The Characteristic Improvement of Inverter Output for Static UPS (UPS용 인버터 출력특성 개선)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2051-2053
    • /
    • 1998
  • In spite of nonlinear or step-changing load and line disturbances, the inverter for the UPS must provide the pure sinusoidal output voltage with low THD(Total Harmonics Distortion). This paper proposes an inverter controller for the UPS which has a good dynamic response characteristic and robustness for applying industrial world directly. The inverter output voltage is controlled instantaneously with a double regulation loop by a TMS320C31 Digital Signal Processor so that it has very good dynamic response for nonlinear or step-changing load and line disturbances. To improve the voltage utilization and response characteristics, the Space Vector Modulation(SVM) technique is adapted for the switching method of this system. The characteristics of the proposed control system were verified by simulations and experiments.

  • PDF

The Study of IEC61850 Object Models for Transformer Preventive Diagnosis (변압기 예방진단을 위한 IEC61850 객체모델에 관한 연구)

  • HwangBo, Sung-Wook;Oh, Eui-Suk;Kim, Beung-Jin;Kim, Hyun-Sung;Lee, Jung-Buk;Park, Gui-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.103-104
    • /
    • 2006
  • Since the first proposition of IEC61850 object model at 1993, many questions about making a seamless model have been issued. the reason which they have worry about is that the functions of the equipment are supposed to be changed properly and new equipment and scheme are need to be introduced according to user's application. To handle those issues, TC57 which is a IEC committee for power control and communication has continuously updated the object model. Nowadays along with the new object model involving power quality, distribution resource and wind power, the committee has a plan to announce the revision of IEC61850-7-4. In the study, authors will present the prediction and diagnosis object models for transformer. Transformer models for protection and control have already been dealt with in the international standard but the models for prediction and diagnosis have never mentioned until now. Designing the prediction and diagnosis functions with the existing IEC61850-7-4, it'll be shown what is a proper object model for prediction and diagnosis.

  • PDF

Auto-Bending Manufacturing System for Boiler Tubes (보일러 튜브 자동벤딩 생산시스템 개발)

  • Lee, Hyun-Soo;Kang, Moon-Hyun;Park, Jun-Kon;Hur, Kwan;Sung, Joon-Suk;Heo, Wang-Soon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.450-454
    • /
    • 1997
  • This system is the automatic boiler tube bending equipment which has four heads for bending the tube and the carriage for moving the tube. The system consists of two frames for transporting each moving parts, high-frequency heating equipment for heating the tube in hot bending, control panel for inputting the job data operating, remote control unit for concetration and distribution of input/output, and the monitoring system which can establish unmanned operationby receiving the bending job data via LAN form a design teamwhich produces the job data and schedule based on master production plan and diagnoses bending data change, input, whole system status, and system malfunctions. By employing this system, 30% of production improvement was achieved was achieved comparing to the existing bending system.

  • PDF

The Development of Remote Monitoring & Control System using Modem Uninterruptible Power Supply (모뎀을 이용한 무정전 전원장치(UPS) 원격감시제어시스템 개발)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.445-447
    • /
    • 1997
  • In this paper a remote monitoring and control system using Modem for UPS (Uninterruptible Power Supply) is proposed. The conventional remote monitoring system for UPS is used to local remote monitoring system by RS232 or RS485 communication code. But recently. the system is changed to wide remote monitoring and control system using Modem for quick analysis of errors, correction of errors, report of errors and other user-friendly functions. In this study, we designed and develope system which is able to control UPS an monitor errors, statuses, actual values transmitted from UPSs of each site.

  • PDF

Application and evaluation of PD diagnostic algorithm for 3-phase in one enclosure type GIS (3상 일괄형 GIS 부분방전 진단 알고리즘 적용 및 평가)

  • Kim, Seong-Il;Choi, Young-Chan;Jung, Seung-Wan;Baek, Byung-San;Kwon, Joong-Lok;Hong, Cheol-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1374-1375
    • /
    • 2008
  • 본 논문은 3상 일괄형 GIS의 부분방전 진단을 위해 새롭게 개발한 진단 알고리즘에 관한 것이다. 진단 알고리즘 개발을 위해, 먼저 실시간 부분방전 데이터를 행벡터 및 열벡터로 구성하고 각각의 벡터에서 통계 특징량 및 질감 특징량을 추출하였다. 다음으로 이들 특징량을 GA-NN(Genetic Algorithm - Neural Network) 학습에 적용하여 진단 알고리즘을 구성하였다. 또한 진단 알고리즘의 위상독립성은 부분방전 신호의 위상변화에 관계없이 진단결과가 일치하는 것을 확인함으로써 검증하였다. 개발한 진단알고리즘의 실증 평가를 위해, 부분방전이 발생되고 있는 국내 3상 일괄형 GIS 변전소에 적용하였다. 적용 결과, 위상에 관계없이 부분방전 발생원을 정확히 진단함을 확인하였고, 이를 통해 개발 알고리즘의 우수성을 입증하였다.

