) and Th(IV) in the presence of cethyltrimethylammonium bromide. The maximum adsorption of U(VI) and Th(IV) complexes are at 600nm with molar absorptivity of $2.3{\times}10^5Lmol^{-1}cm^{-1}$ and 611nm with molar absorptivity of $3.8{\times}10^5Lmol^{-1}cm^{-1}$ in acetate buffer medium having pH 5.0 and 5.5. The calibration curves of U(VI) and Th(IV) are linear over the range of 0.1~0.8ppm and the correlation coefficients are ca. 0.9960 and 0.9930 respectively. The detection limits(S/N) are 20ppb for U(VI) and 15ppb for Th(IV). The relative standard deviation are ${\pm}1.8%$ for U(VI) and ${\pm}2.1%$ for Th(IV). The sample throughput was ca. $50hr^{-1}$.

  • PDF

Synthesis and Characterization of Zeolite Using Water Treatment Sludge (정수슬러지를 이용한 제올라이트의 합성 및 특성연구)

  • Ko, Hyun Jin;Ko, Yong Sig
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2020
  • Zeolite was synthesized hydrothermally using the water-treatment sludge, and the effects of various synthesis parameters like reaction temperature, reaction time, and Na2O/SiO2 molar ratio on the crystallization of zeolite were investigated. Crystal structure, physical property, and thermal stability of zeolite crystals were characterized by X-ray powder diffraction, FTIR spectroscopy, BET nitrogen adsorption, and TGA measurements. The removal efficiencies of nitrogen in ammonia, heavy metal ions, and TOC were calculated to evaluate zeolite's adsorption capacity. The primary chemical composition of water-treatment sludge was 28.79% Al2O3 and 27.06% SiO2. The zeolites were synthesized by merely employing the water-treatment sludge as silica and alumina sources without additional chemicals. Zeolite crystals synthesized through the water-treatment sludge were confirmed as an A-type zeolite structure. Zeolite A had the highest crystallinity obtained from a gel with the molar composition 2.1Na2O-Al2O3-1.6SiO2-65H2O after 5 h at a temperature of 90 ℃. The specific surface area of zeolite obtained was 55 ㎡ g-1, which was higher than commercial zeolite A. The removal efficiency of nitrogen in ammonia was 68% after 3 h of reaction time, while the removal efficiencies of Pb2+ and Cd2+ ions were 99.1% and 99.3%, respectively. These results indicate active ion exchange between Pb2+ or Cd2+ ion and Na+ ion in the zeolite framework. The adsorption experiments on the different zeolite addition conditions were performed for 3 h with 300 ppm humic acid. Based on the results, TOC's highest efficiency was 83% when 5 g of zeolite was added.

Removal of Cu(II) with the Recycled Hydroxylapatite from Animal Bones (동물뼈로부터 재활용된 hydroxylapatite를 이용한 Cu(II) 제거)

  • Kim, Mu-Nui;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.735-742
    • /
    • 2009
  • The bone of spinal animals has a hydroxylapatite ($Ca_{10}(PO_4)_6(OH)_2$, HAp) structure which is well known as an excellent inorganic ion exchanger for various heavy metal ions in solutions. In this study, the reusability of cow-bone, pig-bone and fish-bone as a potential material for the removal of heavy metals in solutions was evaluated from the removal of Cu(II) ion in batch tests. The surface properties of three bones, calcined at different temperatures, were measured with SEM, XRD, FT-IR analyses. From the SEM analysis, a clear development of heterogeneity as well as pores having small diameter was observed as the calcination temperature increased. The results of X-ray diffraction analysis showed well developed crystallinity on the surface of calcined bones obtained at higher temperatures, suggesting a transform of amorphous type to crystalline type. Fourier transform infrared (FT-IR) analysis showed disappearance of water molecule on the surface of HAp and organic functional groups of the HAp with increasing the calcination temperatures. Cu(II) removal in the control test was below 15%. By the way, additional 40% increase of Cu(II) removal was observed in the presence of calcined bones. For three bones, Cu(II) removal was decreased as the calcined temperature increased. Cu(II) removal was increased as the solution pH increased due to a favorable condition for the cation exchange as well as precipitation.

