• Title/Summary/Keyword: Heating effect

Search Result 2,281, Processing Time 0.028 seconds

An Investigation on the Effect of Duration of Sunshine on the Heating Energy of Apartment Houses (일조시간이 아파트 난방에너지 소비량에 미치는 영향에 관한 조사연구)

  • Lee Jong-Won;Hwang Hye-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.277-284
    • /
    • 2005
  • The purpose of this study is to analyze the effect of sunshine on the heating energy consumption of apartment houses by a field investigation in Haeundae, Busan. In the field, heating energy consumption of every household is researched by reading a calorimeter and the duration of sunshine of every household is calculated by Sunlight V1.0. Then, the duration of sunshine and heating energy are done regression analysis by SPSS 10. According to this study the apartment houses by orientation spend more energies order of east, west, southeast, southwest, and south. When apartment houses are same orientation, there is difference of $29{\sim}58\%$ in heating energy consumption by the duration of sunshine. And the heating energy consumption in worst condition of sunshine increases $67\%$ on the best condition of sunshine.

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Analysis of Heating Energy in a Korean-Style Apartment Building 3 : The Effect of Room Condition Settings (한국형 아파트의 난방에너지 분석 3 :실내설정조건의 영향)

  • Park, Yoo-Won;Yoo, Ho-Seon;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.722-728
    • /
    • 2005
  • The present paper deals with heating energy estimation in Korean-style apartments, paying special attention to the effect of room condition settings. Two types of heating modes are considered: continuous single-zone and scheduled multi-zone. In the latter, zones during unoccupied periods remain unconditioned. Also analyzed are sensitivities in heating energy with respect to the air change rate and the set temperature. The energy use is estimated with TRNSYS 15, a dynamic load calculation program. Heating energy for the actual residential condition (1.0 ACH and $24^{\circ}C$) appears to be nearly the same as that for a typical design standard (1.5 ACH and $20^{\circ}C$). The air change rate affects heating energy as sensitive]y as the set temperature. For all the simulated cases, the scheduled multi-zone heating mode is more energy-efficient than the continuous single-zone. Heating energy depends appreciably on the shading factor. It is expected that considerable heating energy for apartment houses can be saved by employing a multi-zone mode along with appropriate control devices.

Experimental Study on Thermal Sensation Evaluation in Heating(part I: Emotion & Sensibility Image Evaluation by Indoor Temperature Change in Heating) (실내 난방시 온열쾌적성 평가에 관한 연구(part I;실내 난방시 실온변화에 따른 감성이미지 평가))

  • 한남규;금종수;김형철;김동규;김창연
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.05a
    • /
    • pp.41-46
    • /
    • 2003
  • In recently, Is inhabiting more than 70% indoors during a day in case of company employee and ordinary people which is looking at usual business. Therefore Thermal comfort of human body about indoor temperature and air flow acting very heftily. When intestine temperature is fallen for external low temperature and air flow in winter in case enter into heated room feel comfort by effect of temperature and feel comfort or discomfort by room heating condition gradually. Therefore it is important that grasp thermal comfort about temperature and air flow in heating to keep continuous comfort in indoor dwelling. Temperature and thermal comfort factor of emotion & sensitivity image exert fair effect since heating middle although thermal comfort change greatly effect on sensation about temperature at actuality heating early. Need much study yet in vantage point of emotion & sensitivity although much study were held about thermal and comfort sensibility and when heat in existing research until now. Therefore this study is targeting that evaluate thermal comfort through introduction of estimation method by emotion & sensibility image real and synthetic sensibility about thermal environment that is becoming winter heating.

  • PDF

Thermodynamic Analysis of a Double-Effect Absorption Heating System Using Water-LiBr-LiSCN Solution with Solar Evaporator Heating (증발기 열원으로 태양열을 이용하며 LiSCN+LiBr 수용액을 사용하는 흡수식 2중효용 난방시스템의 열역학적 해석)

  • Won, Seung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.27-35
    • /
    • 2005
  • In this paper, a thermodynamic analysis was performed to provide design data for a double-effect absorption heating system with water-LiBr-LiSCN mixture which utilizes solar energy as evaporator heat source. In addition, a comparative study of the water-LiBr-LiSCN mixture against the water-LiBr pair was conducted by a computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water-LiBr-LiSCN mixture than for the water-LiBr pair, and FR is lower for the former.

