• 제목/요약/키워드: Heating tank

검색결과 206건 처리시간 0.025초

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

원전의 공기조화설비(HVAC) 상실사고 분석방법 (Analysis of Loss of HVAC for Nuclear Power Plant)

  • 송동수
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.90-94
    • /
    • 2014
  • 본 논문은 원자력발전소의 내환경기기검증(EQ)을 위한 HVAC 과도분석 방법에 대한 내용을 기술하고 있다. 분석 대상 격실은 비안전관련 HVAC 계통에 의해 공급되는 격실 중에 원자로 안전정지를 담당하는 중요기기가 위치한 구역/격실을 선정하였다. 그리고 해당 HVAC 계통이 공급되는 건물별로 HVAC 과도시 온도조건을 분석하였다. 본 분석을 위해서 GOTHIC 전산코드를 사용하였다. 온도분석 결과는 원자로 보조건물 환기계통(DVN)의 W315/W415 격실에서 $82.2^{\circ}C$로 가장 높은 온도값을 나타내며, 제어봉구동장치 전원공급건물 및 보조급수펌프실(DVG) 계통의 W229 (Auxiliary feedwater pump room) 격실에서 $52.7^{\circ}C$, 기기냉각건물 환기계통(DVI)의 전 격실에서 $42.9^{\circ}C$, 전기건물 주환기 계통(DVL)의 L207 (Hot workshop) 격실에서 $57.3^{\circ}C$를 각각 나타났다. 이러한 온도값은 일반적인 원전의 기기검증 제한값인 $171^{\circ}C$이하이므로 내환경검증 요건을 만족하는 온도이다.

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

무여과순환수 탱크 이용 Tilapia의 고밀도 사육실험 (High Density Tilapia Culture in a Recirculating Water System without Filter Bed)

  • 김인배
    • 한국수산과학회지
    • /
    • 제16권2호
    • /
    • pp.59-67
    • /
    • 1983
  • 1982년 5월 18일부터 10월21일까지 부산수산대학 양어장에서 Tilapia를 여과조가 없는 순환사육시설에 고밀도로 수용하고 그 성장도, 사료효율, 수질 등 이에 관련되는 문제점 등을 검토하였다. 그리고, 또 이 실험결과에 입각하여 사업적 생산타당성을 아울러 제시하였다. 수질에 있어서는 수온 $22.8{\sim}29.1^{\circ}C$의 범위였고, 암모니아는 일반적으로 10ppm을 약간 넘는 수준이었다. 사육탱크내에서 녹색 plankton을 유지할려고 수차에 걸쳐서 녹색수를 주수하였으나 그때 마다 $2{\sim}3$일 내로 투명해졌다. 이것은 아마 Tilapia의 plankton포식에 의한 것 같고, Tilapia의 고밀도 수용하에서는 녹색수유지는 곤란할 것으로 생각되었다. 사료효율은 처음의 쇠약기를 제외하고는 F.C. $0.9{\sim}l.2$의 범위였고, 평균은 1.1이었다. 이 때 사용한 사료는 일부는 단백질함량 $25\%$의 연구실제조 사료였고 대부분은 동 $39\%$의 시중상품잉어사료였다. 성장중 자체 번식은 완전히 억제되었다. 이것은 밀도효과라고 인정되었으며, 사육중 밀도는 최하 $1m^2$당 10kg 최고 40.7 kg 범위였다. 공간이용효과는 대단히 높았다. 1일순생산이 가장 높았던 제3실험구의 경우는 1일평균 6.206kg 였으므로 연간 1ha당 3235톤의 순생산에 해당된다. 이 때의 평균수온은 $28.4^{\circ}C$였고 암모니아농도는 10ppm정도였다. 총 6개의 실험구중 실험초 $1m^2$당 15kg이상 실어서 사육한 것을 대상으로 사업적 경제성검토를 하였다. 이번 실험에 사용한 시설전부(8탱크 총면적 $56m^2$)를 이용했다고 가정하면 200일 사육에 평균 5,639kg 생산된다고 계산되어 경영적 측면에서도 타당성이 있는 것으로 결론지어졌다.

