Effect of heat pump performance improvement by use of thermal tank with temperature seperation plate (격판분리 축열조의 히트펌프 성능개선 효과)

  • Moon, Jongpil;Lee, Sunghyoun;Kwon, Jinkyung;Kang, YounKoo;Lee, Sujang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.80.1-80.1
    • /
    • 2011
  • This study was carried out in order to estimate the effect of heat pump performance by use of thermal tank with 3 seperation plates which were able to divide thermal tank into 3 chambers that have different temperatures levels. For testing the effect of developed thermal tank which was installed for supplying the heat to the paprika greenhouse in Jinju city. The volume of thermal storage tank was designed for $110m^3$ which was able to cover 30% of heating capacity. The temperature difference was 3 degree Celcius between high temperature and low temperature when only heating circulation was made from heat pump to thermal tank. but 5.5 degree Celcius difference was made when heating circulation of heat pump to thermal thank and hot water supplying circulation of thermal tank to greenhouse was done simultaneously. As a result of this study showed that COP of heat pump was increased by 15% or more than that of using normal thermal tank because heat pump was able to take 3 ~ 5 degree Celcius lower thermal thank water constantly.

  • PDF

Thermal environment analysis of greenhouse using Thermo-tracer (Thermo-tracer를 이용한 온실의 열환경 분석)

  • 이석건;이종원;이현우;김란숙
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

A Development of Automation System and a Way to use Efficiency of Solar Energy System in Greenhouse -Study on temperature variation of soil heating in greenhouse- (시설원예용 태양열 시스템의 효율적 이용과 자동화 장치 개발(1) - 시설재배 지중가온의 온도변화 연구 -)

  • 김진현;김철수;명병수;최중섭;구건효;김태욱
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.54-60
    • /
    • 1998
  • 시설재배의 생육은 지상부의 온도에 주로 영향을 받지만, 토양이 저온일 경우에는 양분의 흡수가 불량하고, 토양미생물의 활동이 떨어진다. 특히 세근의 발달이 억제될 뿐만 아니라 코르크화가 촉진되고, 정식후 묘의 활착이 지연되어 토양수분의 흡수가 불량해지므로 생육이 저하된다. (중략)

  • PDF

Combustion Qualities of Waste Tire Oil as Substituting Light Oil for Greenhouse Heating (시설농업난방 경유대체유로서 폐타이어오일의 연소 특성)

  • 김영중;유영선;강금춘;이건중;윤진하
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.481-488
    • /
    • 2000
  • This study was initiated in order to find alternative fuel substituting for light oil the most common fuel for heating greenhouse. The tire oil used in this research was produced by pyrolysis process, one of the final products besides steel string and carbon black in which waste tires as a form of chopped pieces broken by shredding machine are heated up to 200~30$0^{\circ}C$ with maximum restraining of oxygen supply. In order to justify light oil equivalent qualities in tire oil combustion characteristics were defined in the way of comparing kinetic viscosities in the wide range of temperature flame sizes and exhaust gas components in the various combustion conditions. We found that kinetic viscosity of tire oil was lower than light oil by 1 to 2 cSt in the temperature range showing better flowing mobility in the fuel line of the burner and no significant difference in flame size between the two oils in the all combustion treatments. However much more NO and SO$_2$ were detected from the exhaust gases of tire oil than light oil combustions. In fact tire oil contains more nitrogen and total sulfur, by 25 times and 40 times respectively than light oil according to the composition analysis. Tolerable limit for SO$_2$discharge amount defined by the national air pollution standards is under 540ppm so tire oil combustion satisfies the requirement though. It is desirable if sulfur and nitrogen filtering process shall be added in the tire oil production line. Except the exhaust gas components all greenhouse heating qualities of tire oil including hot air temperature are very identical to those of light oil.

  • PDF

Development of Thermal Storage System in Plastic Greenhouse(II) -Thermal performance of solar greenhouse system for hydroponic culture- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템의 개발(開發)에 관(關)한 연구(硏究)(II) -수경재배용(水耕栽培用) 태양열(太陽熱) 온실(溫室) 시스템의 열적(熱的) 성능(性能)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.123-133
    • /
    • 1990
  • Thermal performance of a solar heating plastic greenhouse designed for a hydroponic system was studied. The system was constructed with the air-water heat exchanger and thermal storage tank that were combined with hydroponic water beds. Experiments were carried out to investigate the daily average heat stored and released in thermal storage tank, average solar energy collection efficiency, average coefficient of performance, average oil reduction factor of thermal storage system, and the heat transfer coefficient during the nighttime in plastic greenhouse. The results obtained in the present study are summarized as follows. 1. Daily average heat stored in thermal storage tank and released from the thermal storage tank was 1,259 and $797KJ/m^2$ day, respectively. 2. The average solar energy collection efficiency of thermal storage tank was 0.125 during the experiment period. And the average coefficient of performance of thermal storage system in plastic greenhouse was 3.6. 3. The average oil reduction factor of thermal storage system and the heat transfer coefficient during the nighttime in plastic greenhouse were found to be 0.52 and $4.3W/m^2\;hr\;^{\circ}C$, respectively.