  • PDF

Torque ripple reduction for High power Induction Motor driven by DTC (DTC로 구동되는 대용량 유도전동기의 토크리플 저감법)

  • Park, Young-Min;Yun, Jae-Hak;Han, Gi-Jun;Choi, Se-Kyung;Jung, Myung-Kil;Lee, Se-Hyun;Lee, Kyo-Beum;Song, Joong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.369-371
    • /
    • 1999
  • A torque ripple minimization technique is proposed for high power induction motors driven by 3-level inverters with switching frequency of inverter switching elements limited around 500Hz level. It is noted that conventional DTC algorithms with torque ripple minimization scheme are devised for applications with relatively high switching frequency above 2-3kHz. A new DTC algorithm, especially for low switching frequency inverter system, illustrates relatively reduced torque ripple characteristics all over the operating speed region. Simulation results show effectiveness of the proposed control algorithm, and associated experimental works will be presented in the final paper.

  • PDF

A developement of Remote Monitoring & Control System using SNMP for UPS (SNMP를 이용한 UPS 원격 감시 제어 시스템)

  • Lee, Soo-Byeong;Kim, Dong-Uk;Kim, Yun-Poong;Shin, Hyun-Joo;Ryu, Seung-Pyo;Min, Byoung-Gwon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.381-383
    • /
    • 1999
  • In this paper a remote monitoring and control system using SNMP(Simple Network Management Protocol) for UPS (Uninterruptible Power Supply) systems is proposed. The local remote system by RS-232 or RS-485 communication code or the wide remote system by modems is used for conventional remote monitoring & control system for UPSs. But recently because of communication cost and long distance the system is changed to remote control systems through internet and information communication network. And serial communication method by RS-232 or RS-485 is used between agent and UPSs. In this study. we designed and developed the system which is able to control UPSs and to monitor errors. statuses and actual values transmitted from UPS through internet.

  • PDF

The Control of Parallel Operation for Static UPSs (Static UPS 병렬운전 제어)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

Proper Orthogonal Decomposition of Pressure Fluctuations in Moonpool (문풀 내 압력 변동에 대한 POD 분석)

  • Lee, Sang Bong;Woo, Bum;Park, Dong Woo;Ahn, You Won;Go, Seok Cheon;Seo, Heung Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.484-490
    • /
    • 2012
  • Experiments of circulating water channel and two dimensional numerical simulations were performed to investigate the fluctuating characteristics of pressure in moonpool. Based on the quasi-two dimensional characteristics of pressure fluctuations disclosed by the spatial cross-correlations, the numerical results showed qualitatively good agreement with experimental data. Proper orthogonal decomposition was employed to the spatial distributions of pressure fluctuations in order to find the first and second modes of fluctuations. The first mode of pressure fluctuations showed that the fluctuating characteristics of pressure were related to the behaviors of vortical structures. The velocity fluctuations were conditionally averaged to make clear that the coherent structures were responsible for the pressure fluctuations in moonpool.

Study on New Candidate Coating Materials to Challenge Rudder Cavitation Damage

  • Lee, H.I.;Han, M.S.;Baek, K.K.;Lee, C.H.;Shin, C.S.;Chung, M.K.
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.274-282
    • /
    • 2008
  • Ships' hull is typically protected by a combination of protective coating system and electrical cathodic protection system, which has been an economical and effective measure for ship's hull to date. However, ships' rudder and adjacent hull areas are known to be subjected to premature corrosion damages, which require more frequent coating repair than other hull areas. Conventional organic coating system for ship's hull has been known only to remain intact just for 2~3 months on the rudder and adjacent area, especially for the fast-going ships such as container carriers or naval vessels. In this study, special organic/inorganic coating materials, which are commercially available, were tested in terms of cavitation resistance as an alternative to existing rudder & hull protection system. Both standard ultrasonic tester and in-house developed ultra water jet test method were employed as a means to evaluate their performance against cavitation induced damages. Additionally, the overall cost evaluation and workability at actual shipyard were discussed.