Studies on the Electrochemical Behaviors, Spectrophotometric Determination of Heavy Lanthanide Ions and Heavy Metal Chelate Complexes with Bidentate Ligands(III) -Synthesis and Characterization of the Tetrakis(5,7-dichloro-8-quinolinato)(2-mercaptopyrimidinato) molybdenum(IV) Complex- (무거운 란탄이온의 전기화학적 거동, 분광학적 정량 및 중금속 이온과 두 자리 리간드 착물에 관한 연구(제 3 보): -테트라키스(5,7-디클로로-8-퀴놀리나토)(2-메르캅토피리미디나토) 몰리브데늄(IV) 착물의 합성 및 특성-)

  • Chang, Choo Hwan;Choi, Won Jong;Park, Keun Su;Son, Pyung Su;Suh, Moo Yul
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.417-424
    • /
    • 1993
  • Eight-coordinate tetrakis molybdenum(IV) complexes containing 5,7-dichloro-8-hydroxyquinolinol(Hdcq) and 2-mercaptopyrimidine(Hmpd) has been prepared. $Mo(mpd)_4$, $Mo(dcq)(mpd)_3$, $Mo(dcq)_2(mpd)_2$, $Mo(dcq)_3(mpd)$ and $Mo(dcq)_4$ complexes have been isolated by thin-layer chromatography on silicagel plates. These complexes have been charaterized by $^1H-nmr$ spectrum and UV-Vis. spectrum. The chemical shift values of the protons ${\alpha}$ to the nitrogen in the ligands are shifted to down field. The relative intensities of the peaks which are positioned at the same proton of $Mo(dcq)(mpd)_3$ and $Mo(dcq)_3(mpd)$ are observed in 2:1 ratio, in case of $Mo(dcq)_2(mpd)_2$ appears in approximately a 1:1 ratio. The stereochemistry of the complexes in discussed in terms of their nmr spectrum and Orgel's rule. By vertue of the intensities (${\varepsilon}$>10,000~25,000) the low energy($16,600{\sim}19,800cm^{-1}$) bands are observed for the electronic spectra of the complexes are assigned as charge transfer bands.

  • PDF

[$Hg^{2+} $-induced Reversible Inhibitions of Microsomal $H^+-ATPase$ Prepared from Tomato Roots ($Hg^{2+}$에 의한 토마토 뿌리조직 마이크로솜 $H^+-ATPase$의 가역적 저해)

  • Shin, Dae-Seop;Cho, Kwang-Hyun;Kim, Young-Kee
    • Applied Biological Chemistry
    • /
    • v.42 no.4
    • /
    • pp.298-303
    • /
    • 1999
  • In order to characterize the effects of heavy metal ions on the microsomal ATPase activities, microsomes were prepared from the roots of tomato plant and the activity of microsomal ATPase was measured by an enzyme-coupled assay. $Hg^{2+}$ inhibited the activity of microsomal ATPase in a dose-dependent manner, while $Gd^{3+}$, $Fe^{3+}$, $La^{3+}$, $Zn^{2+}$, and $Pb^{2+}$ inhibited not only the ATPase activity but also the activities of enzymes used in the assay. However, $Cs^+$ and $Ba^{2+}$ showed no significant effect. $Hg^{2+}$ inhibited the activities of both plasma membrane and vacuolar membrane $H^+-ATPases$. In the dose-response to $Hg^{2+}$, the activities of both microsomal $H^+-ATPases$ were severely inhibited at the concentration of $Hg^{2+}$ above $10\;{\mu}M$ and were completely inhibited at 1 mM $Hg^{2+}$. Apparent Ki values of $Hg^{2+}$ on the inhibitions of plasma membrane and vacuolar membrane $H^+-ATPases$ were $80\;{\mu}M$ and $58\;{\mu}M$, respectively. The $Hg^{2+}$-induced inhibitions were reversible since the addition of dithiothreitol completely reversed the inhibitory effects of $Hg^{2+}$. These results suggest that the inhibitory effects of $Hg^{2+}$ on both plasma, membrane and vacuolar membrane $H^+-ATPases$ are nonselective and reversible.

  • PDF