  • PDF

Myriococcum albomyces가 생산하는 Cellulase에 관한 연구 (Studies on the Cellulase produced by Myriococcum of albomyces)

  • 정동효
    • Applied Biological Chemistry
    • /
    • 제14권1호
    • /
    • pp.59-97
    • /
    • 1971
  • Myriococcum albomycesf가 생산하는 섬유소 분해효소군에 관한 연구로서 호소생산배지 및 조효소의 성질을 규명하고 몇 가지 효소군으로 정제한바 다음과 같은 결과를 얻었다. 1. 밀기울 고채해양의 각 효소 활성은 쌀겨고체배양 및 탈지대두박고체배양의 그것보다 강하였다. 2. 밀기울진탕, 쌀겨진탕배양 및 대두박진탕배양등은 상기의 고체배양보다 각 효소의 활성이 우수하였다. 3. $45^{\circ}C$에서 배양한 것이 배양기의 종류에 관계없이 $37^{\circ}C$$50^{\circ}C$에서 배양한 것보다 각 효소의 활성이 강하였다. 4. CMCase는 무기 질소원보다 유기 질소원을 첨가하므로서 더욱 생성이 촉진되었다. 5. 기본밀기울진탕배양기에 CMC, Avicel, 여지분말 등의 indncer를 첨가 하므로서 각 효소활성은 $1.5{\sim}3$배나 증가되었다. 6. CMC와 Avicel을 inducer로 하여 jar formentor에서 배양할 때 작 효소의 활성은 대개 5일째에 최고에 달하였다. 7. Cellulae 조효소의 최적 pH는 $4.0{\sim}4.5$, pH안정성은 $3.5{\sim}8.0$이였다. 그리고 최적온도는 $65^{\circ}C$ 부근으로 다른 사상균의 cellulase에 비하여 높으며 온도안정성도 $60^{\circ}C$에서 120분으로 거의 실활되지 않았다. 8. 조효소의 활성은 $Ca^{++}$, $Mg^{++}$으로 부활되며, $Hg^{++}$, $Cu^{++}$, $Ag^{+}$는 강한 저해체였다. 그리고 투석으로 약간 그 활성이 저하되었다. 9. 배양액을 여과하고 황산암모니움 분획, DEA-E-sephadex A-25, Amberlite CG-50 및 hydroxy-apatite column chromatography로 Avicel, CMC, 여지 분말에 대하여 활성이 다른 4개의 fraction을 분리 하고 이를 cellulase fraction I, fraction II-a, fraction II-b 및 fraction III라고 명명하였다. 10. 이들 4개의 fraction은 전기 영동, 초원심상 및 자외선흡수 등으로 보아서 단일의 단백질로 생각되었다. 11. Fraction I은 Avicelase활성이 강하고, fraction II-a는 cellobiase 활성이 강하였다. 그리고 fraction II는 CMCase 활성이 강하였으며, fraction III는 CMC 점도감소 활성이 강하였다. 12. 섬유소질을 각 fraction으로 가수분해한 최종산물은 cellobiose 및 glucose였다. 그리고 fraction I과 fraction II-a는 Avicel을 협동적으로 분해하였다. 13. Fraction I의 최적 pH 5.5, fraction II-a는 pH 5.0, fraction II-b는 pH 4.0, fractionIII는 pH $4.0{\sim}4.5$이며, 각 fraction의 pH 안정성은 pH $3.0{\sim}7.0$이였다. 14. Fraction I의 최적온도는 $50^{\circ}C$, fractionII-a는 $55{\sim}60^{\circ}C$, fraction II-b 는 $60^{\circ}C$, fraction III는 $55^{\circ}C$이며 각 fraction의 열안정성은 $55^{\circ}C$ 부근에서 120분으로 거의 실활되지 않고 fraction II-a는 $60^{\circ}C$에서도 특별히 안정하였다. 15. Fraction I과 fraction II-b 활성은 $Ag^{++}$, $Hg^{++}$에 의하여 저해되며 $Ca^{++}$, $Mg^{++}$으로는 부활되었다.

  • PDF