• Title/Summary/Keyword: Heating Zone

검색결과 304건 처리시간 0.026초

고주파 유도가열된 조선용 강판의 기계적 특성 연구 (A Study on the Mechanical Properties of Heated Plates by Induction Heating System)

  • 현충민;이명수;조시훈;장태원
    • Journal of Welding and Joining
    • /
    • 제32권1호
    • /
    • pp.47-52
    • /
    • 2014
  • Due to of high intensity, lower noise and easy controllability of the heat, induction heating system became well known. Induction heating method has been suggested as substitute for the gas heat source and adopted in the automation of curved hull forming system. In this study, an investigation was accomplished to find the effects on the change of material properties when the induction heating was applied on the mild steel plate. Plates were heated using weaving method to get sufficiently heat affected zone and then cooled with water or in the air. The mechanical properties of the heated plate were evaluated. As results, the tensile test, impact test and microstructures satisfied the class rule.

공동주택의 한국형 온돌시스템 적용에 관한 연구 (A Study on the Korean Ondol-System Application in Apartment Houses)

  • 안민희;최창호;유기형;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

납착조건이 14K 금납을 이용한 티타늄 납착부의 인장강도에 미치는 영향 (EFFECT OF SOLDERING CONDITION ON THE TENSILE STRENGTH OF TITANIUM SOLDER JOINT WITH 14K GOLD SOLDER)

  • 최정호;김태조;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.566-576
    • /
    • 1997
  • This study was performed to evaluate the tensile strength of solder joint in titanium and the wettability of 14K gold solder on titanium. Two pieces of titanium rod 30 mm in length and 3mm in diameter were butt-soldered with a 14K gold solder using the electric resistance heating under flux-argon atmosphere, the infrared heating under argon atmosphere, and the infrared heating under vacuum-argon atmosphere. A tensile test was performed at a crosshead speed of 0.5 mm/min, and fracture surfaces were examined by SEM. To evaluate the wettability of 14K gold solder on titanium, titanum plates of a $17{\times}17{\times}1mm$ were polished with #80-#2000 emery papers, and the spreading areas of solder 10 mg were measured by heating at 840 * for 60 seconds. The solder-matrix interface regions were etched by the solution of 10% KCN-10% (NH4)2S2O8, and analyzed by EPMA. The results obtained were summarized as follows ; 1. The maximum tensile strength was obtained when the titanium surface was polished with #2000 emery paper and soldered using the electric resistance heating under flux-argon atmosphere. Soldering strengths showed the significant difference between the electric resistance heating and the infrared heating(p<0.05). 3. The fracture surfaces showed the aspect of brittle fracture, and the failure developed along the interfaces of solder-matrix reaction zone. 4. The EPMA data for the solder-matrix interface region revealed that the diffusion of Au and Cu occurred to the titanium matrix, and the reaction zone showed the higher contents of Au, Cu and Ti than others.

  • PDF

난방도일 기반 대한민국 행정구역별 기후존 구분 기준 정립에 관한 연구 (A Study on the Classification Criteria of Climatic Zones in Korean Building Code Based on Heating Degree-Days)

  • 노병일;최재완;서동현
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.574-580
    • /
    • 2015
  • Climatic zone in building code is an administrative district classification reflecting regional climatic characteristics. Use of Degree-Days is a fundamental method that can be used in various building design codes, analysis of building energy performance, and establishment of minimum thermal transmittance of building envelopes. Many foreign countries, such as the USA, the EU, Australia, Italy, India, China, etc., have already adapted climatic zone classification with degree-days, precipitation or amount of water vapor based on the characteristics of their own country's climate. In Korea, however, the minimum requirements for regional thermal transmittance are classified separately for the Jungbu area, Nambu area and Jeju Island with no definite criterion. In this study, degree-days of 255 Korean cities were used for climatic zone classification. Outdoor dry-bulb temperature data from the Korea Meteorological Administration for 1981~2010 was used to calculate degree-days. ArcGIS and the calculated degree-days were utilized to analyze and visualize climatic zone classification. As a result, depending on the distribution and distinctive differences in degree-days, four climatic zones were derived : 1) Central area, 2) Mountain area of Gyeonggi and Gangwon provinces, 3) Southern area, and 4) Jeju Island. The climatic zones were suggested per administrative district for easy public understanding and utilization.

Experimental Research of an ECR Heating with R-wave in a Helicon Plasma Source

  • Ku, Dong-Jin;An, C.Y.;Park, Min;Kim, S.H.;Wang, S.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.274-274
    • /
    • 2012
  • We have researched on controlling an electron temperature and a plasma collision frequency to study the effect of collisions on helicon plasmas. So, we have designed and constructed an electron cyclotron resonance (ECR) heating system in the helicon device as an auxiliary heating source. Since then, we have tried to optimize experimental designs such as a magnetic field configuration for ECR heating and 2.45GHz microwave launching system for its power transfer to the plasma effectively, and have characterized plasma parameters using a Langmuir probe. For improving an efficiency of the ECR heating with R-wave in the helicon plasma, we would understand an effect of R-wave propagation with ECR heating in the helicon plasma, because the efficiency of ECR heating with R-wave depends on some factors such as electron temperature, electron density, and magnetic field gradient. Firstly, we calculate the effect of R-wave propagation into the ECR zone in the plasma with those factors. We modify the magnetic field configuration and this system for the effective ECR heating in the plasma. Finally, after optimizing this system, the plasma parameters such as electron temperature and electron density are characterized by a RF compensated Langmuir probe.