Dependence of Self-heating Effect on Width/Length Dimension in p-type Polycrystalline Silicon Thin Film Transistors

  • Lee, Seok-Woo;Kim, Young-Joo;Park, Soo-Jeong;Kang, Ho-Chul;Kim, Chang-Yeon;Kim, Chang-Dong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.505-508
    • /
    • 2006
  • Self-heating induced device degradation and its width/length (W/L) dimension dependence were studied in p-type polycrystalline silicon (poly-Si) thin film transistors (TFTs). Negative channel conductance was observed under high power region of output curve, which was mainly caused by hole trapping into gate oxide and also by trap state generation by self-heating effect. Self-heating effect became aggravated as W/L ratio was increased, which was understood by the differences in heat dissipation capability. By reducing applied power density normalized to TFT area, self-heating induced degradation could be reduced.

  • PDF

Effect of the Heating Rate on the Microstructure and Fracture Toughness of Silicon Nitride Ceramics (소결시의 승온속도가 질화규소 요업체의 미세조직과 파괴인성에 미치는 영향)

  • 이상훈;이재도;김도연
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1227-1232
    • /
    • 1995
  • Effect of heating rate on the microstructure of the silicon nitride ceramics has been investigated. The specimens with composition of 92Si3N4-6Y2O3-2Al2O3 (in wt%) were sintered at 176$0^{\circ}C$ under 127 kPa for 3h in N2 atmosphere at various heating rates from 1 to 10$0^{\circ}C$/min. The grain size of larger than 2${\mu}{\textrm}{m}$ and less than 1${\mu}{\textrm}{m}$ were measured and compared for the specimens. Regardless of heating rate, grain size of all the specimens showed bimodal distributions and the fracture toughness remained in the range of 5.53~5.72 MPa.m1/2. However, the aspect ratio of the grains of diameter above 2${\mu}{\textrm}{m}$ increased with the heating rate while their grain size and volume fraction decreased.

  • PDF

Analysis of Line Heating Using Induction Heating (유도가열을 이용한 선상가열 해석방법)

  • Yun, Jin-Oh;Yang, Young-Soo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.128-134
    • /
    • 2007
  • Induction heating process includes magnetic and thermal situations. In order to analyze the induction heating, material properties depending on temperature are considered. In this paper, three dimensional analysis of induction heating process for moving inductor is analyzed using moving coordinate. The skin effect is confirmed inside the steel plate in the electro-magnetic analysis. The heat generation at the initial state is different from that at the quasi-stationary state. Therefore, material properties depending on temperature must be considered. The results of finite element analysis agree well with the experimental temperature results.

  • PDF

Numerical Analysis on Effect of the Environmental Velocity for Circular Heating Source with Heat Generation (열생성을 가진 원형발열체의 외부 유속의 영향에 대한 수치해석)

  • Bae, K.Y.;Ji, M.K.;Chung, H.S.;Chung, H.T.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • This paper represents the numerical analysis on effect of the environmental velocity for circular heating source with heat generation. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, a circular heating source was studied through numerical analysis on several conditions of unsteady state, beat generation and environmental velocity. The temperature distributions at steady state is appeared as a non-linear pattern with variations of environmental velocity. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

A Study on the Optimum Line Heating Condition for Straightening a Thin Plate Welded Structure (박판재 용접 구조물의 선상 가열 교정에서 최적 조건의 선정에 관한 연구)

  • Park, Jun-Hyoung;Kim, Jae-Woong
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of this study is to establish the optimum line heating condition to straighten the excessive bending distortion of a thin plate welded structure. For it, the extensive FEA and experiments were performed to evaluate the effect of heat source, heating speed and position on the straightening of a thin plate welded structure. In accordance with the results obtained by FEA and experiments, the straightening effect of line heating was strongly depends on the variables used in this study. With the results, the optimum line heating condition was established by using the response surface method and verified through comparing it with the numerical analysis result.