  • PDF

Analysis of Surplus Solar Energy in Greenhouse Based on Setting Temperature (설정온도별 온실내 잉여 태양에너지 분석)

  • Yoon, Yong-Cheol;Kown, Sun-Ju;Kim, Hyeon-Tae;kim, Young-Joo;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.195-206
    • /
    • 2012
  • This study is about an analysis of surplus solar energy by important greenhouse types as well as setting temperature different by using Typical Meteorological Year data which was secured in order to provide basic data for designing an optimum thermal storage system to accumulate surplus solar energy generating in greenhouses during the daytime. Depending on the setting temperatures of $15{\sim}19^{\circ}C$ for greenhouse heating during day and night, surplus heat amounts were varied at the rate of about $0.2{\sim}6.9%/4^{\circ}C$ with some variations according to the greenhouse types and regions. On the other hand, the variations of supplemental heat requirements were about $29.7{\sim}50.0%/4^{\circ}C$. Depending on the setting temperatures for greenhouse ventilations(low $25{\sim}29^{\circ}C$ and high $27{\sim}31^{\circ}C$), surplus heat amounts were varied at the rate of about $-9.9{\sim}-35.6%/4^{\circ}C$ in auto-type greenhouse. But in single-type greenhouses, they were about $-5.1{\sim}-13.4%/4^{\circ}C$. There were not significant changes in supplemental heat amounts depending on setting temperatures of ventilation for both greenhouse types and regions.

Development of Dehumidifier for Protected Horticulture (시설원예용 제습기 개발)

  • Yon K.S.;Kang G.C.;Kang Y.K.;Ryou Y.S.;Kim Y.J.;Paek Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.110-113
    • /
    • 2005
  • Relative humidity of air In the greenhouse has to be maintained at 70 to 80 percents to provide a better growth condition of crops. To control relative humidity of air in the greenhouse, a dehumidifier functioning by refrigeration cycle was designed and manufactured in this study. And, results of its performance test in the greenhouse site were reported. The developed dehumidifier has separated condenser and evaporator in the heat exchanger part in order to increase dehumidifying capacity at a low temperature condition. When the conditions of incoming air into the dehumidifier were temperature of $15\~25^{\circ}C$ and relative humidity of $0\~95\%$, quantity of condensed water per hour, ie, dehumidification rate was $4.7\~7.0\;kg/hr$. Relative humidity difference was not greater than 5 percents at various locations in the greenhouse due to proper distributing of dehumidified air through vinyl duct. Thermal energy output from the developed dehumidifier was about 8,5000 kcal/hr that was 7 percents of maximum greenhouse heating load of 10 a.

Derivation of Standard Air Temperature Curve for Greenhouse Heating Design and its Application to Heating Degree Hour (온실의 난방설계를 위한 표준기온곡선 유도 및 난방 Degree Hour에의 적용)

  • 김문기;손정익;남상운;유인호;이동근
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1992.12a
    • /
    • pp.21-22
    • /
    • 1992
  • 온실의 난방에 필요한 난방기기의 용량 및 연료소비량을 합리적으로 추정하기 위해서는 난방설계용 외기조건, 즉 표준기상 데이터가 필요하다. 그러나, 현재 국내에는 건물의 냉난방 설계를 위한 표준기상 자료가 대도시 지역의 일부에 대하여만 발표되어 있다. 이것은 농업시설에 대해서는 적용이 불가능하므로 농업 시설 설계를 위한 개략적인 표준기상 데이터의 선정이 요망된다. (중략)

  • PDF

Occurrence of White Rust and Growth of Chrysanthemum 'Baekma' by Control of Relative Humidity with Night Ventilation and Heating in the Greenhouse (국화 '백마'의 시설재배에서 야간 환기와 난방에 의한 상대습도 조절에 따른 흰녹병 발생과 생육)

  • Yoo, Yong Kweon;Roh, Yong Seung;Nam, Byung Cheol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.845-859
    • /
    • 2016
  • This study was conducted to examine the effect of nighttime ventilation and heating on changes in temperature and humidity, the occurrence of white rust, and growth of standard chrysanthemum (Dendranthema grandiflorum) 'Baekma' in a greenhouse. For the ventilation treatments, the mean nighttime humidity in the control greenhouse, which had a closed side window, was higher (94.5%), but the humidity in the natural and natural+fan ventilation treatments was lower (74.3% and 72.8%, respectively). The rate of occurrence of white rust at 34 days after treatment was 100, 98.3, 75.6, and 43.3% for the control, fan ventilation, natural ventilation, and natural+fan ventilation treatments, respectively. The number of infected leaves and telia were the lowest in the natural+fan ventilation treatment compared with the other treatments. The growth of the chrysanthemum 'Baekma' was significantly suppressed in the control because of the occurrence of white rust and high humidity, while plant height, number of leaves, stem diameter, and fresh weight were the greatest in the natural+fan ventilation treatment. For the heating treatments, the mean nighttime temperature of the control (RH 95% heating), which was heating and held at 95% humidity, was $18.4^{\circ}C$, while the temperature of the heating treatment, which was held at 70% relative humidity (RH 70% heating) was $25.8^{\circ}C$. The rate of occurrence of white rust (34.4%), number of infected leaves (0.9), and telia (1.0) were the lowest in the RH 70% heating treatment compared with the other heating conditions. Also, the RH 70% heating treatment showed the best growth in terms of plant height, stem diameter, number of leaves, and fresh weight. Therefore, the natural+fan ventilation and RH 70% heating treatments were effective for the control of white rust and the growth of standard chrysanthemum 'Baekma' in a greenhouse.

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.