  • PDF

인공신경망을 적용한 선상가열시 강판의 곡률변형 추정 (Application of Neural Network to the Estimation of Curvature Deformation of Steel Plates in Line Heating)

  • 전병재;김현준;양박달치
    • 한국해양공학회지
    • /
    • 제20권4호
    • /
    • pp.24-30
    • /
    • 2006
  • Different methods exist for the estimation of thermaldeformation of plates in the line heating process. These are based on the assumption of residual strains in the heat-affected zone, known as the method of inherent strains, or simulated relations between heating conditions and residual deformations. The purpose of this paper is to develop a simulator of thermal deformation in the line heating, using the artificial neural network. Curvature deformations for the plate-forming are investigated, which can be used as a prime deformation parameter in the process. The curvature of plates are calculated using the approximation of plate surface by NURBS. Line heating experiments for 11 specimens of different thickness and heating conditions were performed. Two neural networks predicting the maximum temperature and curvature deformations at the heating line are studied. It was concluded that the thermal deformations predicted by the neural network can be used in a line heating simulator, which is considered an attractive and practical alternative to the existing methods.

실리콘러버 기반의 히터제작에 관한 연구 (A Study on the Fabrication of Heater based on Silicone Rubber)

  • 홍정오;홍재택;최신형
    • 산업과 과학
    • /
    • 제2권2호
    • /
    • pp.9-15
    • /
    • 2023
  • 실리콘러버히터는 플렉시블하기 때문에 평면, 곡면, 입체적인 형태에서도 직접 접착이나 피가열물에 넣어 설치할 수 있다. 현재의 가열방식은 열이 필요하지 않은 영역 또는 위치를 무시하고 피가열물체 전체를 가열하여 필요한 온도로 상승시키기 때문에 일부분만을 부분집중 가열할 수 없었다. 멀티히팅존을 이용하면 피가열물체 전체를 가열하는 것보다는 공정에 따라 열이 필요한 부분만 집중가열하기 때문에 열이 필요한 장소마다 적은 전기용량으로 발열량을 다르게 적용하여 국소 위치별로 빠르게 가열할 수 있고, 열에너지를 줄일 수 있다. 본 연구에서는 열융착이 필요한 영역에서 균일한 온도 또는 온도 차이가 발생하도록 다중 가열영역 구조내의 부분집중 영역에 대한 온도 및 가열 시간을 측정한다. 최적의 전력밀도 범위 결정 및 전기용량을 감소하기 위해 멀티히팅존 구조로 제작된 실리콘러버히터의 안전성을 알아본다. 이와 같이 다중가열방식으로 실리콘러버히터를 제작하면 다중집중 가열기술을 모든 가열공정에 이상적으로 적용할 수 있다.

알루미늄 熔接構造物의 變形橋正을 위한 Autogeneous GTAW의 適用 可能性 硏究 (A Feasibility Study on the Use of Autogeneous GTAW for Correction of Distortions in Welded Aluminum Alloy Structures)

  • 하용훈;강춘식;유순영
    • Journal of Welding and Joining
    • /
    • 제10권1호
    • /
    • pp.20-34
    • /
    • 1992
  • Characteristics of two correcting methods, a new Autogeneous GTAW heating (TIG) method and the conventional GMAW bead-on plate welding(MIG) method, for distorted aluminum fabrication structures were studied. As a result of microscopic study of Autogeneous GTAW heating and GMAW bead-on plate welding areas, porosities in weld metal and surface cracks in local heating zone were found. Through the mechanical tests, it was verified that porosities decrease tensile strength and surface of distortion, angular displacement and transeverse shrinkage were measures and compared. In order to investigate changes of material properties in heating area and cause of defects such thermal stresses were calculated by ADINA. Through the computations of transient thermal stresses and microscopic observation of fracture surface, thermal stress was found to be the cause of crack during Autogeneous GTAW heating.

  • PDF

극저온에서 풍속의 영향에 따른 발열기자재의 최적설계 (Optimum Design of the Heating Equipment by Influence of Wind Speed at Cryogenic Temperature)

  • 조현준;윤원영
    • 품질경영학회지
    • /
    • 제48권3호
    • /
    • pp.463-479
    • /
    • 2020
  • Purpose: The purpose of this study is to evaluate the performance of heating equipments by implementing the extreme environment in which ships navigating the ice zone are exposed and to study and apply the experimental method to infer the optimized design for each factors. Methods: It is required to verify by analysis and experiment how the environment with low temperature and wind speed implemented through the test facility affects the heating walk-way and The optimum design of the heating walk-way in that extreme environment is derived using the Taguchi technique. Results: The results of this study are as follows; It was found the effect on the condition of each factor and derive optimized conditions that satisfy the performance condition of the heating walk-way in extreme use environment. Conclusion: Ships operating in Polar waters require reliable and durable facilities for all environments during sailing.

On the material properties of shell plate formed by line heating

  • Lim, Hyung Kyun;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권1호
    • /
    • pp.66-76
    • /
    • 2017
  • This paper is concerned with investigating the plastic material properties of steel plate formed by line heating method, and is aimed at implementing more rational design considering the accidental limit states such as collision or grounding. For the present study, line heating test for marine grade steel plate has been carried out with varying plate thickness and heating speed, and then microscopic examination and tensile test have been carried out. From the microscopic, it is found that the grain refined zones like ferrite and pearlite are formed all around the heat affected zone. From the tensile test results, it is seen that yield strength, tensile strength, fracture strain, hardening exponent and strength coefficient vary with plate thickness and heat input quantity. The formulae relating the material properties and heat input parameter should be, therefore, derived for the design purpose considering the accidental impact loading. This paper ends with describing the extension of the present study.